SAFETY WARNINGS      

 

 

Read and Understand all Safety Warnings before using Air Compressor 

 

Hazard Level 

  

 

 

Flying objects 
 

 

  

Warning 

Risk of Unsafe 
Operation 

  

 

  

  

  
 
 
 

 

  

Caution 

Risk of Damage 
to Air 
Compressor or 
Property 

 
 

 
 

 
 
 
 

Potential of Hazard

 

 
Serious injury may occur from 
loose debris being propelled at 
high speeds from the compressed 
air stream. 
 
 
 
 
 
 

 
Serious injury or death may occur 
to you or others if air compressor 
is used in an unsafe manner. 
 
 
 
 
 
 
 

 
 
Failure to transport or operate the 
air compressor properly may result 
in major repair expenses. 
Oil leaks will damage carpets, 
painted surfaces, flooring, and 
other items. 

 
 
 
 
 
 

How to Avoid Hazard 

 

 
Always wear OSHA required “287” safety 
glasses to protect the eyes during 
operation of the air compressor.  Never 
point the air stream or tools at any point 
of your body, other people, or animals.   
Always turn off the air compressor and 
drain tank pressure completely before 
attempting maintenance, or attaching air 
tools. 
 

 
Review and understand all instructions 
and warnings in your owner’s manual.  
Know how to stop the air compressor.  Do 
not operate until you are thoroughly 
familiar with all of the controls.  Do not 
operate the compressor if fatigued or 
under the influence of alcohol or drugs.  
Stay alert while operating the 
compressor, and pay close attention to 

he task at hand. 

t

 
 
Check oil levels daily and maintain proper 
oil levels.  Always run compressor in a 
level, secure position, that keeps it from 
tipping or falling during use.  Do not 
operate without an air filter or in a 
corrosive environment. 
Always transport in a level position and 
use protective mats to keep truck beds 
clean, etc.  Check drain bolts regularly 
and do not overfill machinery with oil. 
 
 
 

Please note that this product may not be equipped with a spark arresting muffler.  If the compressor is operated 
around flammable materials or agricultural crops, brush, forests, and grasslands an approved spark arrestor must be 
installed, maintained, and in good working order. An approved spark arrestor is legally required in the State of 
California under sections 4442 and 4443 of the California Public Resources Code Statute section /30050.   
 
This product contains chemicals, including lead, known to the state of California to cause cancer, birth defects, and 
other reproductive harm.  Always wash hands after handling this product. 

Содержание portable air compressor

Страница 1: ...RGE AIR FOR BREATHING PARTS Genuine ROLAIR replacement parts are sold nationwide through a network of authorized dealers and service centers Please contact the dealership where your air compressor was purchased or our factory Customer Service Department if you need help troubleshooting obtaining parts or locating an authorized ROLAIR service representative To order replacement parts 1 Give compres...

Страница 2: ...here You ll save time and expense by including this reference information when requesting service or replacement parts Place Date of Purchase Volts Model HZ Serial HP With the tank gauge at 0 PSI and air line s disconnected close drain valve s and record the amount of time it takes to build tank pressure on the space provided Periodically test your air compressor against this pump up time to deter...

Страница 3: ...e service from your new air compressor If you have any additional safety or operating questions after reading this manual please contact your distributor or our customer service department Do not remove or paint over any of the warning decals attached to the compressor Definitions Safety Warnings Safety symbols are used throughout this manual to alert you to potentially hazardous situations The fo...

Страница 4: ... pressure ratings causing them to explode or fly apart How to Avoid Hazard Never inhale compressed air directly from the pump receiver or from a breathing evice connected to the air compressor d Operate compressor only in a well ventilated area Use a respirator device and follow the manufacturer s recommendations for their spray equipment Keep compressor at least 25 eet away from spray equipment f...

Страница 5: ...d adequate fuse rotection p Never operate air compressor in wet conditions or outdoors when it s raining Disconnect power and bleed tank pressure before servicing Do not operate with damaged power cord or with protective electrical overs removed c Do not allow electric cords to lay in water Do not touch plug with wet hands Do not pull on electric cord to isconnect from the outlet d Any electrical ...

Страница 6: ...muffler during operation and even after compressor is shut down for sometime Serious injury can result from attempting to lift an object that is too heavy How to Avoid Hazard Never operate the air compressor without protective belt guards installed Replace damaged protective covers or guards mmediately i Always unplug air compressor and drain air tanks completely before attempting any repairs or p...

Страница 7: ...ot operate until you are thoroughly familiar with all of the controls Do not operate the compressor if fatigued or under the influence of alcohol or drugs Stay alert while operating the compressor and pay close attention to he task at hand t Check oil levels daily and maintain proper oil levels Always run compressor in a level secure position that keeps it from tipping or falling during use Do not...

Страница 8: ...rt and stop automatically within the settings of the pressure switch which are typically 105 130 PSI Do not attempt to stop the compressor by unplugging the power cord To stop simply move the lever to the Off position The lever operates a relief valve that dumps off head pressure and allows the compressor to restart without load the next time it is used 4 REGULATOR WORKINGPRESSURE To adjust the ou...

Страница 9: ... not alter the factory top RPM setting The engine idle speed is factory set and controlled by a black plastic Philips head screw on the carburetor A slight increase to the idle speed setting may be required when operating in colder temperatures Turn screw clockwise in turn increments to increase the idle speed If the idle speed setting is too low premature fouling of spark plug will occur 13 COLD ...

Страница 10: ...T CLEAN CHANGE INTAKE ELEMENTS ON A REGULAR BASIS The ingestion of dirt into the pump and engine is the primary cause of premature wear Pay special attention to the intake filters Check intake filters daily 5 USE LONGER PROPERLY SIZED AIR HOSE RATHER THAN EXTENSION CORDS If an extension cord must be used please refer to the chart below for the proper gauge and maximum length that can be used The u...

Страница 11: ...ore compressor in a warm dry location perform maintenance as indicated in manual BELT DRIVEN ELECTRIC Follow same procedures described for use of direct drive electric compressor Use the drain valve located on the pump aftercooler for cold starting purposes Your belt driven electric compressor may be set up for dual control operation See figure 1 for instructions to switch operation from start sto...

Страница 12: ...sting marks that indicate the minimum and maximum acceptable levels of oil Our belt driven pumps have a sight gauge located on the outside of the crankcase to make the task even easier Always maintain the oil level at the maximum mark on the dipstick or to 2 3 full in the sight gauge Do not operate the pump with an inadequate or excessive amount of oil The cost of failures which occur due to incor...

Страница 13: ... felt muffler and cause gas engine to slow down to idle speed If pilot valve does not unload as tank pressure approaches 130 P S I G slowly turn top end setting 4 counterclockwise until pilot starts to unload prematurely at 100 P S I G turn top end setting 4 clockwise in turn increments tap down on the internal rod at toggle attachment and repeat until desired top end setting is reached If pilot v...

Страница 14: ...ppropriate parts Loose belts Adjust belt tension Knocking noise Internal pump problem Take unit in for service Poor ventilation Relocate compressor Improper pump rotation Rewire for correct rotation Overheating compressor Internal pump problem Take unit in for service Thermal overload tripped Locate and push reset button Reset physically broken Replace overload reset Loose motor leads or electrica...

Страница 15: ...r purpose and of any other obligations and or liabilities on the part of Associate Engineering Corporation Associate Engineering Corporation neither assumes nor authorizes any other person to assume for it any other obligations or liability in connection with or with respect to any compressor Associate Engineering Corporation shall in no event be liable neither for any consequential incidental or ...