background image

3.

 

INSTALLATION 

3.1.

 

Box contents 

 

1x complete gas fireplace 

 

1x Touch panel (installed) 

 

1x Remote control (if delivered) 

 

4x AA Batteries  

 

2x AAA Batteries (if remote delivered) 

 

8x bags of decorative stones 

 

1x 4 metre rubber gas linkage 

 installed (only LPG version) 

 

1x pressure regulator (37mbar) 

 installed (only LPG version) 

 

1x installation and user’s manual

 

3.2.

 

Unboxing and installation 

 

The contents of the boxes need to be carefully unwrapped from the foam foil. 

 

Remove the bags with decorative stones from the burner reservoir and place them away from it. 

 

Remove the Styrofoam placed on the unit. 

 

Carefully lift the appliance and pull out the glass shield wrapped in cardboard from the inside of the Galio Star 
Corten. 

 

Check the completeness of the elements with the contents list. 

 

Make sure that the device 

nor its elements weren’t damaged during the t

ransportation (if they were, notify 

the supplier). 

 

Place  Galio  Star  Corten  on  a  flat,  paved  surface  outside  of  the  building,  preferably  on  the  place  of  final 
installation. Leave sufficient space on the side of the appliance where control panel is located (minimum 1 m). 

 

The decorative stones are to be scattered evenly around the reservoir to completely cover the burner of the 
fireplace. 

 

 

WARNING!!!

 

The stones may not cover or be placed inside the device protecting the ignition unit (Picture 2). 

 

 

Picture 2 

 

In the case of Galio Star Corten powered with natural gas, to obtain the optimum image of the flame, cover 
the burner with a single layer of decorative stones leaving some spaces uncovered of approximately every  
2-3 cm (Picture 2). 

 

Picture 3

 

 

If all the points were completed according to the instruction the gas bottle can be now  
connected. 

Содержание G20/G25

Страница 1: ...ight Planika Sp z o o www planikafires com IG0295 00 21 06 2021 1 INSTALLATION and USER S MANUAL Galio Star Corten G20 G25 Natural Gas G30 G31 Propane Butane Propane H1 H2 D1 D2 mm 320 10 595 950 H2 H1 D2 D1 ...

Страница 2: ...ion 10 4 OPERATING INSTRUCTIONS 11 4 1 Setting up signal code 11 4 2 Replacing the batteries 11 4 3 Remote control if delivered 13 4 3 1 Switch the Fire ON and OFF 13 4 3 2 Stand by mode Pilot flame 14 4 3 3 Flame height adjustment 14 4 3 4 Flame height directly to minimum position 15 4 3 5 Flame height directly to maximum position 15 4 3 6 Automatic Turn Down To Pilot 15 4 3 7 Automatic Shut Off ...

Страница 3: ...y additional imitation blocks nor any glowing coal fragments on the burner or in the combustion chamber A CO2 or a powder fire extinguisher needs to be placed near the device During the first ignition the Galio Star Corten fireplace needs to be burnt on maximum level for a few hours in order for the elements to acquire correct temperature and for the remains of paint lacquer and lubricant to evapo...

Страница 4: ...place to allow its immediate turn off During the installation process do not allow an open flame or any ignited object to reach the gas cylinder The gas cylinder should be in a distance not shorter than 1 5 metres away from the Galio Star Corten fireplace Leaks should be found with the use of a cleaning liquid and water If bubbles form on the surface that means that a there s an existing leak Alwa...

Страница 5: ...the elements with the contents list Make sure that the device nor its elements weren t damaged during the transportation if they were notify the supplier Place Galio Star Corten on a flat paved surface outside of the building preferably on the place of final installation Leave sufficient space on the side of the appliance where control panel is located minimum 1 m The decorative stones are to be s...

Страница 6: ...rofessional a company or the gas supplier Before proceeding with the connection of the gas cylinder to the fireplace all activity regarding the correct placement and installation of the Galio Star Corten needs to be already performed Place the gas linkage away from hot or sharp edges and make sure it is not twisted 3 4 1 Natural gas connection First and foremost make sure that the connecting devic...

Страница 7: ...o national standards and norms The Galio Star Corten fireplace can use metal or steel bottles or composite bottles filled with propane butane gas or propane gas This device features a twist on regulator with current pressure of 37 mbar It can be replaced into a regulator with a quick release with pressure regulator of 37 mbar WARNING NEVER use an unstable gas connection or a regulator for other ga...

Страница 8: ... the gas device are closed and if the switch in in the OFF position 4 Fit the connecting nut to the cylinder with the use of a correct wrench or the connecting knob left thread Do not allow the gas bottle connectors to be fastened too tightly 3 Place the quick release regulator on the valve and press it down hard If the switch is correctly turned off you will hear a characteristic click 5 When the...

Страница 9: ...ar Corten put it into the OFF position The main and pilot burner need to be turned off 2 Turn the bottle valve into the OFF position clockwise 2 Turn the switch into the OFF position 3 NEVER DO NOT unmount the regulator or connecting nut when the bottle valve is open 4 TAKE OFF the regulator or the connecting nut with the use of a wrench or a connecting knob 3 Take off the quick release regulator ...

Страница 10: ... Star Corten the OFF position The main burner and the pilot burner need to be turned off 3 Disconnect the regulator from the gas bottle description above 4 Loosen the metal clamp with the use of a screwdriver philips or a flat wrench 5 Move the clamp away from the stub of gas regulator 6 Take off the linkage from the stub of regulator 7 Attach a new linkage on the stub of regulator 8 Move the clam...

Страница 11: ...ld transmitter s signal code before the first use Press the RESET button on the receiver and keep this pressed until 2 beeps are heard Release the RESET button after the second somewhat longer beep Press within 20 seconds the button small flame on the hand held transmitter until 2 short beeps are heard The signal code has now been set up on the receiver If however a single long beep is heard this ...

Страница 12: ...the cover of the battery container with a screwdriver and remove the battery box outside Picture 8 Removing of the battery container Unscrew the cover and replace the batteries in the container WARNING Remember about proper polarization of the batteries Picture 9 Replacing the batteries in the container Screw the cover back and place container back ...

Страница 13: ...eries are not permitted To replace batteries o Open the cover on the back of the remote control o Remove the batteries from the battery compartment o Place two new 1 5V batteries LR03 or AAA type as indicated in the battery compartment o Close the cover 4 3 1 Switch the Fire ON and OFF Before operating make sure MANUAL knob on the GV60 valve is in the ON full counter clockwise position WARNING Whe...

Страница 14: ... may be some temporary problems with switching on the fireplace This is a normal phenomenon associated with the dampening of the ignition element Before switching on the fireplace wait until the ignition element has dried completely You can speed up this process by blowing the pilot flame with compressed air to remove the accumulated moisture The properly fired pilot flame consist of 3 smaller par...

Страница 15: ...ion between handset and receiver for a 3 hour period The fire will continue to function normally when communication is restored Receiver Overheating Powered by mains adapter The valve turns to pilot flame if the receiver temperature is higher than 176 F 80 C If batteries are installed in the receiver in this configuration the temperature must not exceed 60 C Powered by batteries and or connected t...

Страница 16: ...ally behind Wall Switch the battery box can be placed Picture 10 Touch panel To Turn ON Appliance Press ON OFF button see Picture 10 until two short beeps confirm the start sequence has begun release button Once pilot ignition is confirmed there is main gas flow Standby Mode Pilot Flame Press and hold small flame button to set appliance at pilot flame To Turn OFF Appliance Press ON OFF button Flam...

Страница 17: ...ich houses the ignition and the pilot flame with stones Turn on the fireplace and check the appearance of the flame once again 6 MAINTENANCE AND UPKEEP We recommend cleaning the pilot flame and the main burner unit before the device is started again after its been removed from storage during the winter period 6 1 Testing and cleaning Please check and clean if necessary The main burner if necessary...

Страница 18: ...nction 1 Ensure pilot electrode wire is connected 2 Realign electrode and clear any surrounding debris from area 3 Replace Igniter Low efficiency cracking sounds 1 The bottle is empty 2 The nozzles of the burner are blocked 1 Replace Gas Cylinder 2 Unmount the burner clean the nozzle Thumping sounds made by the regulator The cylinder valve has opened rapidly Unfasten the bottle valve slowly A vivi...

Страница 19: ...ically after the warranty period Any damages caused by improper handling storage of poor maintenance incompatible with the conditions laid down in the manual and due to other reasons not due to the fault of the manufacturer will void the warranty In the event of a complaint always contact your dealer Supplier will contact the company Planika if it deems it necessary Factory Warranty is valid for 2...

Страница 20: ...nuals I hereby declare that having read the User s Manual and the Guarantee Conditions Date and legible signature of the Buyer INSTALLER Name Address Tel fax Date of commissioning I hereby declare that the gas fireplace installed by my Company has been installed in accordance with the applicable building regulations and in accordance with the guidelines contained in the Installation and User s Man...

Отзывы: