Playworld Systems XX0365 Скачать руководство пользователя страница 15

Guidelines & Information (fs SPE_noslide)

 Annex Page 1 of 7

Guidelines

Important ! Please Read Completely Before Beginning Installation. 

According 

to a report published by the U. S. Consumer Product Safety Commission (C.P.S.C.) 
72% of all playground injuries result from accidental falls. With this in mind, this 
equipment is designed to fi ll the need for safe yet challenging play. In conjunction 
with design efforts to reduce the possibilities of injuries, this equipment 

must

 

be installed "Step by Step" per our installation instructions. As a new owner you 
are responsible for the correct installation, safe use, and maintenance of your 
equipment.

Installation Guidelines
• 

Identify all parts and thoroughly read the assembly instructions before 

beginning construction.

• 

Refer to your playground equipment plan and footing diagram to assure 

the equipment purchased

 

will fi t into your selected site area. The use and no-

encroachment zones around the play equipment shall be obstacle-free areas 
designated for unrestricted circulation.

• ASTM 

compliance: 

The overall use zone measurements for stationary play 

equipment should extend a minimum of 72 inches (1829 mm) from its perimeter; 
dimensions and confi guration of the use zone are dependent upon the types of 
included play equipment. The use zone of stationary play equipment may be 
overlapped by the use zone of adjacent stationary play equipment if the adjacent 
designated play surfaces are no greater than 30 inches (762 mm) above the 
protective surfacing level. They should be a minimum of 72 inches (1829 mm) 
apart. If the adjacent designated play surfaces are greater than 30 inches (762 
mm) above the protective surfacing level, the pieces of equipment should be a 
minimum of 108 inches (2743 mm) apart. 

• CSA 

compliance: 

The overall use zone measurements for stationary play 

equipment should extend a minimum of 1800 mm from its perimeter; dimensions 
and confi guration of the use zone are dependent upon the types of included play 
equipment. The use zone of stationary play equipment may be overlapped by the 
use zone of adjacent stationary play equipment if the adjacent designated play 
surfaces are no greater than 700 mm above the protective surfacing level. They 
should be a minimum of 1800 mm apart. 

• EN 

compliance: 

The overall use zone measurements for stationary play 

equipment are dependent upon the fall height of the equipment. For a fall height 
exceeding 1500 mm a formula is applied to determine the use zone (impact zone) 
of the equipment. There is a minimum of 1500 mm from its perimeter; dimensions 
and confi guration of the use zone are dependent upon the types of included play 
equipment. Refer to the Use Zone diagram or master structure drawing.

• 

Site layout is a critical part of the overall installation. Footings must be 

measured and marked accurately according to the footing diagram. A level and 
clear installation site is ideal.

• 

Good drainage around the structure and its supports is important. Inquire with 

local contractors for appropriate recommendations.

• 

After laying out all footings and before digging holes, be sure to inquire about 

underground utilities that may exist.

• 

Do not leave the job site unattended without making sure that all fastening 

hardware on all components are tightened according to tightening torque 
specifi cations listed on every installation guide. We also recommend roping off 
construction area and covering all holes that do not contain a piece of equipment 
with plywood or other suitable material.

• 

Excavate holes as shown in the footing detail. If a level and clear site cannot 

be obtained, adjust the depth of footing to maintain a level footing base. If soil 
conditions are loose or unstable, a larger diameter footing may be required. Inquire 
with local contractors for appropriate recommendations. Be sure concrete that 
might have splashed onto the unit is washed off before it dries. Allow concrete to 
harden 72 hours before allowing your structure to be used. 

Assemble the entire 

structure before pouring concrete unless specifi cally instructed to do so in 
the installation instructions.

• 

Insure that Age Appropriate and Hard Surface Warning/Playworld Systems 

identifi cation labels are properly affi xed to the play equipment. Labels are to be 
plainly visible according to current playground equipment guidelines.

Содержание XX0365

Страница 1: ...surface mount Concrete Required 0 12 cubic yard 0 09 cubic meters Use Zone Refer to the information below User Group Age years ASTM CSA 2 12 EN 2 14 Assembly View representative model ICON KEY Fully...

Страница 2: ...XX3170 and XX3170S ECN2382 Page 2 of 14 Top View Elevation Views XX3170 Footing Diagram 12 6 320 mm KEY Position Unit of Measurement Top Inches Bottom Millimeters Apply Surfacing Warning Labels Here...

Страница 3: ...XX3170 and XX3170S ECN2382 Page 3 of 14 Top View Elevation Views XX3170S Footing Diagram KEY Position Unit of Measurement Top Inches Bottom Millimeters 12 6 320 mm Apply Surfacing Warning Labels Here...

Страница 4: ...06645 8 Total Wheel Cover BFC0307 4 Total 12 Dia Wheel BFC0303 4 Total 3 8 Button Head Nut BAE0663 8 Total Window Panel BFC0294 1 Total Important Note Place the wheels on the opposite side of the wind...

Страница 5: ...blies to the support posts Note The side of the panels with the wheels must be facing out Detail D Step 7 Attach the backrests to the support posts Backrest BFC0292 2 Total 3 8 x 3 4 Button Head Bolt...

Страница 6: ...etail E Step 8 Attach the seat planks to the panels Seat Plank BPM0258 2 Total 3 8 x 1 1 2 Button Head Bolt BAE06645 8 Total 1 O D Flat Washer BAE0600 8 Total 3 8 Lock Nut BAE0620 8 Total Detail F Ste...

Страница 7: ...Nut BAE0161 8 Total 1 4 Flat Washer BAE0158 8 Total Detail H Step 11 Attach the table support to the table 3 8 x 2 1 2 Button Head Bolt BAE0668 1 Total 1 O D Flat Washer BAE0600 1 Total Table BPM0259...

Страница 8: ...port to the roof 3 8 x 3 4 Button Head Bolt BAE0659 1 Total 1 O D Flat Washer BAE0600 2 Total 3 8 Lock Nut BAE0620 1 Total Detail K Step 14 Attach the roof trim to the roof Roof Trim BFC0295 2 Total 1...

Страница 9: ...lign with the holes over the wheels and attach as shown Step 9 Attach the logo plate to the window panel See Detail F Position the logo plate over the center of the window panel align the holes and at...

Страница 10: ...ON HEAD SS 9 BAE0663 NUT 3 8 16 x 7 16 BUTTON HEAD SS 16 BAE0666 BOLT 3 8 16 x 1 1 4 BUTTON HEAD SS 16 BAE0668 BOLT 3 8 16 x 2 1 2 BUTTON HEAD SS 1 BAE0900 WRENCH 5 32 SHORT HEX KEY 1 BAE0902 TOOL 7 3...

Страница 11: ...FLAT 21 BAE0620 NUT 3 8 16 LOCK w NYLON CAP 11 BAE0659 BOLT 3 8 16 x 3 4 BUTTON HEAD SS 9 BAE0663 NUT 3 8 16 x 7 16 BUTTON HEAD SS 16 BAE0666 BOLT 3 8 16 x 1 1 4 BUTTON HEAD SS 16 BAE0668 BOLT 3 8 16...

Страница 12: ...Installation Instructions Models XX3170 and XX3170S ECN2382 Page 12 of 14 This page is intentionally left blank...

Страница 13: ...detected barricade equipment to prevent use until repair is completed Contact your sales representative immediately for a replacement part Finish Inspect metal parts for finish damage To repair paint...

Страница 14: ...ty s Sake Repairer Name Please Print __________________________________ Signature ________________________________________ Date ___ ___ ___ MAINTENANCE SCHEDULE Item in Question Description of Problem...

Страница 15: ...ne of adjacent stationary play equipment if the adjacent designated play surfaces are no greater than 700 mm above the protective surfacing level They should be a minimum of 1800 mm apart EN complianc...

Страница 16: ...post hole digger steel rake wheelbarrow garden hoe water hose tape measure level alignment tool 3 8 ratchet with 9 16 socket and 9 16 combination wrench Maintenance Inadequate maintenance of equipment...

Страница 17: ...oting Detail Support Post EN 2 51 mm 18 457 mm Diameter Varies 42 1067 mm Varies 36 914 mm Support Post Footing Detail ASTM CSA Ground Level Concrete Protective Surfacing Level Factory Applied Protect...

Страница 18: ...Protective Surfacing Level Sticker End Cap from Post Shipping Tube Drill holes in cap to allow for water drainage Support Post 2b Stone 2 51 mm 12 305 mm Diameter Varies 30 762 mm Varies 24 610 mm Co...

Страница 19: ...evel at the lowest grade Adjust other footings accordingly Support posts and all attaching decks and play components must be plumb and level Do not encase the bottom of the support post in concrete Pl...

Страница 20: ...the protective surfacing level at the lowest grade Adjust other footings accordingly Support posts and all attaching decks and play components must be plumb and level The footing size may vary due to...

Страница 21: ...height dimensions Height measurements are taken from the top of the protective surfacing material Insure all fasteners are tightened according to tightening torque specifications listed on your instal...

Отзывы: