Plastica iFlo Series Скачать руководство пользователя страница 3

4

1

1. General

This manual provides information relating to the installation, use and
maintenance of this pump.
We recommend that you read it and keep for future reference.
These self priming centrifugal pumps are for permanently installed pools and
must be fixed horizontaly. Installing a non-return device will result in immediate
priming. For the pumps to function correctly, the water temperature must not
exceed 35˚C. The materials used in our pumps have undergone stringent
hydraulic tests and electrical inspections.
Read this manual carefully before installing the pump. It must be installed in
accordance with current regulations and procedures.
We decline all responsibilty for the consequences of failure to comply with the
electrical connection diagrams in avoiding overload of the pump motor.

EVIDENCE OF CONFORMITY
These products are complied with the following directives:
Electromagnetic Compatibility 2004/108/EC, Low voltage 2006/95/EC and two
European Standards.
EN 60335-1 and EN 60335-2-41

Directive WEEE decretive 2002/96/EC, ROHS directive 2002/95/EC.

1. Drain Plug
2. Pump Body
3. Water Input

Connection

4. Nut
5. Water Output

Connection

6. Nut
7. Terminal Box
8. Motor
9. Base

This appliance is not intended for use by persons (including children)

with reduced physical, sensory or mental capabilities, or lack of

experience and knowledge, unless they have been given supervision or

instruction concerning use of the appliance by a person responsible for

their safety. Children should be supervised to ensure that they do not

play with the appliance.

5. Starting the Pump

1. Check that the mains power voltage and frequency correspond to those

indicated on the identification plate on the pump.

2. Check that the pump shaft turns freely.
3. Unscrew the pump lid and fill the pump with water up to the lower level of the

suction pipe.

4. Screw the lid firmly back in place.
5. If the motor does not start or if no water is extracted, refer to the table of

possible failures and remedies on the following pages.

6. Never operate the pump when there is no water present or with the water

inlet blocked. The pump should not be run dry.

7. After filling the pump with water, open all the suction and delivery valves and

start the motor. Wait for self-priming to take place. The pump is correctly
primed when the water level is just below the transparent cover.

6. Servicing

Our pumps require no particular servicing. It is nevertheless recommended to
clean the pre-filter periodically. This is a simple operation, close the suction and
delivery valves, loosen the black nuts and remove the pre-filter cover gasket
and replace it if damaged. If the pump is not used over the winter period, it
must be emptied (by opening the drain plug) to avoid damage through
freezing, cleaned and stored in a dry and well ventilated area. In the event of
failure, do not try to repair the pump, seek professional advice.
Be sure to disconnect the pump from the electric supply before any
servicing is carried out.