Podiatry Chair User Manual 

3 | 

P a g e

 

 

1.

 

Introduction 

 
Thank you for purchasing a product from Plinth Medical Ltd. We use the highest 
quality components and manufacturing techniques to ensure that our products are 
simple to use and will last a long time. It is recommended that all users read and 
retain this User Manual for reference. 
 
Throughout this manual notice is made of a Warning and Caution system to highlight 
to the user practices, procedures or conditions that should either not be allowed to 
happen or happen with caution. 
 

Warnings are in a box with bold type and identify potential hazards, procedures or 
conditions which could result in death, injury or serious damage

 

Cautions are in a box with plain type and identify conditions or procedures where if 
caution is not taken it may result in damage or failure of equipment. 

 

 
General Warnings 
 

WARNING 

 

Maximum Load (SWL) is 250kg distributed evenly. 

 

Do not use flammable gasses in proximity to an electrically operated chair. 

 

Do not concentrate weight on either side or either end of the chair. 

 

Use only accessories approved for use with this chair. 

 

Disconnect power supply before moving chair. 

 

Children must be adequately supervised in the presence of the chair. 

 

Do not allow children to play with the chair at any time. 

 
 

Содержание 503C

Страница 1: ...Podiatry Chair Models 503C 503CD 503CT 503CDT USER MANUAL...

Страница 2: ...Foot Section 7 Castor Operation 8 Armrest Operation 8 4 Accessories Operation 9 Paper Roll Holder 9 Battery Backup 9 Fold Down Cot Sides 10 Footswitch 10 5 Cleaning and Decontamination 11 6 Troublesh...

Страница 3: ...ings are in a box with bold type and identify potential hazards procedures or conditions which could result in death injury or serious damage Cautions are in a box with plain type and identify conditi...

Страница 4: ...he chair is used and whilst patients get on or off the chair Care should be taken to ensure patients do not trip over any part of the chair when getting off Adjustable Foot Fitted to the head end of t...

Страница 5: ...le CAUTION When chair is not in use switch off power supply Lifting and Moving Should the chair need to be moved or lifted for example to remove it from its packaging then a minimum of two people are...

Страница 6: ...ition the switch in a place where it is clear of the moving parts of the chair and where accidental operation is not possible Ensure that all electrical cables are clear of the moving parts of the cha...

Страница 7: ...whilst adjusting and release the lever to lock in the desired position Manual Leg Sections For versions that do not have a motorised leg sections The operation is via a gas spring mechanism triggered...

Страница 8: ...st be retracted before the chair is used and whilst patients get on or off Disconnect and coil electrical leads and switch away from the chair mechanism prior to moving the chair Armrest Operation The...

Страница 9: ...fitting the tube over the bar Re fit in the reverse order Battery Backup Battery backup is a useful option in case of power shortages It allows at least one full cycle under battery power to enable t...

Страница 10: ...lift up in the plastic block and then rotate a full 180 into the down position WARNING Ensure that the cot side is fully engaged in the plastic block whilst in use Footswitch An optional fitment foot...

Страница 11: ...e mains supply to the chair and move it to a suitable cleaning area and lock the castors Step 1 Using warm water and soap on a damp cloth carefully wipe the chair over from top to bottom Take great ca...

Страница 12: ...motor One motor will not work but others working 503CT 503CDT Lead from height motor control box not connected to slave motor Fault with switch Fault with control box Fault with motor Check and connec...

Страница 13: ...y are present and tight but not over tight Upholstery bolts should all be checked each section has between 2 and 6 No M6 bolts they should all be present and tight Check gas struts if fitted and ensur...

Страница 14: ...can offer both extended warranties and service contracts For further information about either of these please contact Customer Service Plinth Medical Barric Lane Occold Eye Suffolk IP23 7PX Tel 01449...

Страница 15: ...Data 220 240v Motor s Linak LA31 x 1 Linak LA31 x 1 Linak LA31 x 2 Linak LA31 x 2 Control Box Linak CB09 Linak CB09 Linak CB09 Linak CB09 Current 1 5A 1 5A 1 5A 1 5A Power 360W 360W 360W 360W Mains P...

Страница 16: ...me Date All Manual 01 Niall Dyer 13 06 2017 Plinth Medical Barric Lane Occold Eye Suffolk IP23 7PX ENGLAND Plinth Medical Ltd In association with Plinth 2000 are an ISO Audited company to ISO9001 2008...

Отзывы: