background image

Copyright Planika Sp. z o.o.  

www.planikafires.com 

 

 

 

 

 

 

Information and warning alerts

 

Lp. 

Control Panel 

Indicators 

SOUND 

SIGNALS 

event 

procedure 

co

n

st

a

n

in

te

rm

it

te

n

t

 

 

 

 

If the fire is not visible - NO 
POWER. 

Make sure the device is properly connected to the power 
supply. 

If you see a fire - the device is 
in operation. 

Do not leave the device unattended by an adult. 

 

 

 

The device is ready for 
operation. 

You can run the device in accordance with section B.3 

 

 

 

No fuel in the tank 

Fill the fuel in accordance with B.2 paragraph 

 

 

 

Initial start-up of the device 

Wait for the appearance of fire, the light goes off. 

 

 

 

 
Works protected against too 
rapid restart of the hot device 
or the allowable temperature 
has been exceeded 
 

Allow the  device to cool down. After cooling the  device, 
the red indicator will turn off and the green indicator will 
start to flash. 

 

 

 

The device automatically 
turns off due to lack of fuel in 
the tank. 

Allow the device to cool down. After cooling the device, 
the red indicator will turn off 

 

 

× 

The fuel tank is full. 

It is not allowed to pour any more fuel! Close the Fanola 
filler bolt. The blue indicator will turn off, the green one 
will start to flash. 

 

×

 

 

There was a fuel spill or  

Immediately stop pouring the fuel. Remove the funnel, 
dry a visible moisture. Press the START / STOP button to 
turn off the sound.

 If the spillage is excessive the source 

of power needs to be disconnected. 

With the use of the 

manual pump, supplied by the manufacturer, pump out 
at least 1 litre of fuel from the fuel filler. Wait at least 1 
hour to evaporate the remaining moisture and then close 
the fuel filler bolt. Hold the ECO button for about 5 
seconds. If the alarm message reappears, wait a little bit 
longer until the rest of the moisture evaporates. If the 
message reappears, contact your service provider. 

the acceptable device 
operation temperature has 
been exceeded. 

If the alarm message appears during the start of the 
device, press the START / STOP button to turn off the 
sound and hold the ECO  button for about 5 seconds. 
If the message reappears, contact your service provider. 

 

× 

 

Operation error 

Press the START / STOP button to turn off the sound and 
hold the ECO button for about 5 seconds. 
If the message reappears, contact your service provider. 

10 

 

×

 

 

The device temperature 
below 10°C or critical 
operation error 

Press the START / STOP button to turn off the sound. 
Provide higher ambient temperature. Wait until the 
device obtains the indoor temperature. Hold down the 
ECO button for about 5 seconds. 
If the message reappears, contact your service provider. 

11 

READY

FUEL

HOT

 

×

 

 

Filler bolt protection error. 

Shut the filler bolt. Press the START / STOP button to turn 
off the sound and hold the ECO button for about 5 
seconds. If the message reappears, contact your service 
provider. 

READY

FUEL

HOT

READY

FUEL

HOT

READY

FUEL

HOT

READY

FUEL

HOT

READY

FUEL

HOT

READY

FUEL

HOT

READY

FUEL

HOT

READY

FUEL

HOT

READY

FUEL

HOT

READY

FUEL

HOT

Содержание HotBox

Страница 1: ...USER S MANUAL HotBox Manufactured by Planika Sp z o o ul Bydgoska 38 86 061 Brzoza Poland Edition I0804 04 as of 17 03 2015 ...

Страница 2: ...IS S I IN NS ST TR RU UC CT TI IO ON N M MA AN NU UA AL L TABLE OF CONTENTS I General information 3 II Fuel 3 III Safety 3 IV Operation Operating elements 4 Initial start up of the device 5 Flame size regulation 6 Device extinguishing 6 Subsequent start up 6 Information and warning alert 6 V Cleaning and maintenance 8 VI Disposal and recycling 8 ...

Страница 3: ...r higher than 30 C 86 Fahrenheit Install the device only on a flat horizontal surface Setting on an inclined surface can cause incorrect operation permanent damage to the device or cause fire No flammable items should be placed in direct contact and within a radius of 1 m 3 28 ft around the device Do not place near curtains net curtains etc It is obligatory to have a carbon dioxide or dry chemical...

Страница 4: ...aporates IV Operation This manual contains all the information necessary for the proper operation of the HotBox It is obligatory to read and keep this instruction manual Operation of the device is permitted only after the device is properly installed according to the instructions and the manual A Operating elements START STOP READY FUEL Planika HOT ERROR N E W S E N S O F F I RE PAT PEND ECO Contr...

Страница 5: ...table If the spillage is excessive the source of power needs to be disconnected If 5L containers are used to fill up twist on the cap with the tap onto the container and pour using the funnel To fill up use only accessories provided by the manufacturer 2 4 Pour the fuel to the point where the blue indicator blinks and the intermittent beep will sound Stop pouring Remove the funnel 2 5 Close the Fa...

Страница 6: ... hear two beeps and the red indicator will start to blink The blinking red indicator means that the device is too hot to be restarted When the device cools the message will disappear and depending on the amount of the fuel in the tank either the green indicator will flash and indicate the readiness for operation or the blue indicator will indicate the lack of the fuel E Subsequent start up If on t...

Страница 7: ...e of power needs to be disconnected With the use of the manual pump supplied by the manufacturer pump out at least 1 litre of fuel from the fuel filler Wait at least 1 hour to evaporate the remaining moisture and then close the fuel filler bolt Hold the ECO button for about 5 seconds If the alarm message reappears wait a little bit longer until the rest of the moisture evaporates If the message re...

Страница 8: ...rized persons The manufacturer does not foresee a situation where it will be necessary to clean elements not normally available The manufacturer is not liable for damage resulting from improper operation non manual self dismantling attempts to modify using other liquids than those recommended in point II Fuel VI Disposal and recycling The product is equipped with parts made of aluminium steel plas...

Отзывы: