background image

Copyright Planika Sp. z o.o.  

www.planikafires.com 

 

IG0097#02 

20.02.2018 

 

1.

 

INTRODUCTION 

The GaLiO Insert fireplace is a decorative fuel-effect gas appliances intended only for outdoor use.

 It is obligatory to 

acquaint oneself with the below installation manual and user’s manual before committing to the installation and use 

of the GaLiO Insert fireplace. This manual is to be kept safe for the lifetime of the device. 

 

2.

 

SAFETY INSTRUCTION 

 

Read the instruction before using the device. 

 

Use only outdoors. 

 

The GaLiO Insert is not a free-standing device and is destined to be housed. 

 

The montage of the device must take into account its trouble-free removal in case of service. 

 

Do not start up the device before it’s placed safely into the prepared housing. 

 

The  GaLiO  Insert  fireplace  should  be  installed  and  controlled  annually  according  to  the  below  installation 

manual as well as enforced national and local laws regarding gas safety (installation and use). 

 

One needs to assess whether the data on the product plaque complies with the local type of gas and pressure. 

 

Do not change the structure of the device or its sealed elements nor modify the default settings of the GaLiO 

Insert fireplace. 

 

Do not set any additional imitation blocks nor any glowing coal fragments on the burner or in the combustion 

chamber. 

 

A ventilation grid or slot with a ventilation area of 150cm2 is required at the base of the housing. A device 

without the grid or slot for ventilation will function incorrectly causing a threat of damaging the unit or causing 

a fire. 

 

A CO2 or a powder fire extinguisher needs to be placed near the device. 

 

During the first ignition the GaLiO Insert fireplace needs to be burnt on maximum level for a few hours in order 

for  the  elements  to  acquire  correct  temperature  and  for  the  remains  of  paint,  lacquer  and  lubricant  to 

evaporate. 

 

Do not move the device while it’s working. 

 

The GaLiO Insert fireplace was designed for decorative purposes. The surface of the GaLiO Insert fireplace 

(including the optional glass screens) may get hot (up to 100 degrees Celsius). WARNING!: parts of the device 

that are easy to reach may be very hot. Keep children away from the device. 

 

Some variants of housing for the device may require installing additional toughened glass screens (provided 

separately). 

 

Install the fireplace away from flammable materials.  

 

When the GaLiO Insert fireplace is on it’s not to be exposed to rain. 

 

When not being used the GaLiO Insert is to be protected from atmospheric conditions and the main valve of 

the gas cylinder needs to be turned off. 

 

All parts of the GaLiO Insert fireplace are made of stain resistant material. 

 

Never leave a turned on GaLiO Insert without supervision. 

 

The GaLiO Insert fireplace needs to be installed in a place inaccessible for children, unauthorized persons or 

animals for the direct contact with the flame or hot parts of the device to be impossible. 

 

In case of heavy wind the GaLiO Insert fireplace needs to be immediately turned off and one needs to wait 

until the heavy wind passes. 

 

In case of noticing any sort of gas leaks the fireplace as well as the main valve of the gas cylinder need to be 

turned off. 

 

After use turn off the gas cylinder valve.  

Содержание GaLiO Insert #2

Страница 1: ...ht Planika Sp z o o www planikafires com IG0097 02 20 02 2018 1 USER S MANUAL GaLiO Insert 2 G20 G25 Natural Gas G30 G31 Propane Butane Propane Manufactured by Planika Sp z o o Bydgoska 38 86 061 Brzoza Poland ...

Страница 2: ...NG INSTRUCTIONS 5 3 1 General Notes 5 3 2 Installing the control unit Wall Switch 5 3 3 Replacing the batteries 6 3 4 Operating 8 3 4 1 Automatic Turn Down To Pilot 9 3 4 2 Automatic Shut Off 9 4 TESTING 10 4 1 Checking for gas leaks 10 4 2 Checking the flame appearance 10 5 MAINTENANCE AND UPKEEP 10 5 1 Testing and cleaning 10 5 2 Glass cleaning if optionally installed 11 6 TROUBLESHOOTING 11 7 T...

Страница 3: ...threat of damaging the unit or causing a fire A CO2 or a powder fire extinguisher needs to be placed near the device During the first ignition the GaLiO Insert fireplace needs to be burnt on maximum level for a few hours in order for the elements to acquire correct temperature and for the remains of paint lacquer and lubricant to evaporate Do not move the device while it s working The GaLiO Insert...

Страница 4: ...r recommended 50 mbar Use only regulators complying with the European EN16129 Norm Use only approved and certified gas connection linkage Replace the linkage every 2 years The elastic linkage connecting gas to the fireplace is to be led away from sharp edges and hot surfaces Refrain from bends and twists of the elastic connection on its full length Remember that the LPG bottle should be stored in ...

Страница 5: ... Switch The control unit has standard a cable with a length of 8 meters connection for battery supply and for the controlling NOTE The cables may not be extended Longer cables can pick up environmental signals that can switch the appliance uncontrolled On or Off Determine the location for the control unit Wall Switch Pull the cables through the opening of 50 x 80 mm on the surface on which Wall Sw...

Страница 6: ...ommend to place the battery holder in the same casing located on the Wall Switch rear wall bracket or in a separate casing of the same waterproof class not less than IP64 3 3 Replacing the batteries If the batteries are inserted incorrectly the electronics or drive may be irreparably damaged Only replace the batteries when the appliance has been completely switched off NOTE If the appliance is equ...

Страница 7: ...nikafires com IG0097 02 20 02 2018 7 Unscrew the Wall Switch plate Remove the battery holder Replace 4 pieces of AA LR6 Alkaline long live batteries Replace the battery holder and mount the Wall Switch plate Screw the Wall Switch plate ...

Страница 8: ...ON Appliance Press ON OFF button see Figure 3 until two short beeps confirm the start sequence has begun release button Once pilot ignition is confirmed there is main gas flow Standby Mode Pilot Flame Press and hold small flame button to set appliance at pilot flame To Turn OFF Appliance Press ON OFF button Flame Height Adjustment Press and hold large flame button to increase flame height Press an...

Страница 9: ...figuration the temperature must not exceed 60 C Powered by batteries and or connected to the V module The valve turns to pilot position if the temperature in the receiver is higher than 140 F 60 C NOTE When the receiver temperature is below 140 F 60 C the main burner can be turned ON manually 3 4 2 Automatic Shut Off Low Battery Receiver With low battery power in the receiver the system shuts off ...

Страница 10: ...e placement of decorative stones in such a way for them to be evenly placed on the whole surface of the main burner WARNING Remember not to cover the cover which houses the ignition and the pilot flame with stones Turn on the fireplace and check the appearance of the flame once again 5 MAINTENANCE AND UPKEEP We recommend cleaning the pilot flame and the main burner unit before the device is starte...

Страница 11: ...this issue to service Burner does not ignite 1 The bottle is empty 2 Igniter linkage is not connected 3 No ignition spark 4 The igniter electrode is placed incorrectly opposite the igniter 5 Gas nozzles are blocked 6 Gas linkage is twisted 7 Pressure regulator link is loose 1 Replace Gas Cylinder 2 Connect the igniter linkage 3 Replace igniter 4 Realign electrode and clear any surrounding debris f...

Страница 12: ...sure mbar 30 37 50 20 Gas flow at 15 C and 1013 mbar m3 h 1 0 Gas flow at 15 C and 1013 mbar kg h 0 81 0 93 1 02 Burner pressure at max flame height mbar 22 2 27 3 35 4 11 0 Nozzle of the main burner mm 2 2 2 2 2 2 2 7 Pilot unit G30 ZP2M L G30 ZP2M L G30 ZP2M L G30 ZP2M L Gas control valve Mertik GV 60 Mertik GV 60 Mertik GV 60 Mertik GV 60 Gas linkage Ø9mm Ø9mm Ø9mm External 8 MANUFACTURER S CON...