Plux biosignalsplux Temperature Скачать руководство пользователя страница 3

Temperature (TMP) 

User Manual  

 

 

  

 

 3 of 16 

 

 

TABLE OF CONTENTS

 

1.

 

General Information ............................................................................................................. 4

 

1.1. General Description ........................................................................................................... 4

 

1.2. Typical Unfiltered Sensor Output........................................................................................ 4

 

1.3. Sensor Specifications ......................................................................................................... 5

 

1.4. Features ............................................................................................................................ 5

 

1.5. Applications....................................................................................................................... 5

 

1.6. Transfer Function (Conversion Formula) ............................................................................. 5

 

1.7. Physical Characteristics ...................................................................................................... 6

 

2. Using the Temperature (TMP) Sensor with biosignalsplux & OpenSignals ................................... 7

 

2.1. Connecting the sensor to biosignalsplux Systems ................................................................ 7

 

2.1.1. biosignalsplux 4-Channel Hubs ............................................................................................. 7 
2.1.2. biosignalsplux 8-Channel Hubs ............................................................................................. 7 
2.1.3. biosignalsplux Solo & Single-Channel openBAN Devices ..................................................... 8 

2.2. Configuring the Sensor in OpenSignals................................................................................ 8

 

2.2.1. OpenSignals (r)evolution (Windows, macOS, Linux) ............................................................ 8 

3. Scientific Publications Using the Temperature Sensor .............................................................. 11

 

4. Safety & Maintenance ............................................................................................................ 12

 

4.1. Safety Instructions ........................................................................................................... 12

 

4.2. Transportation and Storage.............................................................................................. 13

 

4.3. Cleaning .......................................................................................................................... 13

 

5. Ordering Guides, Regulatory & Legal Information .................................................................... 14

 

5.1. Ordering Guide ................................................................................................................ 14

 

5.2. Guarantee of Quality & Warranty ..................................................................................... 14

 

5.3. Warranty Voidance .......................................................................................................... 14

 

5.4. Contact & Support ........................................................................................................... 14

 

5.5. Regulatory Disclaimer ...................................................................................................... 15

 

 

Содержание biosignalsplux Temperature

Страница 1: ...biosignal acquisition tool kit for advanced research applications Temperature TMP Sensor User Manual ...

Страница 2: ...d of the possibility of such damages ATTENTION Please read this datasheet before using your biosignalsplux sensor The information contained in this document has been carefully checked and were made every effort to ensure its quality PLUX reserves the right to make changes and improvements to this manual and products referenced at any time without notice The word Bluetooth and its logo are trademar...

Страница 3: ...lux Systems 7 2 1 1 biosignalsplux 4 Channel Hubs 7 2 1 2 biosignalsplux 8 Channel Hubs 7 2 1 3 biosignalsplux Solo Single Channel openBAN Devices 8 2 2 Configuring the Sensor in OpenSignals 8 2 2 1 OpenSignals r evolution Windows macOS Linux 8 3 Scientific Publications Using the Temperature Sensor 11 4 Safety Maintenance 12 4 1 Safety Instructions 12 4 2 Transportation and Storage 13 4 3 Cleaning...

Страница 4: ...n direct skin contact Additionally the small form factor of the sensor and small diameter of the sensing element 2mm enable possibilities of local and accurate temperature measurements within a 0 C and 50 C temperature range Figure 1 biosignalsplux TMP sensor 1 2 Typical Unfiltered Sensor Output Figure 2 shows a typical unfiltered TMP sensor output The raw digital sensor values received from the b...

Страница 5: ...ted into digital values ranged between 0 and 2n 1 n sampling resolution usually 8 bit or 16 bit and streamed in the raw digital format In most applications the original physical unit of the acquired TMP signal is preferred or required The raw digital sensor samples can be converted back into Celsius degrees ºC using the following formulas 𝑁𝑇𝐶 𝑉 𝐴𝐷𝐶 𝑉𝐶𝐶 2𝑛 1 𝑁𝑇𝐶 𝑚𝑉 𝑁𝑇𝐶 𝑉 1000 2 𝑁𝑇𝐶 𝛺 1 104 𝑁𝑇𝐶 𝑉 𝑉𝐶...

Страница 6: ...C should be considered as 𝐴𝐷𝐶 17361 𝑖𝑓 𝐴𝐷𝐶 17361 50161 𝑖𝑓 𝐴𝐷𝐶 50161 𝐴𝐷𝐶 𝑜𝑡ℎ𝑒𝑟𝑤𝑖𝑠𝑒 1 7 Physical Characteristics W1 x L1 x H 1 6cm x 2 2cm x 0 5cm W2 1 0 0 1cm W3 1 90 0 01mm L2 8 25mm 0 01mm A1 105 0 0 5cm A2 90 0 0 5cm S 0 3 0 1cm Available sleeve colors White Black Blue Green Red Yellow Gray and Brown Figure 3 Physical characteristics of the standard TMP sensor ...

Страница 7: ...mpatible with the reference ground port Connect the sensor to an analog input to use it with this device Figure 4 TMP compatible biosignalsplux channels green checkmarks 2 1 2 biosignalsplux 8 Channel Hubs The biosignalsplux TMP sensor is compatible with all 8 analog input channels of the 8 channel biosignalsplux hub but incompatible with the reference ground and digital I O ports Connect the sens...

Страница 8: ...el to use it with this device Figure 6 Connect the TMP to the analog input channel of the biosignalsplux Solo openBAN 2 2 Configuring the Sensor in OpenSignals 2 2 1 OpenSignals r evolution Windows macOS Linux Note Download OpenSignals r evolution here https biosignalsplux com index php software Open the OpenSignals r evolution device manager to access and configure your biosignalsplux device Figu...

Страница 9: ... sensor is connected to and select the TEMP from the dropdown menu highlighted in the next screenshot Figure 9 Set the channel type of the channel you have your TMP sensor connected to TEMP Activate the channel for acquisition by clicking on the circle next to the channel type must be blue If not done before follow the instruction available in section 2 1 Connecting the sensor to biosignalsplux Sy...

Страница 10: ...Temperature TMP User Manual 10 of 16 Figure 10 Start the acquisition whenever you re ready ...

Страница 11: ...ethodology for the accurate and prompt prediction of symptomatic events in chronic diseases in Journal of Biomedical Informatics no 62 pp 136 147 2016 J Heinisch I Hübener K David The Impact of Physical Activities on the Physiological Response to Emotions in Proc of the 2nd International Workshop on emotion awareness for pervasive computing with mobile and wearable devices pp 824 829 2018 A Kamenz...

Страница 12: ...s or other approved accessories purchased from PLUX or by a PLUX agent The user should inspect the sensors on a regular basis to ensure that they remain in good working order The user should stop using the biosignalsplux device if experience any kind of discomfort or skin irritation Do not use the system on persons with allergies to silver The user should dispose detection surfaces after using the...

Страница 13: ... C to 30 C Atmospheric pressure between 500hPa and 1060hPa Whenever the equipment needs to be transported it should be placed in the original box since this was designed and tested to ensure the equipment and accessories are securely stored Take care while handling the transportation of the system and avoid dropping it since the device is not shock proof and should not be placed under stress or su...

Страница 14: ...ty Voidance Usage of the device that is not in accordance with the handling instructions indicated in the manual or use with accessories other than those manufactured by PLUX will invalidate the warranty of your devices Be careful when connecting your biosignalsplux devices sensors and or accessories to any third party device including the usage of the 3rd party connection components that are avai...

Страница 15: ...nosis cure mitigation treatment or prevention of disease We expressly disclaim any liability whatsoever for any direct indirect consequential incidental or special damages including without limitation lost revenues lost profits losses resulting from business interruption or loss of data regardless of the form of action or legal theory under which the liability may be asserted even if advised of th...

Страница 16: ...il plux plux info web http www plux info Headquarters Zona Industrial das Corredouras Lt 14 1 2630 369 Arruda dos Vinhos Portugal tel 351 263 978 572 fax 351 263 978 902 Lisbon Office Av 5 de Outubro n 70 2 1050 059 Lisboa Portugal tel 351 211 956 542 fax 351 211 956 546 ...

Отзывы: