0507060080/011113/H | SIF-700/900/1200/1500/1800/1900/2000 -|SF 7000/9000/12000/15000/18000/19000/20000
EN - 3
ENGLISH
Using this manual
This manual is intended to be used as a work of reference for
professional, well trained and authorised users to be able to
safely install, use, maintain and repair the product mentioned
on the cover of this document.
Pictograms and symbols
The following pictograms and symbols are used in this manual:
Text indicators
Listings indicated by "-" (hyphen) concern enumerations.
Listings indicated by "•" (bullet point) describe steps to perform.
Service and technical support
For information about specific adjustments, maintenance or
repair jobs which are not dealt with in this manual, please
contact the supplier of the product. He will always be willing to
help you. Make sure you have the following specifications at
hand:
- product name
- serial number
These data can be found on the identification plate.
1.1
Identification of the product
The identification plate contains, among other things, the
following data:
- product name
- serial number
- supply voltage and frequency
- power consumption
1.2
General description
The fan is used for extracting fumes and gases which are
released during the most common welding processes. The fan is
mounted in a sound absorbing case with inspection cover and is
used in an extraction system with filter unit.
The fan can be used in the following configurations:
- multiple arm systems with a central filter unit
- modular extraction hoods with a central filter unit
- push-pull systems
1.3
Product combinations
The fan can be used with the following products:
- central filter system
- system control panel
1.4
Options and accessories
The following products can be obtained as an option and/or
accessory:
- mounting frame
- silencer 0°
- silencer 90°
- reducers metric to imperial
- SIF/SF Outdoor; suitable for outdoor installation
1.5
Technical specifications
1.6
Fan curves
1.7
Ambient conditions
2.1
Components
The extraction fan is a radial fan with straight blades. The inlet
is on the side; the outlet is on top. The fan consists of the
following main components:
A Extraction fan
B Inlet opening with adapter
C Outlet opening with adapter
D Sound absorbing case with inspection cover (left or right)
PREFACE
TIP
Suggestions and recommendations to simplify
carrying out tasks and actions.
ATTENTION!
A remark with additional information for the user. A
remark brings possible problems to the user’s
attention.
CAUTION!
Procedures, if not carried out with the necessary
caution, could damage the product, the workshop or
the environment.
WARNING!
Procedures which, if not carried out with the necessary
caution, may damage the product or cause serious
personal injury.
WARNING!
Denotes risk of electric shock.
WARNING!
Important warning to prevent fire.
1
INTRODUCTION
Motor design
IE3
Connection voltage
400-690V/3ph/50Hz
Speed of revolutions
2850 rpm
Power (kW/HP) and nominal current (A):
- SIF-700 / SF 7000
- SIF-900 / SF 9000
- SIF-1200 / SF 12000
- SIF-1500 / SF 15000
- SIF-1800 / SF 18000
- SIF-1900 / SF 19000
- SIF-2000 / SF 20000
3 kW
5,5 kW
7,5 kW
11 kW
15 kW
18,5 kW
22 kW
4 HP
7.5 HP
10 HP
15 HP
20 HP
25 HP
30 HP
55,77 A
10,1 A
13,9 A
20,1 A
27,1 A
33,3 A
39,9 A
Max. start/stops per hour
20
Insulation class
F with PTC
Protection class
IP 55
Dimensions
Weight
Refer to the available product data sheet for detailed
specifications.
Refer to the available product data sheet for the fan
curves.
SIF/SF
SIF/SF Outdoor
Min. operating temperature
5°C (41°F)
-20°C (-4°F)
Nom. operating temperature
20°C (68°F)
20°C (68°F)
Max. operating temperature
60°C (140°F)
60°C (140°F)
Max. relative humidity
80%
rain resistant
2
PRODUCT DESCRIPTION
Содержание SF 12000
Страница 48: ...0507060080 011113 H ...