Functional Description and Specifications RUB VM
Page 21
System Set-up
reflects the current set-up as selected by a configuration tool:
set-up
‘
OK’
or ‘
failure’
. This is the result of the power-on check. In case of a failure all
settings have been reset to the default values automatically.
GPI alarm output
‘
low active
’ or ‘
high active
’.
maximum number of simultaneous changeover switching
1 … 6.
For each channel: channel 1 to 6 + spare:
changeover relay
‘
auto
’ or ‘
open
’ or ‘
close
’. Indicates the operating mode of each relay.
GPI alarm output
‘
enabled
’ or ‘
disabled
’.
SNMP traps
‘
enabled
’ or ‘
disabled
’.
System Status
shows all relevant status information:
input signal status
‘
OK’
/
‘
failure’
. This status corresponds to status of the spare output.
frequency
’10 MHz
’. Indicates the fixed nominal fre
quency of the signal input.
input signal received
’yes
’ or ‘
no
’. Monitoring and changeover procedure
start if at least
once a valid signal has been detected.
led OPER
‘
on
’/‘
off
’.
‘on’ if the module is operating.
led SIGNAL
‘
on
’/‘
off
’.
‘on’ if a valid in
put signal has been detected once.
led SET
‘
on
’/‘
off
’.
‘on’ during connection with “RUBIDIUM CONFIGURATION“.
led ERROR
‘
on
’/‘
off
’.
‘on’ if any error has been detected
(
total number of errors
> 0).
lamp 1
‘
on
’/‘
off
’.
‘on’ if any alarm has been set
(
total number of alarms
> 0).
lamp 2
‘
on
’/‘
off
’.
No function.
lamp 3
‘
on
’/‘
off
’.
‘on’ if input signal is present (IN) –
corresponds to the spare output.
lamp 4
‘
on
’/‘
off
’.
‘on’
if all the six output signals are present (OUT).
total number of errors
0
–
65 535. Current value of the overall error counter.
total number of alarms
0
–
65 535. Current value of the overall alarm counter.
number of activated changeover relays
0
–
6.
For each channel: Channel 1 to 6 + spare:
status
‘ok’ or ‘fail’. Indicates the curr
ent signal status.
changeover relay
‘
open
’ or ‘
closed
’.
Current state of the relay (channel 1 - 6).
GPI alarm output
‘
-
’ or ‘
set
’. Indicates the current state of the GPI al
arm.
errors
0
–
65 535. Current value of the individual error counter.
alarms
0
–
65 535. Current value of the individual alarm counter.
changeover events: Reports about the last changeover. Reset of these data by key FAIL or
RESET or button ERROR RESET of a configuration tool.
automatic
0
–
65 535. Counts the automatic changeover events since last RESET.
manual
0
–
65 535. Counts the manual changeover events since last RESET.
last event
Indicates the kind of the last event: automatic/manual
–
open/close.
time since last event
00000:00:00 [HHHHH:MM:SS]. Time elapsed since last changeover.