Plymovent CONTROLGO Скачать руководство пользователя страница 3

0000112607/010420/A ControlGo 

2

PREFACE

Using this manual

This manual is intended to be used as a work of reference for 

professional, well trained and authorised users to be able to 

safely install, use, maintain and repair the product mentioned 

on the cover of this document.

Pictograms and symbols

The following pictograms and symbols are used in this manual:

TIP

Suggestions and recommendations to simplify 

carrying out tasks and actions.

ATTENTION

A remark with additional information for the user. A 

remark brings possible problems to the user’s 

attention.

CAUTION

Procedures, if not carried out with the necessary 

caution, could damage the product, the workshop or 

the environment. 

WARNING

Procedures which, if not carried out with the 

necessary caution, may damage the product or 

cause serious personal injury. 

CAUTION

Denotes risk of electric shock. 

Text indicators

Listings indicated by “-” (hyphen) concern enumerations. 

Listings indicated by “•” (bullet point) describe steps to 

perform. 

Product indications / Abbreviations

Product type:  

Equals to:

 

- ControlGo/Panel  

Panel

 

- Control/SlaveBoard  

SlaveBoard

 

- MDB GO  

 

MDB

 

- SCS GO  

 

SCS

 

- MultiDust Bank   

MDB

INTRODUCTION

1.1 

Identification of the product

The identification plates contain, among other 

things, the following data:

 

- product name

 

- serial number

 

- supply voltage and frequency

 

- power consumption

1.2 

General description

ControlGo of Plymovent is an intelligent control panel, 

including the required connection cables. This system controls 

the compressed air valves of the connected filter system MDB 

or SCS and the connected extraction fan. 

1.2.1  Con MDB

Fig. 1.1

A  Filter system MDB

1

B  SlaveBoard

2

C  Panel [control panel]

D  Fan control equipment (refer to paragraph 1.3)

E  Extraction fan (refer to paragraph 1.3)

1.

  Shown: rear of the filter system

2.

  Integrated on the rear of each filter module

Fig. 1.1 

B C

D

E

A

Con MDB

1.2.2  Con SCS

Fig. 1.2

A  Filter system SCS

B  Panel [control panel]

C  Fan control equipment (refer to paragraph 1.3)

D  Extraction fan (refer to paragraph 1.3)

Fig. 1.2 

B

C

D

A

Con SCS

1.3 

Product combinations

1.3.1  Required products

To operate the system, selection of the following products is 

necessary: 

Extraction fan

 

- Plymovent SIF 

(Outdoor)

specific type and motor power 

depends on the configuration

Mounting frame

 

- Plymovent FRAME SIF

specific type depends on the 

selected extraction fan and 

configuration

Fan control equipment

Recommended way:

 

- Plymovent VFD/Panel

3

 

(frequency inverter) 

specific type depends on the 

selected extraction fan

Other options:

 

- Other type of frequency 

inverter (third party)

fan start/stop with optional 

alarm feedback only

 

- Star-delta switch

fan start/stop with optional 

alarm feedback only

 

- Other type of motor 

starter

e.g. Direct online (DOL)

3.

  Including main switch to de-energize the entire filter system, thus complying 

with CE safety requirements. Additionally needed: pressure transmitter 

PT-1000 or PT-2500.

Содержание CONTROLGO

Страница 1: ...www plymovent com Control panel CONTROLGO Installation and user manual EN...

Страница 2: ...ument and is therefore subject at any time to change or amendment and the right to change or amend is hereby expressly reserved The instructions in this publication only serve as a guideline for insta...

Страница 3: ...ControlGo of Plymovent is an intelligent control panel including the required connection cables This system controls the compressed air valves of the connected filter system MDB or SCS and the connec...

Страница 4: ...rtificates CE 1 6 Ambient conditions 1 6 1 ControlGo Panel Pressure sensors Ambient temperature internal external min nom max 0 C 32 F 20 C 68 F 50 C 122 F 20 C 4 F 20 C 68 F 50 C 122 F Max relative h...

Страница 5: ...n EN ISO 12100 1 is the use for which the technical product is suited as specified by the manufacturer inclusive of his directions in the sales brochure In case of doubt it is the use which can be ded...

Страница 6: ...es approuv es et sch mas lectrique des armoires en question ATTENTION Risque de tension lectrique Il pourrait tre n cessaire d installer un interrupteur principal pour mettre hors tension la machine a...

Страница 7: ...n wire A and the cable jacket B Heat shrink the shrink tube with a heat gun C C A B C B 15 Recommended cable specifications use cables with a max wire diameter 1 5 mm AWG 16 All cables 3 Put the wires...

Страница 8: ...0 IN 10 11 24V 12 IN 11 13 24V 14 IN 12 15 COM2 16 GND Digital input 6 12 1 24V 2 IN 6 3 24V 4 IN 7 5 24V 6 IN 8 7 24V 8 IN 9 9 24V 10 IN 10 11 24V 12 IN 11 13 24V 14 IN 12 15 COM2 16 GND Valves 1 24V...

Страница 9: ...SlaveBoard SlaveBoard including conduit conduit connectors M20 nuts 2x Tube clamp screw Due to the cable length you can only make horizontal and vertical connections It is not possible to make diagon...

Страница 10: ...he correct sequence start with the upper left filter module 1 address from left to right subsequently from top to bottom 24 The red module on the PC board Addressing sequence Address configuration pos...

Страница 11: ...rm signal from an external device27 start stop signal cable 4 alarm signal cable 5 remove the wire bridge from input IN 11 27 E g a welding robot or a timer Indicator LED s Valves Digital input 1 5 CA...

Страница 12: ...ressure sensor Remove the wire bridge from input IN 4 refer to Fig 4 6A Indicator LED s Valves Digital input 1 5 CAN Slave Digital input 6 12 Filter Pressure sensor Light tower Power Relay 1 Relay 2 2...

Страница 13: ...Push the START STOP FAN button ref Fig 6 1F to start the fan Push the button again to stop the fan Filter cleaning system 3 MDB only Push the FILTER CLEANING button ref Fig 6 1G to activate the filter...

Страница 14: ...tem continues to run 32 The system stops running G Black button FILTER CLEANING to activate an additional filter cleaning cycle to suppress the buzzer push and hold for 5 seconds 33 to reset the warni...

Страница 15: ...MODUS MODE DE SERVICE MODO SERVICIO EXTERNAL DEVICE EXTERN APPARAAT EXTERNES GER T DISPOSITIF EXTERNE DISPOSITIVO EXTERNO External device In the ALARM mode the fan system stops immediately 7 MAINTENA...

Страница 16: ...ective Repair or replace the fan motor connection Repair or replace the fan control equipment NO COMPRESSED AIR GEEN PERSLUCHT KEINE DRUCKLUFT ABSENCE D AIR COMPRIM FALTA DE AIRE COMPRIMIDO COMMUNICAT...

Страница 17: ...l rules EN IEC 61131 2 2007 Programmable controllers Part 2 Equipment requirements and tests EN IEC 61000 6 2 2005 Electromagnetic compatibility EMC Part 6 2 Generic standards Immunity for industrial...

Страница 18: ...rolGo 17 ANNEX Fig I Dimensions Panel A C D E F B mm in A 435 17 1 B 400 15 7 C 400 15 7 D 425 16 7 E 225 8 9 F 210 8 3 Fig II SlaveBoards Fig III SlaveBoard PC board CAN OUT CAN IN Fig IV Connection...

Страница 19: ...ILTERSVERSTOPT FILTER GES TTIGT FILTRES OBSTRU S FILTROS OBSTRUIDOS NO COMPRESSED AIR GEEN PERSLUCHT KEINE DRUCKLUFT ABSENCE D AIR COMPRIM FALTA DE AIRE COMPRIMIDO COMMUNICATION ERROR COMMUNICATIEFOUT...

Страница 20: ...ssed air switch 9 Filter pressure sensor PT 2500 H05VV F 3G0 5 10 SCS Slave valve H05VV F 3G0 75 11 Fan control direct online H05VV F 4X0 5 12 Control cable SCS valve compressed air switch H05VV F 5G0...

Страница 21: ...l open B Push and hold the black button Turn the main switch on at the same time Continue to hold the button the white LED shows a heartbeat blinking pattern Learning Mode is starting up C When the gr...

Страница 22: ...5 seconds B Make sure that the number of flashes corresponds with the number of filter cartridges C If NOT and the buzzer sounds no filter cartridges are detected at all Push the black button during 5...

Страница 23: ...FAN SCS 2 SCS 2 ready A B Flowchart SCS 2 Explanatory notes A By default the yellow LED blinks one time with an interval of 5 seconds B Push the green button to change the setting from 1 to 2 filter s...

Страница 24: ...mware update has failed Possible causes failure during the update process corrupt update files on the USB stick you have tried to upload an older firmware version than the existing one you have tried...

Страница 25: ...www plymovent com 0000112607 010420 A ControlGo...