background image

Copyright Planika Sp. z o.o.  

www.planikafires.com 

 

i1111#03 

02.11.2017 

 

!

 

 

Do not install the device in areas with a capacity of less than 58 m

3

 / 2048 ft

3

 (22 m

2

 / 237 

ft

2

 with a height of 2.6 m / 8.53 ft).

 

 

While installing the device according to the instruction manual local and national 

guidelines are to be observed. 

 

Place the device on a levelled surface. The cavity for the device has to be designed with 

the use of a spirit level. 

 

Do not obstruct the ventilation slots and/or ventilators. 

 

Do not install the device in areas of large drafts of air, near fans, vents, etc. 

 

Do  not  place  in  areas  where  there  might  be  a  potentially  explosive  atmosphere  of  paint 

vapours, industrial dusts, etc.

 

 

No flammable items should be placed in direct contact and within a 1 m / 3.28 ft from the 

device. Do not place near curtains, net curtains, etc. 

 

Do not expose the device to meteorological conditions. The device is for indoor use only. 

 

Do not place the device in close proximity to sources of humidity. 

 

It is obligatory to have a carbon-dioxide (CO

2

) or dry chemical extinguisher placed nearby 

the device. 

 

The room in which the device will be installed must have efficient ventilation to ensure air 

exchange in the room at least once per hour. 

 

Do not start the device before a complete and proper installation. 

 

Do not fill the fuel container before placing the product into its final position.

 

 

In case of mounting more than one unit in the room, the minimal cubature is the sum of 

cubatures required for each unit.

 

 

The  bearing  capacity  of  the  substrate,  on  which  the  device  will  be  installed,  must  be  at 

least 77 kg / 169,8 lb. 

 

The device must be place out of reach of: children, animals and unauthorized persons.. 

 

Do not install the device in mobile facilities (e.g. trailers, yachts). 

Содержание PrimeBox

Страница 1: ... 1 D E x 3 x 3 F G x 3 x 1 H I J x 1 x 1 x 1 O5x20 M6x52 O8x60 H H1 H2 D4 D2 D3 H1 H L2 L1 L2 D L D1 mm H 865 34 1 16 H1 715 28 1 8 H2 150 5 7 8 L 875 34 7 16 L1 762 30 L2 56 5 2 1 4 D 335 13 3 16 D1 320 12 5 8 D2 274 10 13 16 D3 26 1 D4 20 13 16 Fixed unit s weight 38 5 kg 84 9 lb Adapter AC Service Kit Automatic fuel pump ...

Страница 2: ...vice Do not place near curtains net curtains etc Do not expose the device to meteorological conditions The device is for indoor use only Do not place the device in close proximity to sources of humidity It is obligatory to have a carbon dioxide CO2 or dry chemical extinguisher placed nearby the device The room in which the device will be installed must have efficient ventilation to ensure air exch...

Страница 3: ... plasterboard or wood The wall can be covered with any paint Wallpaper is forbidden behind the unit but above acceptable Due to fire safety under no circumstances can there be placed any flammable materials within a 1 m 40 inches from the device min 1000 mm min 39 3 8 min 1000 mm min 39 3 8 min 1000 mm min 39 3 8 min 1000 mm min 39 3 8 min 1000 mm min 39 3 8 min 1000 mm min 39 3 8 min 1000 mm min ...

Страница 4: ...ing so use level to make sure that it is applied straight The aim of the bar hanger is to secure the unit from accidental overturn Apply the mounting batten to the wall and level it At the height of 820 mm mark the perforation spots for screws or pegs a Uniform hard surface e g concrete brick C D Ø 8x70mm Ø 5 16 x 2 3 4 D C ...

Страница 5: ...Copyright Planika Sp z o o www planikafires com i1111 03 02 11 2017 5 b The surface of the plasterboard c The surface of the wood Ø 13 mm Ø 1 3 16 E E C 8 16 mm 5 16 5 8 Ø 2x40 mm Ø 1 16 x 1 9 16 C F ...

Страница 6: ...Copyright Planika Sp z o o www planikafires com i1111 03 02 11 2017 6 2 Installation A A 3 Tempered glass installation Tempered glass installation is optional ...

Страница 7: ...u are not allowed to fill the fuel tank and start the device before having read the instruction manual If in the future it is necessary to take the device out of the housing wait until the fuel has burned up completely and the display shows disconnect the power supply and take the device out of the housing Keep this instruction manual throughout the lifetime of the device FUEL ...

Отзывы: