15
software of the main controller so that this
cooperation will be ensured.
The radio module can operate with
up to three thermostats.
Correctly paired thermostats with a
radio module require setting an
individual address for each of the
thermostats.
The address for the thermostat is set in the
user menu, parameter (
P35
). One should set
a different address for each thermostat in the
range 1..3.
The correctness of the individual address
settings can be checked in the main
controller
Information
menu, where the
individual thermostats will be displayed as:
eSTER_x40 T1, eSTER_x40 T2, eSTER_x40
T3.
The structural elements of the building, the
layout and equipment of rooms, the amount
of electronic equipment, the distance
between the installation place of the radio
module and the thermostat affect the level of
the received radio signal, therefore when
choosing a place to install the thermostat,
take into account the obtained signal level in
the selected location by observing the
symbol
on thermostat screen. If the
symbol:
- is not displayed, the radio connection with
the radio module is correct. The symbol is
shown only briefly during active radio
communication with the radio module,
- flashing, there is no radio connection or
there is a weak signal and you should choose
a different place to install the thermostat.
The value of the radio signal strength can be
read in parameter (
P30
) of the thermostat
user menu.
If the radio connection to the
thermostat is lost, the main
controller will go into operating
mode without a thermostat after a
few minutes.
15.5
Connecting the radio module to
selected main controllers
The electrical schemes of the radio module's
electrical connections to the main controller's
terminals are shown below.
Connection of the module to the
ecoMAX350P1,
P2, R1, R2
: 1
–
radio module, 2
–
main
controller.
Connection of the module to the
ecoMAX800P3,
D3
and
ecoMAXX800R3, T3
: 1 - radio module, 2
–
control panel, 3
–
main controller.