PNI PNI-ZM101-EV Скачать руководство пользователя страница 5

 

-

 

The number of packets received. 

-

 

The calculated PER in %. 

-

 

The maximum and minimum RSSI values in this PER test 

RSSI is received signal strength indication. For the detail of the RSSI value, 

please refer UZ2400 RF chip’s datasheet.  

1.1.2

 

Continuous TX / Pseudo Noise 

 
The menu item “3” initiates the modulates RF transmission. The data carried 

are pseudo random numbers.   

1.1.3

 

Continuous RX / Pseudo Noise 

 
The menu item “4” initiates the carrier RF transmission.  

1.1.4

 

RX mode 

 
The menu item “5” initiates the receiver mode.  

1.1.5

 

IDLE mode 

 
The menu item “6” sets the UZ2400 into the IDLE mode.  

1.1.6

 

Sleep mode 

 
The menu item “7” sets the UZ2400 into the Deep Sleep mode. 

1.1.7

 

Standby mode 

 
The menu item “8” sets the UZ2400 into the Standby mode. 

1.1.8

 

RF Channel Setting 

 

Содержание PNI-ZM101-EV

Страница 1: ...1 User Manual PNI ZM101 EV ZigBee TM ready Wireless Network Evaluation Board Using the UZ2400 RF chip And the 78K0R KE3 Microcontroller...

Страница 2: ...am such as Hyperterminal is required to interact with the sample program and a NULL MODEM cable is needed to connect PC s COM port to evaluation kit s RS232 DB9 connector In case no COM port is availa...

Страница 3: ...1 Flow control None Local echo Off Line feed No 1 1 RF test sample application Two PNI ZM101 EV boards are required to conduct this test J5 to J8 is used to setup the board 4 LSB address Set one unit...

Страница 4: ...p back function and in the menu of the transmitter board the board with short address 0001 press 1 to setup PER test The first prompt ask you to input the destination short address you may input 0002...

Страница 5: ...m 3 initiates the modulates RF transmission The data carried are pseudo random numbers 1 1 3 Continuous RX Pseudo Noise The menu item 4 initiates the carrier RF transmission 1 1 4 RX mode The menu ite...

Страница 6: ...hat means 0dBm For detail of output power register please refer to UZ2400 s datasheet 1 1 10 Resetting RF The menu item A allows you to reset the UZ2400 chip registers 1 2 MAC Sample program Text Mess...

Страница 7: ...7 Now you shall find the following message in the hyperterminal if not reset the evaluation board...

Страница 8: ...rt the end device When successfully associated with the coordinator the end device will be assigned a short address by the coordinator and the return statur shall also be 00 Do the same step for each...

Отзывы: