7077-801F • 08/20
6
F. Mobile Home Approved
•
This appliance is approved for mobile home installations
when not installed in a sleeping room and when an
outside combustion air inlet is provided.
•
The structural integrity of the mobile home floor, ceiling,
and walls must be maintained.
•
The appliance must be properly grounded to the frame
of the mobile home with #8 copper ground wire, and use
only listed double-wall connector pipe.
•
Outside Air Kit provided with each unit must be installed
in a mobile home installation.
D. Glass Specifications
This appliance is equipped with 5mm ceramic glass.
Replace glass only with 5mm ceramic glass. Please
contact GHP for replacement glass.
E. Electrical Rating (On High)
WARNING
This product and the fuels used to operate this product (wood), and
the products of combustion of such fuels, can expose you to
chemicals including carbon black, which is known to the State of
California to cause cancer, and carbon monoxide, which is known to
the State of California to cause birth defects or other reproductive
harm. For more information go to: WWW.P65Warnings.ca.gov
NOTE:
This appliance is approved for installation in
a workshop.
Model
Electrical Rating
PH35PS-B
115 VAC, 60 Hz, Start 2.6 Amps,
Run 0.9 Amps
PH50PS-B
PH50CABPS-B
I. Sleeping Room
When installed in a sleeping room it is recommended that
3ft of vertical be installed prior to horizontally exiting the
room and a smoke/CO alarm be installed in the bedroom.
The size of the room must be at least 50ft³ per 1,000 Btu/hr
stove input, if the stove exceeds the room size, outside air
must be installed.
J. California - PROP65
G. Non-Combustible Materials
Material which will not ignite and burn, composed of any
combination of the following:
-
Steel
-
Plaster
-
Brick
-
Iron
-
Concrete
-
Tile
-
Glass
-
Slate
Materials reported as passing
ASTM E 136, Standard
Test Method for Behavior of Metals, in a Vertical Tube
Furnace of 750° C.
H. Combustible Materials
Material made of/or surfaced with any of the
following materials:
-
Wood
-
Compressed Paper
-
Plant Fibers
-
Plastic
-
Plywood/OSB
-
Sheet Rock (drywall)
Any material that can ignite and burn: flame proofed or not,
plastered or non-plastered.
WARNING
!
Risk of Fire.
GHP disclaims any responsibility for, and the
warranty and agency listing will be voided by
the below actions.
DO NOT:
•
Install or operate damaged appliance
•
Modify appliance
•
Install other than as instructed by the manufacturer.
•
Operate the appliance without fully assembling all
components
•
Over fire
•
Install any component not approved by the
manufacturer
•
Install parts or components not Listed or approved
•
Disable safety switches
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.