2 / 4
1) The weekday is fixed from Monday to Sunday(l -7), each schedule have 4 periods(1-4). Each press
of PRG button PRG button can into next item setting.
2) Press PRG and hold for 3 seconds, the minutes flash(A), change the values by up and down button.
3) Press PRG,the temp. Digital flash(C),change the values by up and down button.
4) Press PRG the PRG. Digital(D) to change to PRG 2 automatically. The minutes of PRG2 flash.Repeat
the same method to set the time and temp. Of each period.
5) After schedule done, press Return Button to main display.
Example:
Advance Setting
Turn off the sender, long press “MENU” button until the screen is lit, press + or – to set
value.
Press “PRG” button to enter to next step.
Time Adjust and Mode Temp. Setting
Menu
Description
Range
Default value
01
Temp. Calibration
-8 ~ +8
℃
(in 0.5
℃
increments)
0
℃
02
Switching Sensitivity
0.5 ~ 5
℃
0.5
℃
03
Frost Protection Temp.
3~10
℃
/ - -
(
Function OFF
)
- -
04
Open window detect function (OWD)
00(Function OFF) / 01(Function ON)
00
05
OWD Detect Time
2~30 min
15 min
06
OWD Drop temp.
(
within detect time
)
2-4
℃
2
℃
07
OWD Delay time select (Return
to previous working status)
10-60 min
30 min
Address
code
Pairing Code
/
4 digits
Software
Software version
/
/
Monday to Friday
Saturday
Sunday
Period
1
2
3
4
1
2
3
4
1
2
3
4
Time
6:30
8:00
18:00
22:30
8:00
10:00
18:00
23:00
9:00
12:00
19:00
23:45
Temp.
21°C
18°C
21°C
16°C
21°C
21°C
21°C
16°C
23°C
21°C
16°C
21°C