![Plymovent MobilegoPlus Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/plymovent/mobilegoplus/mobilegoplus_installation-and-user-manual_1569254008.webp)
0000111659/140921/C MobileGo
7
Component Action
Frequency:
every X months
X=6
X=12
Filter unit
Housing
Clean the outside with a
non-aggressive detergent
X
Clean the inside with an industrial
vacuum cleaner and remove dust
from the filter compartment
X
Check sealing material of the
door. Replace if necessary
X
Extraction
fan
Check for encrusted particles.
Clean if necessary
X
Mains cord
Check for damage. Repair or
replace if necessary
X *)
Extraction arm
Tubes
Clean the outside with a
non-aggressive detergent
X
Clean the inside thoroughly
X
Flexible
hoses
Check for cracks or damages.
Replace if necessary
X
Hood
Check the movement of the hood.
If necessary, adjust the friction;
refer to paragraph 6.3
X
Arm
movement
Check horizontal, vertical and
diagonal arm movement. If
necessary, adjust the friction;
refer to paragraph 6.3
X
*) Before every use
6.2
Filter replacement
The buzzer emits an acoustic signal when the
airflow is too low.
Make sure that:
-
the shut-off damper is open
- the extraction arm is not fully folded
When the buzzer still continues, you must replace the filter
cassette(s).
As the pre filter is smaller and becomes more quickly saturated
than the HEPA filter, you can replace the pre filter cassette
several times before you finally need to replace the HEPA filter
cassette.
Personal protective equipment (PPE)
Wear respiratory protection and protective
gloves when you replace the filter
cassettes.
WARNING
Do
not
replace the filter cassettes while the fan is
running.
WARNING
Do
not
shake out or (vacuum) clean the used filter
cassettes to avoid the release of particles.
6.2.1
Pre filter cassette
To replace the pre filter cassette, do the following.
• De-energize the unit.
• Open the back door (B).
•
Remove the pre filter cassette (A).
•
Dispose of the used filter cassette in accordance with state
or local regulations.
•
Put a new pre filter cassette in the unit. Make sure that the
arrow on the frame points downwards
4
.
• Close and lock the door.
Fig. 6.1
B
A
Replacement of the pre filter cassette
When the buzzer continues to beep after you have
replaced the pre filter cassette, it is time to replace
the HEPA filter cassette.
6.2.2
HEPA filter cassette
To replace the HEPA filter cassette, do the following.
• De-energize the unit.
• Open the back door (C).
•
Remove the pre filter cassette.
•
Slightly lift and remove the HEPA filter cassette (D).
•
Dispose of the used HEPA filter cassette in accordance with
state or local regulations.
•
Put a new HEPA filter cassette in the unit. The side pins (A)
exactly fit in the slits (B).
•
Put the pre filter cassette back in the unit. Make sure that
the arrow on the frame points downwards
5
.
• Close and lock the door.
Fig. 6.2
C
D
B
A
Replacement of the HEPA filter cassette
4.
The arrow indicates the airflow direction
5.
The arrow indicates the airflow direction. An incorrectly placed pre filter
cassette affects the filter lifetime.
Содержание MobilegoPlus