VIEW MEDIUM/MAXIMUM HUMIDITY DAILY/HOURLY VALUE

Press either the REC MED or the REC MAX key

(key lamp flashes)

.

Either the average or the maximum humidity value
as recorded in the last 24 hours will be displayed.

Note:
Daily recordings are stored up to 99 days.

Hourly recordings are stored up to 60 hours

;

afterwards the oldest  record is automatically deleted by the new one.

Press the 

-

  key to select and display one of the previous

hours records 

(max 60)

.

The following message will be displayed.
Press REC MED to display the average humidity value of
the selected hour.
Press REC MAX  to display the max humidity value of the
selected hour.

Press the 

-

  key to select and display one of the previous

days records 

(max 99)

.

The following message will be displayed.
Press REC MED to display the average humidity value of
the selected day.
Press REC MAX  to display the max humidity value of the
selected day.

Example with 1 day ago

To erase memory keep + key for longer than 3 sec.
Before cleaning the memory a CLEA message will be displayed.

HOW TO ERASE CYCLE RECORDINGS (NEW CYCLE START-UP)

Press the - key to display the current day 

(d=)

 

and the current hour (h=

of cycle.

(on firts day

 

d= 0).

HOW TO DISPLAY THE DAY OF CYCLE

Example with 1 hour ago

These settings refer to the operation mode of the system and must be made on
initial startup. Press - / + at the same time for at least one second: the message
C.O.S.t. will be displayed.
Press than repeatedly REC MAX until the message regarding the chosen variable
is displayed (see table below) : value of variable and message will be displayed.
Press + or - to set a new value and then press REC MAX to confirm.
The next system constant will then appear.
You can press REC MAX for at least 2 seconds to exit and return to the Run Mode.

COST  PROGRAMMING (System constants)

.

s

s

e

M

e

u

l

a

V

g

n

i

n

a

e

M

e

t

o

N

A

L

A

.

t

"

0

e

m

i

t

y

a

l

e

d

m

r

a

l

a

s

d

n

o

c

e

S

*

u

H

.

d

A

%

0

)

%

0

2

+

/

-

(

t

n

e

m

t

s

u

j

d

a

r

o

s

n

e

s

y

t

i

d

i

m

u

H

Alarm led is blinking during all the delay alarm time.

MANUAL MODE

In some start-up conditions may be useful to work in "hand" mode.
Power off the processor, push + key and keep it pressed giving power on:
HAnd message will be displayed (release now  +  key).
Press  + (1  is displayed) and press REC MAX to activate relay.
You can press REC MAX key for at least two seconds to escape and return to the
Run Mode.

This processor is already programmed with the following (variable) settings.
To return to these settings at any time you may:

Power off the processor, press REC MAX key and keep it pressed giving power
on: boot  message will be displayed (release now REC MAX key).

H.SEt = 80%
COST 
value are shown in COST paragraph.

PRESET PROGRAMS (Bootstrap)

Example humidity average= 80%