– 2 –
5. Connect Power
Connect an external AC power source to the PSUs.
6. Verify Switch Operation
Verify basic switch operation by checking the system LEDs.
When operating normally, the PSU1/PSU2, Diag, and Fan
LEDs should all be on green.
7.
Configuring the switch
To configure your switch please refer to the Pluribus Networks
Quick Start Guide available at this location:
http://www.pluribusnetworks.com/get-started/
8.
View the Product Label
The switch product label is located below SFP+ ports 7–12
on left side of the front panel. Pull the label out to view the
product information.
1
1
1
1
1
Hardware Specifications
Switch Chassis
Size (WxDxH)
438.4 x 473 x 43.4 mm (17.26 x 18.62 x 1.71 inches)
Weight
8.95 kg (19.73 lb), with two installed PSUs
Temperature
Operating: 0° C to 40° C (32° F to 104° F)
Storage: -40° C to 70° C (-40° F to 158° F)
Humidity
Operating: 5% to 95% (non-condensing)
Power
Consumption
282 Watts maximum
AC PSU
Power Rating
100–240 VAC, 50-60 Hz, 400 Watts
AC Input
100–240 VAC, 50-60 Hz, 6–3 A
DC Output
5 VDC @ 3 A, 12 VDC @ 33 A
Regulatory Compliances
Emissions
EN 55022:2010 +AC:2011, Class A
AS/NZS CISPR 22: 2009+A1: 2010, Class A
CISPR 22:2008, Class A
EN 61000-3-2:2006 +A1:2009+A2:2009, Class A
EN 61000-3-3:2013
FCC Class A
VCCI Class A
CE Mark
CCC GB 9254-2008
BSMI EMI Standard CNS 13438:2006
Immunity
EN 55024:2010
IEC 61000-4-2:2008 ED. 2.0
IEC 61000-4-3:2010 ED. 3.2
IEC 61000-4-4:2012 ED. 3.0
IEC 61000-4-5:2005 ED. 2.0
IEC 61000-4-6:2013 ED. 4.0
IEC 61000-4-8:2009 ED. 2.0
IEC 61000-4-11:2004 ED. 2.0
Safety
UL (CSA 22.2 No 60950-1 & UL60950-1)
CB (IEC/EN60950-1)
CCC GB4943.1-2011
BSMI Safety Standard CNS14336-1
Quick Start Guide