Playworld Systems UN8727 Скачать руководство пользователя страница 13

Guidelines & Information (fs SPE_noslide)

 Annex Page 1 of 7

Guidelines

Important ! Please Read Completely Before Beginning Installation. 

According 

to a report published by the U. S. Consumer Product Safety Commission (C.P.S.C.) 

72% of all playground injuries result from accidental falls. With this in mind, this 

equipment is designed to fill the need for safe yet challenging play. In conjunction 

with design efforts to reduce the possibilities of injuries, this equipment 

must

 

be installed "Step by Step" per our installation instructions. As a new owner you 

are responsible for the correct installation, safe use, and maintenance of your 

equipment.

Installation Guidelines

• 

Identify  all  parts  and  thoroughly  read  the  assembly  instructions  before 

beginning construction.

• 

Refer to your playground equipment plan and footing diagram to assure 

the equipment purchased

 

will fit into your selected site area. The use and no-

encroachment  zones  around  the  play  equipment  shall  be  obstacle-free  areas 

designated for unrestricted circulation.

•  ASTM compliance: 

The overall use zone measurements for stationary play 

equipment should extend a minimum of 72 inches (1829 mm) from its perimeter; 

dimensions and configuration of the use zone are dependent upon the types of 
included  play  equipment. The  use  zone  of  stationary  play  equipment  may  be 
overlapped by the use zone of adjacent stationary play equipment if the adjacent 
designated  play  surfaces  are  no  greater  than  30  inches  (762  mm)  above  the 
protective surfacing level. They should be a minimum of 72 inches (1829 mm) 
apart. If the adjacent designated play surfaces are greater than 30 inches (762 
mm) above the protective surfacing level, the pieces of equipment should be a 

minimum of 108 inches (2743 mm) apart. 

•  CSA compliance: 

The overall use zone measurements for stationary play 

equipment should extend a minimum of 1800 mm from its perimeter; dimensions 

and configuration of the use zone are dependent upon the types of included play 
equipment. The use zone of stationary play equipment may be overlapped by the 

use zone of adjacent stationary play equipment if the adjacent designated play 

surfaces are no greater than 700 mm above the protective surfacing level. They 

should be a minimum of 1800 mm apart. 

•  EN compliance: 

The  overall  use  zone  measurements  for  stationary  play 

equipment are dependent upon the fall height of the equipment. For a fall height 

exceeding 1500 mm a formula is applied to determine the use zone (impact zone) 

of the equipment. There is a minimum of 1500 mm from its perimeter; dimensions 
and configuration of the use zone are dependent upon the types of included play 

equipment. Refer to the Use Zone diagram or master structure drawing.

• 

Site  layout  is  a  critical  part  of  the  overall  installation.  Footings  must  be 

measured and marked accurately according to the footing diagram. A level and 

clear installation site is ideal.

• 

Good drainage around the structure and its supports is important. Inquire with 

local contractors for appropriate recommendations.

• 

After laying out all footings and before digging holes, be sure to inquire about 

underground utilities that may exist.

• 

Do not leave the job site unattended without making sure that all fastening 

hardware on all components are tightened according to tightening torque 

specifications listed on every installation guide. We also recommend roping off 
construction area and covering all holes that do not contain a piece of equipment 

with plywood or other suitable material.

• 

Excavate holes as shown in the footing detail. If a level and clear site cannot 

be obtained, adjust the depth of footing to maintain a level footing base. If soil 
conditions are loose or unstable, a larger diameter footing may be required. Inquire 

with local contractors for appropriate recommendations. Be sure concrete that 

might have splashed onto the unit is washed off before it dries. Allow concrete to 

harden 72 hours before allowing your structure to be used. 

Assemble the entire 

structure before pouring concrete unless specifically instructed to do so in 

the installation instructions.

• 

Insure that Age Appropriate and Hard Surface Warning/Playworld Systems 

identification labels are properly affixed to the play equipment. Labels are to be 
plainly visible according to current playground equipment guidelines.

Содержание UN8727

Страница 1: ...ime In Ground 1 5 man hours Installation Time Surface Mount 1 man hour Concrete Required 0 12 cubic yard 0 09 cubic meters Use Zone See the master layout drawing User Group Age single cube ASTM CSA 2 12 EN 2 14 User Group Age multiple cubes ASTM CSA 5 12 EN 6 14 Assembly View representative model ICON KEY Fully Tighten Hardware Add 1 Drop of Thread Locking Adhesive Do Not Fully Tighten Hardware Po...

Страница 2: ...structions Models UN8727 and UN8727S PA1395 ECN2643 Page 2 of 12 Top View Elevation Views UN8727 Footing Diagram 49 1245 mm Footed as shown KEY Position Unit of Measurement Top Inches Bottom Millimeters 0 1 0 1 685 9 ...

Страница 3: ...uctions Models UN8727 and UN8727S PA1395 ECN2643 Page 3 of 12 Elevation Views UN8727S Footing Diagram KEY Position Unit of Measurement Top Inches Bottom Millimeters Top View 49 1245 mm Footed as shown 685 9 6 1 25 127 6 ...

Страница 4: ...e step descriptions start on page 9 Detail A Step 4 Attach the top cube to the bottom cube Top Cube BPL3186 1 Total Bottom Cube BPL3187 1 Total 3 8 Flat Washer BAE0595 12 Total Plastic Washer half of a two piece assembly BPL0300 12 Total 3 8 x 2 3 4 Button Head Bolt BAE06677 6 Total 3 8 x 1 1 2 Button Head Bolt BAE06645 6 Total Note Large holes in the cubes are offset from each other ...

Страница 5: ... to the bottom cube Anchor Post AFR1820 1 Total Logo Casting AAU0906 1 Total 3 8 x 3 Button Head Bolt BAE06681 3 Total 1 O D Flat Washer BAE0600 6 Total 3 8 Flat Washer BAE0595 3 Total Detail C Step 6 In Ground Model Attach the logo casting to the bottom cube 3 8 x 1 3 4 Button Head Bolt BAE0665 6 Total 3 8 Barrel Nut BAE0632 6 Total ...

Страница 6: ...unt Model Attach the anchor frame to the bottom cube Anchor Frame AFR1874 1 Total 1 O D Flat Washer BAE0600 6 Total 3 8 x 1 3 4 Button Head Bolt BAE0665 6 Total 3 8 Barrel Nut BAE0632 6 Total Note For the surface mount model do not attach the logo casting until the component has been secured on its footing ...

Страница 7: ... Total if not attaching to another cube Detail F Step 10 Fill in the unused holes inside and outside the ground level cube Align rivets as shown so they interlock Logo Casting AAU0906 1 Total 3 8 x 3 Button Head Bolt BAE06681 3 Total 3 8 Flat Washer BAE0595 3 Total Detail E Step 9 Surface Mount Model Attach the logo casting to the bottom cube ...

Страница 8: ...stallation Instructions Models UN8727 and UN8727S PA1395 ECN2643 Page 8 of 12 Plastic Bolt Cap half of a two piece assembly BPL0300 12 Total Detail G Step 11 Insert the bolt caps into the plastice washers ...

Страница 9: ...ame to the bottom cube See Detail D Position the top of the anchor frame against the bottom of the cube assembly and attach as shown Final Details Step 8 Finish assembling the structure Plumb and level the component Tighten all fasteners Fully tighten all fasteners according to tightening torque specifications Torque Specifications Bolts and nuts Snug tighten and then tighten an additional one half ...

Страница 10: ...1 BPL3194 RIVET RATCHET 88 O D x 1 67 36 ALB0025 LABEL AGE APPROPRIATE SHEET 1 UN8727S GROUND LEVEL PLAYCUBE SURFACE MOUNT PART NO DESCRIPTION QTY AU0906 CASTING PLAYCUBES LOGO 1 AFR1874 FRAME 32 48 x 28 67 x 6 35 1 BAD0085 THREAD LOCKING ADHESIVE 1 BAE0595 WASHER 3 8 SAE FLAT 15 BAE0600 WASHER 1 O D FLAT 6 BAE0632 NUT 3 8 16 x 1 25 BARREL w PATCH 6 BAE0665 BOLT 3 8 16 x 1 75 BUTTON HEAD SS 6 BAE0...

Страница 11: ... breakage If any damage is detected barricade the equipment to prevent use until repair is completed Contact your sales representative immediately for a replacement part Welds Inspect all welded joints If any broken welds are detected barricade equipment to prevent use until repair is completed Contact your sales representative immediately for a replacement part Equipment Maintenance Universal Mod...

Страница 12: ... Safety s Sake Repairer Name Please Print __________________________________ Signature ________________________________________ Date ___ ___ ___ MAINTENANCE SCHEDULE Item in Question Description of Problem Corrective Action Date Inspector Name Please Print __________________________________ Signature _________________________________________ Date ___ ___ ___ Inspection Codes P Pass F Fail NA Not A...

Страница 13: ...one of adjacent stationary play equipment if the adjacent designated play surfaces are no greater than 700 mm above the protective surfacing level They should be a minimum of 1800 mm apart EN compliance The overall use zone measurements for stationary play equipment are dependent upon the fall height of the equipment For a fall height exceeding 1500 mm a formula is applied to determine the use zon...

Страница 14: ... post hole digger steel rake wheelbarrow garden hoe water hose tape measure level alignment tool 3 8 ratchet with 9 16 socket and 9 16 combination wrench Maintenance Inadequate maintenance of equipment has resulted in injuries on the playground Because the safety of playground equipment and its stability depends on good inspection and maintenance a comprehensive maintenance program must be develop...

Страница 15: ...es 30 762 mm Varies 24 610 mm Component Footing Detail ASTM CSA Ground Level Concrete Protective Surfacing Level Factory Applied Protective Surfacing Level Sticker Component 2b Stone End Cap from Post Shipping Tube Drill holes in cap to allow for water drainage 400 mm 200 mm 610 mm 760 mm Footing Detail Component Post EN Ground Level Concrete Protective Surfacing Component 2b Stone Factory Applied...

Страница 16: ...ent Footing Detail ASTM CSA Block Option Ground Level Concrete Protective Surfacing Level Factory Applied Protective Surfacing Level Sticker Component Block Porous Material 2 51 mm 18 457 mm Diameter Varies 42 1067 mm Varies 36 914 mm Ground Level Concrete Protective Surfacing Level Factory Applied Protective Surfacing Level Sticker Support Post Block Porous Material Support Post Footing Detail AS...

Страница 17: ...level at the lowest grade Adjust other footings accordingly Support posts and all attaching decks and play components must be plumb and level Do not encase the bottom of the support post in concrete Place the post directly on packed stone or other porous material The footings shown on Playworld Systems documentation are recommendations based on historical performance in average soil conditions Foo...

Страница 18: ...r the protective surfacing level at the lowest grade Adjust other footings accordingly Support posts and all attaching decks and play components must be plumb and level The footing size may vary due to local soil and weather conditions Base of footing must be below frost line Surface mount hardware is not supplied Customer is responsible for concrete base and providing surface mount hardware as sp...

Страница 19: ... height dimensions Height measurements are taken from the top of the protective surfacing material Insure all fasteners are tightened according to tightening torque specifications listed on your installation instructions Insure all exposed pipe ends have properly installed end caps Insure that drive rivets are secure Clean dried concrete off of components and any other affected surface Touch up an...

Отзывы: