PMFoundations State Machine Скачать руководство пользователя страница 4

 

 

Controls 

 

1.

 

Gate In 

2.

 

Retrig In 
For keyboard controller with retrigger output, this will reset the envelope to the attack phase. 

3.

 

> A, > D, > S, > R 
CVs for ADSR sections.  Standard 0 to 10V but small negative voltages will shorten the A,D and R 
times.  Negative S will produce a sustain level below 0V. 

4.

 

Linear/Exponential 
Linear will shorten the envelope as well as change the shape. 

5.

 

Gate/Trig 
Gate: When gate held, envelope follows ADS stages.  When gate released, R stage begins. 
Trig: When positive edge of gate signal, envelope starts A stage.  The envelope continues with 
the R stage if the gate is released.  If the gate is held, the ADS stages will be followed until the 
gate is released, in which case the R stage is entered immediately. 

6.

 

Loop 
Gate/Trig must be on Trig. Press Loop to start self-cycle/LFO mode.  Cycle will start/stop/change 
shape depending on settings of ADSR.  There is no sustain in loop mode if there is no "held" key.  
The curve follows AR only. 
If a key is held down the A and D curves are followed. 

7.

 

Envelope CV out 

8.

 

State outputs 
A - On when attacking 
EOA - positive edge of gate signal resets to 0, goes high at end of A. 
EOA (P) - short pulse only at start of EOA  
D - On when decaying 
EOD - resets to 0 when rising attack signal hits sustain level, goes high at end of D. 
EOD (P) - short pulse only at start of EOD 
S - On when sustaining 
R - On when releasing 
EOR - positive edge of gate signal resets to 0, goes high at end of R. 
EOR (P) - short pulse only at start of EOR. 

9.

 

EOD or EOR cycle 
Set Gate/Trig to Trig. Patch EOD into Gate.  A and R change shape, S changes base voltage. 