![Plymovent PCU-1000 Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/plymovent/pcu-1000/pcu-1000_installation-and-user-manual_1569233005.webp)
0000101010/141119/2 PCU-1000/7500
EN - 4
PCU-7500
Operating
Automatic
Fully automatic
start/stop of the
exhaust fan by
PC-500
Manual
Continuously
running the
exhaust fan
Stop
Manual stop of the
exhaust fan
Max. power
5,5 kW ≤ PCU-7500 ≤7,5 kW @ 400 V
Stop delay timer
range
7 seconds - 6 minutes
Fig. 1.1 PC-500; pressure sensor
2
PRODUCT DESCRIPTION
2.1
Product components
The product consists of the following main components and
elements:
Fig. 2.1
A Fan indicator
B Automatic start/stop
C Manual stop
D Manual start
Fig. 2.1 PCU-1000/7500; front
Fig. 2.2
A Stop delay timer
Fig. 2.2 PCU-1000/7500; inside
2.2
Operation
PCU-1000/7500 is a control unit, with the possibility to both
manual and automatic control the exhaust fan up to 7.5 kW @
400 V/3ph/50Hz. When the control unit is in “automatic”
position, the exhaust fan starts by a signal from pressure
sensor PC-500 or any other similar external potential free
contact.
PC-500 reacts on pressure increase which occurs when a
vehicle starts and increases the pressure in the system.
When the engine is turned on, the pressure sensor reacts and
sends a signal to the control unit. Then, the control unit starts
the exhaust fan. The fan stops after the pre-adjusted after-run
time is out. The after-run time can be pre-adjusted between
7 sec. and 6 min. When the control unit is in “on” position
the exhaust fan runs continuously.
The control unit also has a position for manual stop
(see Fig. 2.1 C) of the exhaust fan. Observe that when the
control unit and the fan are stopped manually or automatically,
(stop delay time is out), and the motor is still running there is
a risk of exhaust gas leakage from the system and a risk that
the exhaust hose melts due to the temperature increase.
3
SAFETY INSTRUCTIONS
General
The manufacturer does not accept any liability for damage to
the product or personal injury caused by ignoring of the safety
instructions in this manual, or by negligence during installation,
use, maintenance, and repair of the product mentioned on the
cover of this document and any corresponding accessories.
Specific working conditions or used accessories may require
additional safety instructions. Immediately contact your supplier
if you detect a potential danger when using the product.
The user of the product is always fully responsible for
observing the local safety instructions and regulations.
Observe all applicable safety instructions and regulations.
User manual
- Everyone working on or with the product, must be familiar
with the contents of this manual and must strictly observe
the instructions therein. The management should instruct the
personnel in accordance with the manual and observe all
instructions and directions given.
- Do not change the order of the steps to perform.
- Keep the manual with the product.
33 mm
1/8” NPT
M3 x 20
A