Plum eSTER x40 Скачать руководство пользователя страница 15

15 

 

software  of  the  main  controller  so  that  this 
cooperation will be ensured. 

 

The  radio  module  can  operate  with 
up to three thermostats. 

  

 

Correctly  paired  thermostats  with  a 
radio  module  require  setting  an 
individual  address  for  each  of  the 
thermostats. 

The  address  for  the  thermostat  is  set  in  the 
user menu, parameter (

P35

). One should set 

a different address for each thermostat in the 
range 1..3. 
The  correctness  of  the  individual  address 
settings  can  be  checked  in  the  main 
controller 

Information

  menu,  where  the 

individual  thermostats  will  be  displayed  as: 
eSTER_x40  T1,  eSTER_x40  T2,  eSTER_x40 
T3.  
The  structural  elements  of  the  building,  the 
layout and equipment of rooms, the amount 
of  electronic  equipment,  the  distance 
between  the  installation  place  of  the  radio 
module and the thermostat affect the level of 
the  received  radio  signal,  therefore  when 
choosing  a  place  to  install  the  thermostat, 
take into account the obtained signal level in 
the  selected  location  by  observing  the 

symbol 

  on  thermostat  screen.  If  the 

symbol: 
-  is  not  displayed,  the  radio  connection  with 
the  radio  module  is  correct.  The  symbol  is 
shown  only  briefly  during  active  radio 
communication with the radio module,  

-  flashing,  there  is  no  radio  connection  or 
there is a weak signal and you should choose 
a different place to install the thermostat. 
The value of the radio signal strength can be 
read  in  parameter  (

P30

)  of  the  thermostat 

user menu. 

 

If  the  radio  connection  to  the 
thermostat  is  lost,  the  main 
controller  will  go  into  operating 
mode  without  a  thermostat  after  a 
few minutes. 

15.5

 

Connecting the radio module to 

selected main controllers 

The electrical schemes of the radio module's 
electrical connections to the main controller's 
terminals are shown below. 

 

Connection of the module to the 

ecoMAX350P1, 

P2,  R1,  R2

:  1 

  radio  module,  2 

  main 

controller.

 

 

Connection of the module to the 

ecoMAX800P3, 

D3

 and

 ecoMAXX800R3, T3

: 1 - radio module, 2 

 control panel, 3 

 main controller. 

Содержание eSTER x40

Страница 1: ...L ISSUE 1 0 WIRELESS ROOM THERMOSTAT eSTER_x40 FOR HEATING CIRCUIT CONTROLLERS 04 2019 ISM_xSMART The ISM_xSMART radio module is standard equipment for the thermostat ONLY COOPERATES WITH THE ecoMAX S...

Страница 2: ......

Страница 3: ...10 12 SIGNALING OF THE ALARMS AND PROMPTS 10 12 1 ALARMS 10 12 2 PROMPTS 10 13 SETTINGS OF THE MAIN CONTROLLER PARAMETERS 10 14 INSTALLATION OF THE THERMOSTAT 11 14 1 INSERTING OR REPLACING THE BATTE...

Страница 4: ...k synchronization with the main controller Radio communication 1 eSTER_x40 thermostat 2 ISM_xSMART radio module 3 main controller 3 Information about documentation The thermostat manual is a supplemen...

Страница 5: ...the main controller automatically sets the clock in the thermostat The clock can also be set directly in the thermostat from the User menu P04 The change of time in the thermostat will also cause a c...

Страница 6: ...ental lock unblocking occurs after holding the button for 5 seconds 10 Thermostat settings 9 1 Edition of the preset temperature Pressing or brings to the check edit of the preset temperature which st...

Страница 7: ...Antifreeze the thermostat works with a constant preset temperature Antifreeze P07 which ensures protection against freezing of water in the heating circuit This mode is useful when there is no one in...

Страница 8: ...ch means the interval 00 30 01 00 Use or buttons to move between intervals 48 intervals every 0 5 h For each interval the preset temperature Night or Day can be set The button assigns the night or day...

Страница 9: ...duration of the Airing mode min P14 Time one time of the HUW charging h P15 Turning on on or off oFF sound of pressing the buttons P16 Turning on on or off oFF sound alarms At the oFF setting alarm n...

Страница 10: ...er and the beep if P16 parameter is set to on The first press of the button silences the alarm sound With and buttons you can check successive alarm numbers if there are more of them at the same time...

Страница 11: ...e as a free standing device in a room representative for a given heating circuit After choosing the place of assembly make sure that the selected location is free of excessive humidity and the ambient...

Страница 12: ...nd connection of the radio module to the main controller The ISM_xSMART radio module should be mounted on a wall near the installation location of the main controller If the radio connection is poor t...

Страница 13: ...controller requires pairing with a thermostat Until the pairing with the radio module on the thermostat screen is complete the and symbols are permanently displayed Pairing from the main controller me...

Страница 14: ...adio connection with the thermostat in the main controller Information menu the thermostat will be visible as ecoSTER TOUCH with the given version of the software The pairing method with the P button...

Страница 15: ...o install the thermostat take into account the obtained signal level in the selected location by observing the symbol on thermostat screen If the symbol is not displayed the radio connection with the...

Страница 16: ...the module to the ecoMAX860P3 D3 1 radio module 2 main controller Connection of the module to the ecoMAX910R1 ecoMAX920P1 1 radio module 2 main controller It is not recommended to turn off the power s...

Страница 17: ...conditions i e rain and sun rays and vibrations higher than typical during road transport Storage and transport temperature should not exceed 10 60 C 18 Description of possible faults Symptoms Tips Th...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...ul Wsp lna 19 Ignatki 16 001 Kleosin Poland plum plum pl www plum pl...

Отзывы: