Figure 14 Call Handling Web Page Settings
Web Page: Call Handling
Label on web page:
Automatically Dial Number
Parameter name: AUTO_DIAL_NUMBER
Type: string (up to 40 chars)
Default Value: ""
Notes: The number or URI to call when the Answer/End button is pressed during the
idle state. If no domain is provided, the domain from SRV_0_SIP_UA_DATA_DOMAIN
will be added.
Web Page: Call Handling
Label on web page:
Automatically Answer
Parameter name: CALL_AUTO_ANSWER
Type: Boolean
Default Value: 0 (Disable)
Notes: Determines if IP40 headset adapter will answer (respond with 200 OK) or ring
(respond with 180 Ringing) to incoming call.
Web Page: Call Handling
Label on web page:
Disconnect Button
Parameter name: DISCONNECT_BUTTON
Type: Boolean
Default Value: 1 (Enable)
Notes: Determine if the IP40 headset adapter will be able to send BYE and CANCEL
requests. If this feature is disabled, the user will only be able to disconnect a call using
third party software on a PC for example.