Plum eSTER x80 Скачать руководство пользователя страница 14

14 

 

Connection  with  ecoMAX800P1,  P2,  D1, 
D2 and ecoMAXX800R2, T2:  
All  1,2,3  room  panels  require  application  of 
an  additional  power  adapter  12  VDC  /  min. 
0.5 A. 

 

Connection with ecoMAX800 P3, D3 and 
ecoMAXX800 R3, T3: 

 

Controller module can supply up to 
2  colored  TOUCH  type  panels 
simultaneously.

 

If  the  main  controller  is  equipped  with  a 
standard control panel (version with a knob), 
two  room  panels  can  be  supplied  directly 
from  the  controller  module  (terminal  31). 
Third  panel  has  to  be  supplied  by  the 
additional  power  adapter  12  VDC  /  min.  0.5 
A. 

 

If  the  main  controller  is  equipped  with  TOU 
CH  control  panel  (colored  with  a  touch 

panel), only one room panel can be supplied 
directly from the controller module (terminal 
31).  Panels  2  and  3  have  to  be  supplied  by 
the  additional  power  adapter  12  VDC  /  min. 
0.5 A. 

 

Connection with ecoMAX850P1, R1, D1: 
All  1,2,3  room  panels  require  application  of 
an  additional  power  adapter  12  VDC  /  min. 
0.5 A. 

 

Connection with ecoMAX850P2, R2, D2: 

 

Controller module can supply up to 
2  colored  TOUCH  type  panels 
simultaneously. 

If  the  main  controller  is  equipped  with  a 
standard control panel (version with a knob), 
two  room  panels  can  be  supplied  directly 
from  the  controller  module  (terminal  40). 
Third  panel  has  to  be  supplied  by  the 
additional  power  adapter  12  VDC  /  min.  0.5 
A. 

Содержание eSTER x80

Страница 1: ...ISSUE 1 1_EN WIRELESS ROOM PANEL eSTER_x80 FOR HEATING CIRCUIT CONTROLLERS 06 2019 ISM_xSMART the ISM_xSMART radio module is standard equipment for the wireless room panel ONLY COOPERATES WITH ecoMAX...

Страница 2: ......

Страница 3: ...NTROLLER ALARMS 7 8 11 SETTINGS 8 8 11 1 Hysteresis 8 8 11 2 Temperature correction 8 8 11 3 Screen brightness 8 8 11 4 Changing the language 8 8 11 5 PARENTAL LOCK 8 8 11 6 SOFTWARE UPDATE 8 8 11 7 S...

Страница 4: ...ly industrialized buildings 3 Applied symbols In this manual the following graphic symbols are used the symbol indicates additional advice and information the symbol indicates important information Ca...

Страница 5: ...sition from the menu The symbols mean w selection of the main Menu decrease increase the value of the selected parameter scroll the parameters list up down exit a chosen Menu position or cancel a para...

Страница 6: ...ode in which it has been operating before the Out of home mode was set The symbol is displayed on the panel screen 8 3 5 Airing Selection of this mode will result in closing the mixing valves and swit...

Страница 7: ...time period set the indicator 2 to a starting hour of time zone with the use of buttons set the comfort day or economic night temperature with the use of button set the indicator 2 to an ending hour o...

Страница 8: ...8 11 6 Software update Enables updating the software with the use of a microSDHC memory card inserted into a slot in the panel enclosure in all connected devices controller additional modules control...

Страница 9: ...iring function with the radio module for 4 minutes The correct pairing will be confirmed by a message on the screen of the wireless room panel 8 11 13 Information The Information menu displays the str...

Страница 10: ...main controller socket using a 2 wire cable which should be connected in accordance with point 12 omitting the connection of the D and D signals To connect the room panel power supply you can use a 2...

Страница 11: ...he pairing mode will be activated for 4 minutes during this time the room panel with the radio module should be paired in accordance with point 8 11 12 During the active pairing mode you can pair in t...

Страница 12: ...els is possible only when the radio module program is fully compatible with the main controller To check if the main controller program is fully compatible with the radio module select the tab in the...

Страница 13: ...adio module 2 main controller Connection of the module to the ecoMAX860P1 P2 D1 D2 1 radio module 2 main controller Connection of the module to the ecoMAX860P3 D3 1 radio module 2 main controller Conn...

Страница 14: ...e main controller is equipped with TOU CH control panel colored with a touch panel only one room panel can be supplied directly from the controller module terminal 31 Panels 2 and 3 have to be supplie...

Страница 15: ...TOUCH type panels simultaneously If the main controller is equipped with a standard control panel version with a knob two room panels can be supplied directly from the controller module terminal 46 T...

Страница 16: ...equipped with TOUCH control panel colored with a touch panel only one room panel can be supplied directly from the controller module socket G4 Panels 2 and 3 have to be supplied by the additional pow...

Страница 17: ...e supplied by the additional power adapter 12 VDC min 0 5 A Connection with ecoMAX910R1 ecoMAX920P1 If the main controller is equipped with a standard control panel version with a knob or TOUCH contro...

Страница 18: ...5 868 MHz Transmission power of the wireless room panel and radio module 20 mW 13 dBm Radio network topology One radio module and many subordinate room panels Display Graphic 480 x 272 pix with touch...

Страница 19: ......

Страница 20: ...ul Wsp lna 19 Ignatki 16 001 Kleosin Poland plum plum pl www plum pl...

Отзывы: