Select
WATER
.
Cooling Water is available to
the Supply manifold.
Purge Air is blocked.
Select
PURGE
.
Purge Air is available to the
Supply manifold.
Cooling Water is blocked.
Select
VENT
.
Press Manual Vent-Drain
Valve. Purge Air is blocked.
Cooling Water is blocked.
For Normal
Processing
To Evacuate
Cooling Water
See Note Below
To Bleed-Off
Trapped Pressure
and Drain
Residual Water
Operation
89mm
3.5"
76mm
3.0"
SWAP
Valve
dia
clearance for
1/4-20 bolts
7.1mm
.28"
Mounting Bracket
Hole Pattern
figure 5
2
Manual Vent
with Drain
[10-32(F)]
Water
Outlet
3/8"NPT(F)
Air Inlet
Water Inlet
WATER
PURGE
VENT
119mm
4.7"
119mm
4.7"
220mm
8.66"
Max.
Height
298mm
11.75"
Max. Operating Width
Dimensions
figure 4
Supply
Water In
Air In
Supply
Water Return
Check
Valve
(Included)
Return Manifold
Supply Manifold
Injection
Mold
Vent
SWAP™
Valve
Optional
Mold
Heater
Mold Heater Bypass
Temporary Hose
Quick-Disconnect
and Ball Valve
Quick-Disconnect
and Ball Valve
Optional Air
Check Valve
(not included)
figure 3
Alternate Closed Loop Installation
Without Air Separator