background image

T568B is electrically identical to T568A but swaps 
the green and orange pairs. Either standard will 
work as long as the same standard is used at both 
ends of a run or patch cable. Mixing “A” and “B” 
creates a cross-over cable.

The 1–2 pair pins are shorted together, and the 
7–8 pair is open. The pins with the errors are 
flashing. Dash lines (-) on the bottom (remote) 
display line indicate the short, while no numbers 
on the bottom line indicate the open pair.

1 and 2 pins on the MapMaster mini are con-
nected to pins 2 and 1 at the remote-end. The 
pins with this error are flashing. The “U” for the 
remote pin numbers indicates an unrecognizable 
continuity was detected that is neither a short or 
open. An ID remote connected to the MapMaster 
mini when in cable test mode would also show 
this error.

A common error in building a cable is to put all 
the pairs in pin sequence 1–2, 3–4, 5–6 and 
7–8. This will produce the correct continuity, 
but the pairs are designated to be on pins 3–6 
and 4–5 in the middle of the connector for 
compatibility with phone wiring. This wiring error 
is only detected by the split pair test since the 
designated pairs are not twisted together.

• 

Locate:

 Detects network map-only ID remotes #1–#5. 

This mode is not used to test cables but is used only to 
map the location of the jack that the far end is connected 
to using the map-only ID remotes. For testing cables use 
the master remote stored in the bottom of the tester.

• 

Hi Lo 1, Hi Lo 2, Hi, Lo

 (four tone cadences): The four

modes are all tone generator modes with different 
sounds. The “Hi Lo” tones are made up of two frequencies 
with different timings. “Hi” and ”Lo” are single frequency. 
Once in a tone mode, short presses change the pins 
carrying tone. The pins with tone are displayed. In a tone 
mode, the tester will turn off automatically 30 minutes 
after the last button press or by exiting to mode select 
with a long press. Note that you must use an analog tone 
probe to hear the tones generated by the tester.

• 

Off

: When the button is released with “OFF” displayed, 

the Tester will power off. Once in one of the above 
modes, OFF is the first mode offered upon exiting to 
mode select. To select a different mode other than OFF, 
continue to hold the button down and the next mode in 
rotation will be displayed next.

• 

Cable

: The cable test mode is the single cable test mode 

with 20 second timeout that a short press from powered 
off executes.

Warranty

Platinum Tools warrants this product to be free from defects 
in material and workmanship for 12 months for test equip-
ment and 3 months for cables and accessories from the date 
of purchase. Liability is limited to the repair and or replace-
ment of the product. Warranty excludes batteries and wear-
able components such as the integrated RJ45 jack included 
with the product. NO IMPLIED WARRANTIES OF MERCHANT-
ABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Platinum 
Tools is not liable for consequential damages.

Should any parts or workmanship prove defective, Platinum 
Tools will repair or replace at Platinum Tools’ option, at no 
cost to the Buyer except for shipping costs from the Buyer’s 
location to Platinum Tools. This is Buyer’s SOLE AND EXCLU-
SIVE REMEDY under this Agreement. This warranty does not 
apply to products which have been subject to neglect, ac-
cident or improper use, or to units which have been altered 
or repaired by other than an authorized repair facility.

Cleaning

Turn off the MapMaster mini and disconnect all cables. Use 
a damp, clean cloth to clean the MapMaster mini. CAUTION: 
do not use abrasive or harsh cleaners or solvents.

Storage

When the MapMaster mini is not in use, store in a dry, 
protective case. Batteries should be removed if stored for a 
long period of time. Do not expose to high temperatures or 
humidity. When stored in temperatures exceeding the limits 
listed in the Specifications section, allow the MapMaster 
mini to return to normal recommended operating conditions 
before using it.

Disposal

Caution: This symbol indicates that equipment and its 
accessories should be treated to a separate collection and 
proper disposal.

Warning

Always wear approved eye protection. Do NOT use on  
live circuits

Tester

Tester

Tester

Tester

Remote

Remote

Remote

Remote

Properly Wired T568A UTP:

T568A Cable with a Short and Open:

T568A Cable with a Misfire and 

Unrecognized Continuity:

T568A Cable with Split Pairs:

WIRING AND DISPLAY EXAMPLES

WIRING AND DISPLAY EXAMPLES

Test Equipment Depot - 800.517.8431

 