background image

MDR5800 User Manual

862-01881 Issue 6

Page 41

5.7

 

MDR5800 Test Record

Parameter

Unit

Site A

Site B

Frequency channel plan:

Transmit

Receive

A/B/C/D

A/B/C/D

If D – List
Transmit and
Receive
Frequencies
[MHz]

Transmitter output power

dBm

Receiver input level (ON)

Volts

Receiver input level (ON)

dBm

Receiver input level (OFF)

Volts

Receiver input level (OFF)

dBm

Calculated input level

dBm

Fade margin

dB

Frame Lock indicator

Colour

Fixed attenuator

dB

BER-test

Hours

BER

Alarm Indicators

Clear
(Yes/No)

Date

Name

Signature

Performed by

Approved by

Содержание MDR5800

Страница 1: ...MDR5800 User Manual 862 01881 Issue 6 Page 1 MDR5800 Digital Radio User Manual Document Number 862 01881...

Страница 2: ...is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful i...

Страница 3: ...Tellumat Pty Limited and is supplied without liability for errors or omissions No part may be reproduced used or disclosed except as authorised by contract or other written permission The copyright a...

Страница 4: ...16 2 3 3 Element Manager Port 16 2 3 4 10BaseT Ethernet RJ45 Port 16 2 3 5 IU OU Link LED 17 2 3 6 IU OU Data Interconnect RJ45 17 2 3 7 IU OU Power Interconnect 17 2 3 8 Auxiliary In Out Port 17 2 3...

Страница 5: ...Manager Port 31 4 3 Outdoor Unit 32 4 3 1 MDR5800 Outdoor Unit 32 4 4 Interconnection Cable Installation 33 4 4 1 INTERCONNECTION CABLE WIRING DESCRIPTION 34 5 ANTENNA ALIGNMENT AND SOFTWARE SETUP 36...

Страница 6: ...k Status 58 6 7 2 Packet Error Rate Thresholds 58 6 7 3 RF Link Error Monitor 59 7 MAINTENANCE INFORMATION 62 8 TECHNICAL DATA 64 8 1 Environmental Requirements 64 8 1 1 Outdoor Equipment 64 8 1 2 Ind...

Страница 7: ...Modem Windows 95 98 82 9 4 Adding Dial up Networking Windows 95 98 85 10 APPENDIX B MANAGEMENT OF THE MDR5800 87 10 1 SNMP and the MDR5800 87 10 2 The MIB Elements OID Object ID DESCRIPTIONS 89 10 3...

Страница 8: ...Digital Radio Link DRS Digital Radio Station DTE Data Terminal Equipment IU Indoor Unit ISM Industrial Scientific and Medical LED Light Emitting Diode LOS Loss of signal Mbps Megabits per second N C N...

Страница 9: ...rivate carriers Cellular PCS base station interconnects Internet distribution Video surveillance data distribution Rural communications The MDR5800 consists of two main parts An Outdoor Unit operating...

Страница 10: ...2 x E1 2 x T1 10BaseT Ethernet N type Female Customer supplied MDR5800 ET4 4 x E1 4 x T1 10BaseT Ethernet N type Female Customer supplied Refer to section 8 for Ordering details The Network Management...

Страница 11: ...Indoor Unit also provides power to the Outdoor Unit Interconnection between Outdoor Unit and Indoor Unit is achieved using low cost data and power cables 2 2 Outdoor Unit The MDR5800 Outdoor Unit mak...

Страница 12: ...nel spacing for frequency channel plans A B and C is 69 MHz The channel spacing is based on the bandwidth occupied by the spread spectrum signal approximately 17 MHz and is used to optimise link perfo...

Страница 13: ...allocation of Channel plan D frequencies is shown in Table 2 Table 2 Channel plan D channel frequencies Sub band Center Frequency MHz L 5735 5771 H 5804 5840 2 2 2 RF Power Output Options The Outdoor...

Страница 14: ...x E1 2 048 Mbps 1 2 or 4 x E1 1 544 Mbps For E1 connectivity bipolar AMI or HDB3 line coding is software selectable For T1 connectivity bipolar AMI or B8ZS line coding is software selectable Figure 2...

Страница 15: ...r a ROUTED IP configuration set the Ethernet IP address as 10 11 1 2 Element Manager IP address to 10 12 1 2 5 Routed Configuration Reset the IU configuration parameters that are stored in non volatil...

Страница 16: ...LANK THEN START AGAIN OPTION AVAILABLE WITH RELEASE 2 OF IU FIRMWARE 2 3 2 Service Wayside Serial Data Channel This port supports asynchronous full duplex serial data transfer at a speed of 115200 bps...

Страница 17: ...tained between the IU and the OU 2 3 8 Auxiliary In Out Port The auxiliary in out port is used for remote monitoring and control The following are provided Two inputs for sensing contact closure or op...

Страница 18: ...g 2 core cable The cable is connected to a GREY connector a plug The polarity sense labelled must be observed and implemented 2 3 10 Fuse Holder This holder is used to hold a fuse 5A 2 3 11 ON OFF Swi...

Страница 19: ...MDR5800 User Manual 862 01881 Issue 6 Page 19 This page is left blank intentionally...

Страница 20: ...The antenna type must be selected before the MDR5800 system is to be installed The chosen antenna must enable the system to operate with sufficient link fade margin without excessive cost and allow th...

Страница 21: ...ibration of the mast mounted equipment 3 3 Multipath Effects The MDR5800 digital radio operates at frequencies close to 5 8 GHz and can be influenced by the effects of multipath propagation Understand...

Страница 22: ...han 20 dB below the intended receive power level A link path loss calculation should be performed to determine the expected receive power level The procedure for selecting the optimum antenna polarisa...

Страница 23: ...ne that it uses for transmission and another for reception Terminology definition the High band Outdoor Unit of a system transmits on the higher of the two sub bands The Low band Outdoor Unit of a sys...

Страница 24: ...MDR5800 User Manual 862 01881 Issue 6 Page 24 This page is left blank intentionally...

Страница 25: ...cables 5 Turn the Indoor Unit power on 6 Perform the initial software setup using the supplied NMS application 7 Repeat item 1 5 for the remote site 8 Align the antennas use the RSSI voltage on the OU...

Страница 26: ...er IU mounting in a 19 rack and the earth lug 2 5mm Allen key To change the position of the IU mounting brackets DC power supply cable minimum 2 5 mm square conductor rated for 10 A For connection bet...

Страница 27: ...installations The recommended installation procedure for the Indoor Unit is the following Install the Indoor Unit in the rack Earth the Indoor Unit Connect the DC power supply Connect Payload data po...

Страница 28: ...polarity of the supply wire up the supplied power connector cable plug and connect it to the DC supply 21 to 56 V through a minimum 5 A circuit breaker 2 Check the supply voltage using a multimeter 3...

Страница 29: ...panel of the Indoor Unit D Type Payload Data Connector Pin Pin Name Tributary Direction 1 GND Earth N A 2 RTIP1 1 RX 3 RRING1 1 RX 4 GND Earth N A 5 TTIP1 1 TX 6 TRING1 1 TX 7 GND Earth N A 8 GND Eart...

Страница 30: ...tor pin assignments shown in Table 4 2 Connect to the cable Indoor Unit auxiliary in out connector 3 Secure the connector using locking screws Table 4 Auxiliary In Out Connector Pin Outs Indoor unit c...

Страница 31: ...re setup is completed 2 See the table below for Indoor Unit connector pin assignments when a custom cable needs to be assembled 3 Secure the connector using locking screws Service Channel Connector Pi...

Страница 32: ...to the pole electrically by connecting the earth cable or strap between the pole earth and the Outdoor Unit earth point 6 Connect the type N RF output connector to the system antenna through an in li...

Страница 33: ...over using a 2 5mm Allen key Make sure the rubber gaskets seal correctly over the power and data cables 4 Using cable ties secure the cable to the pole at regular intervals 5 On the IU side connect an...

Страница 34: ...SCRIPTION 1 8 TOP VIEW LOCKING TAB UNDERNEATH RJ 45 PLUG Pin DTE on INDOOR UNIT DCE on OUTDOOR UNIT Wiring 1 TxD RxD Orange White 2 TxD RxD White Orange 3 RxD TxD Green White 4 TxC RxC Blue White 5 Tx...

Страница 35: ...881 Issue 6 Page 35 NOTE VERSION 1 AND 2 RELEASES OF THE HARDWARE INDOOR AND OUTDOOR UNITS CANNOT BE USED INTERCHANGEABLY FOR VERSION 2 IU OU HARDWARE USE OF TxC TxC RxC RxC FALLS AWAY AND ONLY TWO 2...

Страница 36: ...end site This will assist in the antenna alignment operation GPS or Standard Compass optional used for locating the far end site This will assist in the antenna alignment operation Bit Error Rate Test...

Страница 37: ...e using the pathloss calculation done when planning the link Figure 5 RSSI as a function of RF input level The front panel RF Link LED the Received Signal Strength Indicators RSSI on NMS via SNMP or a...

Страница 38: ...on both sides of the RF link should be GREEN When the link has been setup and is running error free 1 Clear the Indoor Unit Log using Reset Button Position 2 2 Clear the Indoor Unit Errors using Reset...

Страница 39: ...MDR5800 User Manual 862 01881 Issue 6 Page 39 Record all results on a test record See MDR5800 Test Record section 5 7 for an example...

Страница 40: ...Site B Site Name Antenna Type RF cable length Meters Lightening protection unit Yes No Interconnecting cable length Meters Outdoor Unit serial number Indoor Unit serial number Outdoor Unit earthed Yes...

Страница 41: ...ransmit and Receive Frequencies MHz Transmitter output power dBm Receiver input level ON Volts Receiver input level ON dBm Receiver input level OFF Volts Receiver input level OFF dBm Calculated input...

Страница 42: ...MDR5800 User Manual 862 01881 Issue 6 Page 42 This page is left blank intentionally...

Страница 43: ...r system installation and commissioning It connects to a designated NMS Terminal port labelled Element Manager on the front panel of the Indoor Unit of a MDR Station installation by means of a serial...

Страница 44: ...acility or you can use the Find facility to search for key words connected to the specific information required 6 2 1 Microwave Digital Radio A MDR link consists of at least one complementary pair of...

Страница 45: ...and unavailable The Main screen shows a local station on the left hand side of the screen and a remote station on the right hand side of the screen The Main Menu area provides pull down menus and con...

Страница 46: ...tatus bar at the bottom of the screen shows that the stations are being polled If there is no communication with the remote side the remote station will be greyed If there is no communication with the...

Страница 47: ...ings for the local station equipment to allow the user to log on as an Administrator with full read write configuration access or with Read only access Note This option is only available if the IU fir...

Страница 48: ...e the serial port as follows 1 Select Communications from the menu on the main screen 2 Select the required port COM1 COM2 COM3 or COM4 6 4 1 2 2 Polling Cycle Set the polling cycle minimum 3 seconds...

Страница 49: ...Service Channel Port Loopback to Line and loopback to RF Link Opto Inputs Relays Payload is from the user s line equipment to the Indoor Unit Payload Data DB25 connector and RF Link is from Antenna to...

Страница 50: ...nnel Port The service channel serial port provides a means to send asynchronous data across the link to the far side service channel port Service channel ports can be connected back to back i e Remote...

Страница 51: ...Use the Exit button to exit without any changes being made 6 5 1 5 Indoor Unit Loopback Controls These controls allow you to set the loopbacks on the payload data IU Loopback to Line Used to loopback...

Страница 52: ...oor Unit Not Responding The Outdoor Unit simply doesn t respond to any messages sent to it by the Indoor Unit The Outdoor Unit could possibly be damaged or the cables to the Outdoor Unit are disconnec...

Страница 53: ...n Flash device will have to be replaced DRAM Error The DRAM test failed Only a faulty DRAM device can cause this fault and the DRAM will have to be replaced SRAM Error The battery backed up SRAM test...

Страница 54: ...ndoor Unit at time of manufacture 6 5 2 6 Indoor Unit Event Log This screen is used for the viewing of the event log file In the event of a persistent field fault it will be useful for you to save the...

Страница 55: ...ss As the upload process proceeds the user is informed of progress Verification of upload is done once the file has been uploaded into DRAM Thereafter the data is loaded into Application Flash The lat...

Страница 56: ...ice of arrows on the OU being tested 2 Select the Loopback Timeout Time in seconds If enabled the Loopback state will cancel after Time seconds and the unit will return to normal operation 3 Click on...

Страница 57: ...wo Indoor Units has not reactivated within 5 seconds the previous working default RF parameters are programmed into the respective Outdoor Units 6 6 3 OU Station Info The OU Station Info screen provid...

Страница 58: ...ded due to Packet errors on the RF link BBER Exceeded RF Background Block Packet Errors Ratio has been exceeded due to block errors on the RF link Default RF Parameters Activated The Operational RF pa...

Страница 59: ...eport Time 6 7 2 2 Link Availability A period of unavailable time begins at the onset of ten consecutive SES events These ten seconds are considered to be part of unavailable time A new period of avai...

Страница 60: ...of the number of Background Blocks in errors to the total number of blocks received since the counters were last reset Corrected Symbols field shows the number of symbols that have been corrected by t...

Страница 61: ...MDR5800 User Manual 862 01881 Issue 6 Page 61 This page is left blank intentionally...

Страница 62: ...3 Section 4 of this manual lists customer furnished equipment that should be used for installing the MDR product 4 There are two options to control the MDR5800 product via SNMP a One uses any open sta...

Страница 63: ...MDR5800 User Manual 862 01881 Issue 6 Page 63 This page is left blank intentionally...

Страница 64: ...ive humidity 5 90 Lightning protection ITU T K 20 8 2 Mechanical Information for Outdoor Equipment 8 2 1 MDR5800 Outdoor Unit Dimensions HxWxD 335mm x 231mm x 124mm Weight 5 9 Kg 8 3 Mechanical Inform...

Страница 65: ...SM licence free bands Modulation CCK Processing Gain 11 dB Frequency Channel Plan A 5735 and 5804 MHz Frequency Channel Plan B 5753 and 5822 MHz Frequency Channel Plan C 5771 and 5840 MHz Transmission...

Страница 66: ...5 4 1 1 2 or 4 i e nE1 Interface Data Rate Full duplex E1 2 048Mbit s 2E1 or 4E1 Digital Interface ITU T G 703 Connectors Balanced 110 ohm on DB25 Line code HDB3 or AMI selectable Jitter and Wander I...

Страница 67: ...Hardware Port rate 115 200 bps 8 5 8 Element Manager Port Interface Interface standard RS232 DTE Handshaking Hardware Data rate 115 200 bps 8 5 9 Indoor Outdoor Unit Interface The physical interface...

Страница 68: ...T 5 P N 18 241 31 18 241 11 5 1mm 3 General Cable CAT 5 P N 2137113 2137114 5 6mm 4 Belden CAT 5 P N BC1002 6 0mm Option 1 is the preferred choice For the cables that have diameters less the required...

Страница 69: ...Outdoor Unit Type N RF output high power output for FCC and unregulated Full 4xE1 4xT1 4x2Mbps or 4x1 5Mbps data interface MDR5800 operates from 21 56VDC optional 110 220VAC power supply available bel...

Страница 70: ...r Unit 2xE1 T1 Spare Part 651 03810ET4 MDR5800 Indoor Unit 4xE1 T1 Spare Part 651 03806LB MDR5800 Low Band Outdoor Unit Spare Part 651 03806HB MDR5800 High Band Outdoor Unit Spare Part 651 03868 MDR58...

Страница 71: ...xE1 T1or 2xE1 T1 or 4xE1 T1 1 651 03806HB or 651 03806LB MDR5800 Outdoor unit 1 651 03809 MDR 5800 ODU Pole Mounting Kit 1 862 01881 MDR5800 Digital Radio System User Manual 1 651 03868 NMS Software D...

Страница 72: ...tween a computer and the MDR5800 Indoor Unit s Element Manager port It lists how the connection can be setup and configured to allow data transfer and SNMP based control of the MDR5800 Indoor Unit Not...

Страница 73: ...MDR5800 User Manual 862 01881 Issue 6 Page 73 9 1 Adding a Modem Windows NT 1 When working with a PC running a Windows NT add a modem using the following screen as a guideline...

Страница 74: ...MDR5800 User Manual 862 01881 Issue 6 Page 74...

Страница 75: ...MDR5800 User Manual 862 01881 Issue 6 Page 75 2 Select the COM port to use push the Next when the COM port has been selected...

Страница 76: ...MDR5800 User Manual 862 01881 Issue 6 Page 76...

Страница 77: ...01881 Issue 6 Page 77 9 2 Adding Dial up Networking Windows NT 9 2 1 To add dial up networking 1 From the desktop open the My Computer icon and double click the Dial up Networking icon 2 The followin...

Страница 78: ...ssue 6 Page 78 3 Whether COM1 or COM2 is selected setup the connection using the following screens as a guideline This allows establishment of a PPP connection between the computer and the MDR5800 Ind...

Страница 79: ...MDR5800 User Manual 862 01881 Issue 6 Page 79...

Страница 80: ...MDR5800 User Manual 862 01881 Issue 6 Page 80...

Страница 81: ...MDR5800 User Manual 862 01881 Issue 6 Page 81...

Страница 82: ...MDR5800 User Manual 862 01881 Issue 6 Page 82 9 3 Adding a Modem Windows 95 98 1 When working with a PC running a Windows 95 98 add a modem using the following screen as a guideline...

Страница 83: ...0 User Manual 862 01881 Issue 6 Page 83 3 Use the mdmnull inf to add a serial cable modem connection capability to the PC or laptop 4 Once setup use the following screens to set up the COM port s para...

Страница 84: ...MDR5800 User Manual 862 01881 Issue 6 Page 84...

Страница 85: ...em set up the connection properties using the following screens as a guideline This will allow establishment of a PPP connection between the computer and the MDR5800 Indoor Unit s Element Manager port...

Страница 86: ...MDR5800 User Manual 862 01881 Issue 6 Page 86...

Страница 87: ...from any remote location The product can be accessed via the Internet if the necessary gateways are provided A GSM PCS modem dial up capability provides another remote management option The MDR Indoo...

Страница 88: ...tion From the Management station the agents within the MDR Indoor Units can be configured or polled for information 2 Agent The agent accepts SNMP GET SET or GET NEXT commands from the Management Appl...

Страница 89: ...TEGER read only An Alarm Indication Signal has been detected on the input to a tributary there are four one for each tributary 1 3 6 1 4 1 1316 1 1 1 1 2 mdrmteRFLinkPerf 1 3 6 1 4 1 1316 1 1 1 1 2 1...

Страница 90: ...rrSecRatioExceeded INTEGER read only The ESR is a ratio of the number of Errored seconds one second periods within which uncorrectable packets were counted by the FEC IC to the total time in seconds 1...

Страница 91: ...talSeconds Counter read only Indicates the total number of seconds both available and unavailable 1 3 6 1 4 1 1316 1 1 1 1 3 3 mdrmteAvailableSeconds Counter read only A period of unavailable time beg...

Страница 92: ...rite only Reset all parameters associated with Packet Error and G 826 measurements for the RF Link 1 3 6 1 4 1 1316 1 1 1 2 mdrmteConfiguration 1 3 6 1 4 1 1316 1 1 1 2 1 MdrmtePayloadConf 1 3 6 1 4 1...

Страница 93: ...AN D OPTION IS SELECTED VIA THE MIB 1 3 6 1 4 1 1316 1 1 1 2 2 4 mdrmteRxFrequencyPlanD INTEGER read write Refer to the mdrmteTxFrequencyPlanD description 1 3 6 1 4 1 1316 1 1 1 2 2 5 mdrmteTransmitBa...

Страница 94: ...not enabled this allows control of the Outdoor Unit Plan D frequencies without the auto recovery feature attempting to intervene and re establish setup of an operational RF Link 1 3 6 1 4 1 1316 1 1...

Страница 95: ...irmware that loaded into the product s Boot Flash 1 3 6 1 4 1 1316 1 1 1 2 4 5 mdrmteOUSerialNumber INTEGER read only The Outdoor Serial Number is programmed into the OU at time of manufacture and is...

Страница 96: ...1 3 6 1 4 1 1316 1 1 1 2 5 2 mdrmteFlashNewFirmware INTEGER read write This entry determines the time when the new version of firmware will be activated 1 3 6 1 4 1 1316 1 1 1 3 mdrmteFault 1 3 6 1 4...

Страница 97: ...2 3 mdrmteSRAM INTEGER read only Identifies pass fail status of the Indoor Unit s Static RAM 1 3 6 1 4 1 1316 1 1 1 3 2 4 mdrmteLineInterface INTEGER read only Identifies pass fail status of the Indoo...

Страница 98: ...mdrmteCriticalPERThreshold DisplayString read write Defines the threshold used as a checking criterion for the Critical PER Packet Error Rate 1 3 6 1 4 1 1316 1 1 1 3 4 4 mdrmteErrSecRatioThreshold D...

Страница 99: ...an Indoor Unit using IP 1 3 6 1 4 1 1316 1 1 1 4 5 mdrmteNumActiveUsers Gauge read only If the firmware is built with the security feature switched on users can log into an IU This entry defines the...

Страница 100: ...PP port 1 3 6 1 4 1 1316 1 1 1 4 12 MdrmteIPNegotiable INTEGER read write Determines if the local PPP IP address is negotiable or not does not need to be adjusted by the user 1 3 6 1 4 1 1316 1 1 1 4...

Страница 101: ...INTEGER read write Defines if the script is active or not for remote relay activation 1 3 6 1 4 1 1316 1 1 1 5 2 mdrmteRelay2 1 3 6 1 4 1 1316 1 1 1 5 2 1 mdrmteRelay2Label DisplayString read write A...

Страница 102: ...rmteTrapUndefined Informational 2 MdrmteTrapPayloadLOS Critical Indicates a Loss of Signal identified on the INPUT TO a tributary 3 MdrmteTrapPayloadAIS Critical Indicates an Alarm Indication Signal a...

Страница 103: ...TrapUserDeleteFailed Informational With security MODE ON indicates there was an attempt to remove delete a user but the attempt failed 32 MdrmteTrapUserLogIn Informational With security MODE ON indica...

Страница 104: ...RelayScriptDisable Relay scripting is disabled 57 MdrmteTrapGetEventLog Informational Indoor Unit s event log is being accessed 58 MdrmteTrapClearEventLog Informational Indoor Unit s event log is bein...

Страница 105: ...RS232 PPP WIRELESS PPP RS232 Ethernet 10 BaseT NEAR FAR Laptop computer Browser NMS 10 2 1 3 Hub MDR 5800 ROUTING CONFIGURATION Laptop computer Browser NMS 10 12 1 2 Laptop computer Browser NMS 10 13...

Страница 106: ...reen printout of the routes the PC is using use the command line entry route print NOTE DO NOT ALLOW AN RF LINK TO ESTABLISH BEFORE DOING A PING on the remote IU with 10 11 1 2 as an IP address if the...

Страница 107: ...168 2 2 192 168 4 3 10 11 1 2 R 192 168 1 3 B 192 168 3 3 Ethernet 10 BaseT PPP RS232 PPP WIRELESS PPP RS232 Ethernet 10 BaseT NEAR FAR Laptop computer Browser NMS 10 2 1 3 R 192 168 1 4 B Hub MDR 58...

Страница 108: ...hardware and firmware Version 2 x firmware has 1 FTP upload functionality needs to be activated via the MIB 2 IP Bridging functionality half and full duplex selectable via the MIB 3 Band Plan C 4 Refe...

Страница 109: ...f the professional installer to ensure that when using the outdoor antenna kits in the United States or where FCC rules apply only these antenna configurations shown in the table in section 1 4 are us...

Отзывы: