![PMFoundations State Machine Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/pmfoundations/state-machine/state-machine_user-manual_1569457004.webp)
Controls
1.
Gate In
2.
Retrig In
For keyboard controller with retrigger output, this will reset the envelope to the attack phase.
3.
> A, > D, > S, > R
CVs for ADSR sections. Standard 0 to 10V but small negative voltages will shorten the A,D and R
times. Negative S will produce a sustain level below 0V.
4.
Linear/Exponential
Linear will shorten the envelope as well as change the shape.
5.
Gate/Trig
Gate: When gate held, envelope follows ADS stages. When gate released, R stage begins.
Trig: When positive edge of gate signal, envelope starts A stage. The envelope continues with
the R stage if the gate is released. If the gate is held, the ADS stages will be followed until the
gate is released, in which case the R stage is entered immediately.
6.
Loop
Gate/Trig must be on Trig. Press Loop to start self-cycle/LFO mode. Cycle will start/stop/change
shape depending on settings of ADSR. There is no sustain in loop mode if there is no "held" key.
The curve follows AR only.
If a key is held down the A and D curves are followed.
7.
Envelope CV out
8.
State outputs
A - On when attacking
EOA - positive edge of gate signal resets to 0, goes high at end of A.
EOA (P) - short pulse only at start of EOA
D - On when decaying
EOD - resets to 0 when rising attack signal hits sustain level, goes high at end of D.
EOD (P) - short pulse only at start of EOD
S - On when sustaining
R - On when releasing
EOR - positive edge of gate signal resets to 0, goes high at end of R.
EOR (P) - short pulse only at start of EOR.
9.
EOD or EOR cycle
Set Gate/Trig to Trig. Patch EOD into Gate. A and R change shape, S changes base voltage.