0000300349/230420/0 MDB-Diluter PRO
21
Inside
ATTENTION
The buttons inside the Panel are for service
purposes only. You can control the entire system via
the HMI, therefore, the buttons inside the Panel are
not necessary for daily use.
G Button | START/STOP FAN
H Button | FILTER CLEANING
-
to activate an additional filter cleaning cycle
- to suppress the buzzer (push and hold for 5 seconds)
I Switch 0-1 | SERVICE MODE
- 0: normal mode
- I: to lock the touch screen of the HMI for service
purposes
Outside
Inside
C
A
B
A B
D
C
E
F
G H
I
C
A
B
A B
D
C
E
F
G H
I
Fig. 6.1 Control panel
6.1.2 HMI
Refer to the online user manual ControlPro for
extensive explanation about the HMI:
www.plymovent.com/manuals/controlpro
ControlPro/
HMI
EN
User manual
NL
Gebruikershandleiding
DE
Betriebsanleitung
FR
Manuel opérateur
ES
Instrucciones para el uso
www.plymovent.com/manuals/controlpro
0000112733/0
The online user manual is available in English
language only. Short user manuals (PDF format) in
other languages are in process. Contact your
supplier about the availability of the short user
manual in your own language.
6.2
Use
Depending on the specific configuration and system settings
on the HMI, you can activate the fan and cleaning system
manually or have the entire system run fully automatically.
6.2.1 HMI
The HMI shows the actual system status at all times.
To control the entire system via the HMI is self-explanatory.
6.2.2 Panel
Manually activated functions for service purposes only:
- Button START/STOP FAN (G)
- Button FILTER CLEANING (H)
29
30
7
MAINTENANCE
7.1
Periodic maintenance
The system has been designed to function without
problems for a long time with a minimum of
maintenance. In order to guarantee this some simple, regular
maintenance and cleaning activities are required which are
described in this chapter. If you obey the necessary caution
and carry out the maintenance at regular intervals, any
problems occurring will be detected and corrected before they
lead to a total breakdown.
The indicated maintenance intervals can vary depending on
the specific working and ambient conditions. Therefore, we
recommend to thoroughly inspect the complete system once
every year beside the indicated periodic maintenance. For this
purpose contact your supplier.
The maintenance activities in the tables below indicated by [*]
can be carried out by the user; other activities are strictly
reserved for well trained and authorized service personnel.
7.1.1 MDB-Diluter
WARNING!
Overdue maintenance can cause fire.
WARNING
Always fully
disconnect
the system from the mains
before you carry out maintenance jobs as
mentioned below. First read the maintenance
regulations at the beginning of this manual.
WARNING
Always disconnect the compressed air supply before
you carry out maintenance jobs.
Component
Action
Frequency:
every X months
X=3
X=6
Dustbin
Check level of dust and dirt
particles. Empty if necessary
(ref. par. 7.2)
X
1
X
1
1
Frequency
depends on
welding process
Air inlet
module
Clean the inside; refer to
par. 7.4
X
Housing
Make sure that there is no
air leakage
X
29.
You cannot stop/interrupt the filter cleaning cycle
30.
You cannot activate this button during the first 40 running hours of the system
and within 40 running hours after filter replacement, to maintain the protective
layer of precoat material on the filter cartridges