0000300349/230420/0 MDB-Diluter PRO
11
• Put the air inlet module
within 60 seconds
on the filter
module.
ATTENTION
Make sure that you install the rectangular openings
over the
filter compartment
.
Fig. 4.21
8x
9x
8x
Position of air inlet module
• Put 9x bolt M20x8 with 9x washer M8 into the cage nuts to
attach both components.
Fig. 4.22
8x
9x
8x
Air inlet module on filter module
4.5.3 End cap
The air outlet module comes with an end cap.
• Put an end cap on the open side of the air outlet module.
• Fasten it with self-tapping screws.
• Use duct tape to make the connection airtight.
4.6
Filter pressure hoses
Each filter module contains a pneumatic hose with a
T-connector.
•
Put each T-connector (D) in the back of each filter module.
• Connect the hoses in series.
• Put an end plug (A) in the last T-connector.
• Install the compressed air switch (B).
• Connect the loose end of the pneumatic hose to the
compressed air switch (B) via the T-connector.
• Install a compressed air regulator (CAR-KIT or similar) (C)
on the mounting frame. Set it to 5 bar.
• Install a pneumatic hose between the compressed air
switch (B) and the compressed air regulator (C).
ATTENTION
Make sure that the airflow direction through the
regulator is correct; this is indicated by the arrow
on the back side.
Fig. 4.23
+
+
SCP-MDB
+
A
D
+
+
SCP-MDB
A
D
E
C
B
+
G
F
H
C
B
Pressure hose
WARNING
Prevent damage to the cleaning mechanism. Make
sure that the compressed air is free from oil and
moisture (ref. ISO 8573-3 class 6).
4.7
Cover plates
• Make additional holes in the seals. They must correspond
with the holes in the filter module.
• (1) Remove the backing material of the seals.
• (2) Spray SealApplicator lubricant on the seals.
• (3) Put one
cover plate within 60 seconds on the filter
module.
•
(4) Attach the cover plate with the flange screws.
• Repeat this procedure for the remaining cover plates.
Fig. 4.24
2
3
1
Cover plates