0000110292/010123/B MiniMan-100 | MiniMan-100 ATEX | MiniMan-100 TopGrade
6
Fig. 4.4
A
A
Connection of the litz wire to the duct
• Measure the earth connection between the hood and the
duct. The electrical resistance must be lower than 10 ohm.
ATTENTION!
If the electrical resistance is over 10 ohm, the litz
wire connection is not correct. In that case: make
sure that all litz wires from the hood to the duct are
interconnected.
Fig. 4.5
< 10 ohm
< 10 ohm
Earth connection
5
USE
Personal protective equipment (PPE)
During use, use PPE to avoid injury. This
also applies for persons who enter the work
area.
• Take the handle (ref. Fig. 2.1 I) of the hood to position it at
max. 300 mm (12 in.) above the source of pollution.
•
Make sure that the DAMPER-100 (shut-off valve), if any, is
open.
• Turn on the connected extraction fan or system.
• Start working.
•
If desired, partly close the valve to adjust the airflow.
• When the working position changes, move the nozzle to
the correct position in relation to the workpiece.
•
Turn off the connected extraction fan or system approx. 20
seconds after finishing the work.
A
C
B
A
C
B
A
C
B
A = max. 300 mm
(12 in.)
B = >300 mm
(12 in.)
C = >0 mm
(0 in.)
Fig. 5.1 A = Correct position of the hood (example: soldering)
6
MAINTENANCE
6.1
Periodic maintenance
The product has been designed to function without
problems for a long time with a minimum of
maintenance. In order to guarantee this some simple, regular
maintenance and cleaning activities are required which are
described in this chapter. If you observe the necessary caution
and carry out the maintenance at regular intervals, any
problems occurring will be detected and corrected before they
lead to a total breakdown.
WARNING!
Overdue maintenance can cause fire.
The indicated maintenance intervals can vary depending on
the specific working and ambient conditions. Therefore we
recommend to thoroughly inspect the complete product once
every year beside the indicated periodic maintenance. For this
purpose contact your supplier.
Component
Action
Frequency:
every X
months
X=3
X=6
Outside of
the arm
Clean with a non-aggressive
detergent
X
Flexible hoses Check for cracks or damages. Replace
if necessary
X
Inside of the
arm
Clean thoroughly
X
Arm
movement
Check the movement of the arm. If
necessary, adjust the friction; refer to
X
6.2
Arm adjustment
If the extraction arm, or a part of it, does not stay in the
desired position, you must adjust the friction.
• Determine which part of the arm needs more or less
friction;
- inner tube (ref. Fig. 2.1E): adjust friction joint A
- outer tube (ref. Fig. 2.1F): adjust friction joint B
- hood (ref. Fig. 2.1G): adjust joint C