background image

   

  WARNING:

 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, 

OR INJURY TO PERSONS, OBSERVE THE FOLLOWING.

SWH3000 12152014

Page 1

SLIM WALL 

OWNER’S GUIDE

USE AND CARE MANUAL 

MODEL SWH3000

 

For Customer Assistance 
CALL 1-800-325-6952

• Read all instructions carefully before installation
• This cooler must be connected to 120Volt AC, 60 Hz (cycle) 

power only. NOTE: Improper voltage will void the pump 
and/or motor warranties and may cause serious personal 
injury or property damage.

• This cooler must be plugged into a GFCI protected 

receptacle, which has been properly installed in accordance 
with all local and national codes. If you are not sure that 
the receptacle is GFCI protected, consult with a qualified 
electrician.

• This cooler is equipped with a power cord having an 

equipment grounding conductor and grounding plug. Do 

NOT

 attempt to defeat this safety device by removing the 

grounding pin.

• Do 

NOT

 step on or roll over power cord with heavy or sharp 

objects. Do 

NOT

 operate if plug or cord is damaged in 

any way. If the unit is damaged or malfunctions, do 

NOT

 

continue to operate.

• Remove the plug from the electrical receptacle by pulling on 

the plug and not the cord.

• Always disconnect electrical power to unit before 

attempting to work on or service your cooler.

• Do 

NOT

 operate near open containers of flammable liquid 

or gases.

• Do 

NOT

 operate with evaporative pad(s) removed.

• Use of extension cords is 

NOT

 recommended.

Congratulations: You have purchased a product of superior 
performance and design, which will give the best service 
when properly operated and maintained. 
This guide was designed to provide you with the 
information needed to install, operate, inspect, maintain and 
troubleshoot your Slim Wall evaporative cooler.
The first section, Installation and Start-Up, gives details for 
installation. The second section, Maintenance, contains 
operational and maintenance instructions to aid in keeping 
your unit in good working order, while Troubleshooting 
includes information to help diagnose and repair commonly 
encountered problems.

• Do 

NOT

 operate this cooler (fan motor) with any solid-state 

speed control device.

• Do 

NOT

 operate with back panel or outlet grille removed. 

Do 

NOT

 place fingers or any other objects inside the blower 

section. Serious risk of personal injury or property damage 
can occur.

• 

NEVER

 wash your cooler cabinet with a garden hose. Water 

may harm motor and pump.

• Do 

NOT

 locate or operate cooler near exhaust or vent pipes 

as odor or fumes may be drawn into unit.

• Your warranty does 

NOT

 cover shipping damage. Report all 

shipping damage at once to store making delivery.

• For future reference, record the serial number and purchase 

date of your evaporative cooler here:

Serial #
Purchase Date:
Place of Purchase:

IMPORTANT: Read the complete installation instructions 
before proceeding with installation

.

     

WARNING:

 THE USE OF ANODE DEVICES, 

CHEMICAL ADDITIVES, OR COOLER CLEANER 
TREATMENTS IN THIS COOLER WILL VOID 
WARRANTY.

1-999-2490

Содержание SWH3000

Страница 1: ...Use of extension cords is NOT recommended Congratulations You have purchased a product of superior performance and design which will give the best service when properly operated and maintained This gu...

Страница 2: ...qualified to do so CAUTION Disconnect all electrical power to the cooler before attempting to install open or service your cooler Even while routinely inspecting or servicing the inside the cooler can...

Страница 3: ...anges must be made Consult a qualified professional before making structural changes to the wall CAUTION When cutting or drilling into the wall do NOT damage electrical wiring or other hidden utilitie...

Страница 4: ...6 1 8 below the bottom of the duct cutout Ensure the bracket is installed level and is centered in relation to the duct cutout Pre drill the holes and attach the brackets using the included lag screws...

Страница 5: ...over drain bushing push drain bushing through bottom of cooler and tighten nut Screw plastic overflow standpipe into the drain bushing and tighten hand tight to prevent leakage Where conditions allow...

Страница 6: ...ermal overload switch that will shut the motor and or the pump off if it overheats The motor and or pump can restart automatically when they cool down Page 5 To verify and check out the cooler install...

Страница 7: ...INSPECTION CAUTION Do not allow pump to fall over and become submerged water will damage pump motor Clean water pump and hose assembly as follows 1 Unplug power supply cord from wall receptacle remov...

Страница 8: ...pad and will remove more stubborn scaling 4 If necessary replace with new rigid media pads available only from your rigid media dealer Aspen expanded paper or other types of evaporative cooling pads...

Страница 9: ...et screen clogged 1 Clean or replace media pads 2 Check water distributor system 3 Locate and free obstruction 4 Clear debris from trough 5 Clean or replace pump 6 Check for leaks and correct 7 Turn o...

Отзывы: