Plura RUB VI Скачать руководство пользователя страница 17

Functional Description and Specifications RUB VI 

Page 17 

 

System Failure

 

Check the “S

ystem Failur

e“ checkbox

 

Active, as long as the “

total number of alarms

” counter has a count value > 0

This trap feature becomes active in any event of those errors which simultaneously raise 

a GPI alarm, 

i.e. the “

disable

“ 

checkbox is not checked. This trap will be repeated in an 

8 hours interval as long as the alarm condition is present. 

Signal Failure 

Check the “Signal Failure“ checkbox

 

This trap indicates an error at one of the output stages (1 to 7). This trap includes the 

number of the output channel. Each channel  can have this trap feature disabled. This 

trap will be repeated in an 8 hours interval as long as the alarm condition is present. 

Error and Alarm Reset 

The following error indications are self resettable (reset, if no errors are present): 

 

The individual 

status bits at the status monitor

 

GPI outputs

 

The 

Signal Failure

 SNMP traps. 

 

The following error indications remain as long as the overall counters have count values > 0: 

total number of errors

“ > 0

 

total number of failures

“ > 0

 

 

LED with 

Error

 function. 

 

SNMP trap 

System Error

 

Lamp with 

Fail

 function. 

 

SNMP trap 

System Failure

A reset of these counters and 

 at the same time 

 a reset of all individual error counters can 

be done by: 

Keystroke

 

 

RUB1  modules,  i.e.  modules  plugged  to  a  H1,  D1,  Q1,  S1,  or  T1  chassis,  offer  four 

programmable keys. The following functions are provided for a reset: 

Function 

Description 

Recommended 

Key 

Counter Clear 

Resets all error counters to zero. 

F1: FAIL 

Reset 

Complete reset of error counters and status. 

F2: RESET 

Configuration

 

 

Utilizing one of the configuration tools, a complete reset of error counters and status can 

be done clicking the “

Error Reset“

 button at the 

Distribution

 page. 

Содержание RUB VI

Страница 1: ...Functional Description and Specifications Version 3 1 June 19 2020 RUB VI LTC or IRIG Time Code Distribution Amplifier Supplement to the Installation Systems Manual RUBIDIUM SERIES...

Страница 2: ......

Страница 3: ...ATE 10 2 OPERATING DESCRIPTION 11 2 1 FUNCTIONAL OVERVIEW 11 2 2 MONITORING AND STATUS INFORMATION 12 2 3 SIGNAL CHANGEOVER 14 2 4 ERRORS AND ALARMS 15 3 STATUS MONITOR 18 3 1 STATUS MONITOR BY THE IE...

Страница 4: ...hanical photocopying recording or otherwise without the prior written consent of Plura Europe GmbH Printed in Germany Technical changes are reserved All brand and product names mentioned herein are us...

Страница 5: ...l RUBIDIUM SERIES Please read the below listed chapters of the Installation Systems Manual RUBIDIUM SERIES as these chapters are necessary for the safe and proper use of the Rubidium module VI A3 Warr...

Страница 6: ...relay connected to the FAIL_A and FAIL_B pins of the RLC connector at the rear of the frame RS232 and TC_link RLC connector interfaces to have access to the internal bus of the chassis Four programma...

Страница 7: ...PI_4 2 GPI_1 3 GPI_5 6 GPI_2 4 GPI_6 5 GPI_3 7 GPI_7 OUTPUT DSUB25F female 1 GND 3 GND 5 GND 7 GND 9 GND 11 GND 2 OUT1_A 4 OUT2_A 6 OUT3_A 8 OUT4_A 10 OUT5_A 12 OUT6_A 14 OUT1_B 16 OUT2_B 18 OUT3_B 20...

Страница 8: ...lector output of an NPN Darlington transistor Max power dissipation 200 mW High state external pull up needed to a positive power source of less than or equal to 30 VDC typically 1 k when connected to...

Страница 9: ...INPUT VI VI LTC PrimaryCircuit 1 5 2 Example of a Redundant IRIG B Distribution System 18 Outputs 1 RLC PC 1 RLC PC PS PS PrimaryCircuit2 PrimaryCircuit1 1 GPI B GPI A REF IN IRIG IRIG 8 1 8 1 8 1 8 1...

Страница 10: ...ht 1 1 connection between the PC connector at the RUBIDIUM frame and the RS232 of the computer In case of an USB interface Use a USB A B cable between your computer and the RUBIDIUM frame Switch on th...

Страница 11: ...hangeover Changeover Changeover The monitoring part outputs the following status Input signal status Time decoded out of the input signal Status of each output channel State of all changeover relays E...

Страница 12: ...le time data An error detected at the spare output could be considered as an error of the signal input There is a changeover relay at each of the six outputs If an error is detected at an output stage...

Страница 13: ...signal at all or LTC with incorrect time addresses Spare output stage Signal failure for one second or more Channel 1 to channel 6 output stages Signal failure for two seconds or more fail of IRIG B N...

Страница 14: ...put signal status OK time out data error input signal received yes no An error at the spare output stage will not affect the changeover relays The changeover relay will open its contacts if no error c...

Страница 15: ...an LED or lamp at the module and or by an SNMP trap Errors Any error detected on a signal always leads to the following error indications At the status monitor The total number of errors counter show...

Страница 16: ...f the RUB IE module with option S SNMP Utilizing one of the configuration tools SNMP traps can be enabled and disabled at the System page please refer to chapter System Identification Reset SNMP Fan C...

Страница 17: ...ations are self resettable reset if no errors are present The individual status bits at the status monitor GPI outputs The Signal Failure SNMP traps The following error indications remain as long as t...

Страница 18: ...and how to open the RUBIDIUM homepage At the RUBIDIUM homepage click on Configuration to open the Configuration page Click on VI on the left Click on the button Status Monitor to open the VI status mo...

Страница 19: ...ad at https www plurainc com Execute this program select the COM port or USB connection and press the scan button to get a list of the modules plugged to this housing Select the module and press the c...

Страница 20: ...20 3 3 System Status This module monitors the signals at the seven output stages with respect to frequency minimum amplitude and plausible time data The status monitor informs about the state of each...

Страница 21: ...total number of errors 0 lamp 1 on off on if any alarm has been set total number of alarms 0 lamp 2 on off No function lamp 3 on off on if input signal is present IN corresponds to the spare output l...

Страница 22: ...s of Fan and Power Supplies This module as all configurable RUBIDIUM modules is able to monitor the fan and power supplies which are plugged to the same housing as VI Please refer to the document Inst...

Страница 23: ...Overview Installation Connection to RUBIDIUM SERIES Chassis Starting the Program Store Load and Update the Configuration on your PC The Profile Tab Store and Load Configurations on the Module The prog...

Страница 24: ...ERIES Module The Profile Page Store and Load Configurations on the Module or on the PC As soon as a communication to a single module has been established the Configuration page gives a list of all lin...

Страница 25: ...Edit Use Function is deactivated the tab page is not visible Function is activated the tab page is visible and configurable Function is activated but the tab page not visible and therefore not config...

Страница 26: ...asically the functions of these in and outputs are programmable Some functions presented by the configuration tool maybe assigned to special options and therefore are not applicable with the standard...

Страница 27: ...alarm has been set total number of alarms 0 Reset by key FAIL or RESET or button ERROR RESET of a configuration tool F1 FAIL Lamp IN Lights up if an input signal is present or spare output signal is p...

Страница 28: ...at seven output stages Six signal outputs one spare output There are changeover relays at each of the six outputs If a signal output fails a changeover to the spare output via relay can be done The D...

Страница 29: ...lue 1 to 6 Select this parameter according to your application Channels Each output stage except the spare output has a changeover relay The operating mode of each relay can be selected individually A...

Страница 30: ...module If you select Auto the module will request this frame number automatically and will show it on the info box Likewise it is possible to select a frame number manually Boot Cold Boot Do a cold b...

Страница 31: ......

Страница 32: ...U S A Germany U A E S Korea www plurainc com...

Отзывы: