6. Assignment of ID Addresses
When performing parallel communication operation of multiple machines, you need to configure the dialing
address of each PACK first. When the BMS is configured for stand-alone operation, and the dialing address
can be any address; when the BMS is configured for cascade operation mode, the slave dialing address is
selected from 1 to 31, and the host dialing address is selected from 32 or 48 according to the inverter brand.
You can enter the address code of the master or slave battery in the system parameters of the upper
computer to detect and communicate.
Code
ADD
PACK
NO.
Remarks
1
2
3
4
5
6
ON
OFF
OFF
OFF
OFF
OFF
1
PACK 1
Slave Pack
OFF
ON
OFF
OFF
OFF
OFF
2
PACK 2
ON
ON
OFF
OFF
OFF
OFF
3
PACK 3
OFF
OFF
ON
OFF
OFF
OFF
4
PACK 4
ON
OFF
ON
OFF
OFF
OFF
5
PACK 5
OFF
ON
ON
OFF
OFF
OFF
6
PACK 6
ON
ON
ON
OFF
OFF
OFF
7
PACK 7
OFF
OFF
OFF
ON
OFF
OFF
8
PACK 8
ON
OFF
OFF
ON
OFF
OFF
9
PACK 9
OFF
ON
OFF
ON
OFF
OFF
10
PACK 10
ON
ON
OFF
ON
OFF
OFF
11
PACK 11
OFF
OFF
ON
ON
OFF
OFF
12
PACK 12
ON
OFF
ON
ON
OFF
OFF
13
PACK 13
OFF
ON
ON
ON
OFF
OFF
14
PACK 14
ON
ON
ON
ON
OFF
OFF
15
PACK 15
OFF
OFF
OFF
OFF
ON
OFF
16
PACK 16
ON
OFF
OFF
OFF
ON
OFF
17
PACK 17
OFF
ON
OFF
OFF
ON
OFF
18
PACK 18
ON
ON
OFF
OFF
ON
OFF
19
PACK 19
OFF
OFF
ON
OFF
ON
OFF
20
PACK 20
ON
OFF
ON
OFF
ON
OFF
21
PACK 21
OFF
ON
ON
OFF
ON
OFF
22
PACK 22
ON
ON
ON
OFF
ON
OFF
23
PACK 23
OFF
OFF
OFF
ON
ON
OFF
24
PACK 24
ON
OFF
OFF
ON
ON
OFF
25
PACK 25
OFF
ON
OFF
ON
ON
OFF
26
PACK 26
ON
ON
OFF
ON
ON
OFF
27
PACK 27
OFF
OFF
ON
ON
ON
OFF
28
PACK 28
ON
OFF
ON
ON
ON
OFF
29
PACK 29
OFF
ON
ON
ON
ON
OFF
30
PACK 30
ON
ON
ON
ON
ON
OFF
31
PACK 31
OFF
OFF
OFF
OFF
OFF
ON
32
PACK 32
Master Pack
: if your inverter is from other brands except
Victron, SMA and Growatt, the ADD of master pack is 32
OFF
OFF
OFF
OFF
ON
ON
48
Master Pack
: if your inverter is from Victron, SMA or
Growatt, the ADD of master pack is 48