![Plymovent Flex-Max FM-1520 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/plymovent/flex-max-fm-1520/flex-max-fm-1520_product-manual_1569283014.webp)
FM/USA+CAN/14/16
BSAB no: T0.31
Ser. no: FM/DS
Date: Sept-97
Replace: Jan-95
MAINTENANCE
INSTRUCTION
FLEX-MAX
B
3
A.
If the arm does not stay in the required position:
Tighten the brakes in the two joints with an allen-key.
Check once every six months.
B.
If the arm does not stay in the required position:
1 .
Loosen the hose at B.
2 .
Pull the extractor out to its full length and angle it horizontally. Loosen
the friction brake until the arm drops towards the floor. Tighten until it
no longer drops.
3 .
If the arm is difficult to move sideways or moves on its own sideways,
then adjustments must be made to the friction collar in the wallmounting
bracket. This is done by either loosening or tightening the Allen screw.
C.
If the outer arm will not stay in the required position:
1 .
Angle the outer arm horizontally. Loosen the friction brake until the arm
drops towards the floor. Tighten until it no longer drops.
D.
If the hood will not stay in the required position:
1 .
Loosen the hose at D.
2 .
Adjust the friction (see picture) until the hood will stay in the exact
position.