Planet XGS3-2SFP+ Скачать руководство пользователя страница 2

– 7 –

– 8 –

Figure 2

  Remove the blank bracket

2. Install  the  XGS3-2SFP+  module  by  inserting  it  into  the 

rails  and  sliding  it  in  until  it  stops  (See  Figure  3).  Press 

it  firmly  until  you  feel  the  module  snap  into  place.  Never 
force, twist or bend the optional module.

3. Gently  push  the  thumbscrews  and  turn  clockwise  to 

tighten. Do not over tighten the thumbscrews.

4. Power the Switch and it will automatically detect the new 

module.

AC 100V~

240V 2A

DS PS

-48V ~-60V 2.5A

GND -48V 0V

M1

M2

XGS3-2SFP+

Figure 3

  Insert the XGS3-2SFP+ modules

5. Check  the  LED  on  the  module’s  front  panel  to  verify  that 

if there is a link and a proper connection at the port.

Please  refer  to  the  Switch’s  user’s  manual  for  more  about 
Switch or module’s management.

5. SFP+ Transceiver Installation

The  XGS3-2SFP+  has  two  vacant  10Gb  fiber  transceiver 
slots.  The  procedure  of  installing  the  SFP+  10Gb  fiber 

transceiver is as below:

Installing the SFP+ transceiver

1. Put on an ESD wrist strap (or antistatic gloves)

2. Insert  the  SFP+  transceiver  to  the  guide  rail  inside  the 

XGS3-2SFP+ module. Do not to put the SFP+ transceiver 
up-side-down.

3. Push  the  SFP+  transceiver  along  the  guide  rail  gently 

until  it  comes  into  contact  with  the  front  panel  of  the 
XGS3-2SFP+ module.

AC 100V~

240V 2A

DS PS

-48V ~-60V 2.5A

GND -48V 0V

M1

M2

XGS3-2SFP+

Figure 4

  Plug-in the SFP+ transceiver

Note

The SFP+ 10Gb transceiver is hot-swappable.

Caution!

Do  not  stare  directly  at  the  2  fiber  bore  in  the  SFP+ 
transceiver  when  the  Switch  is  in  operation,  otherwise  the 

laser may hurt your eyes.

Connect the fiber cable

1. Make sure both side of the SFP+ transceiver are with the 

same media type, for example: 10GBase-SR to 10GBase-
SR, 10GBase-LR to 10GBase-LR.

2. Check  the  fiber-optic  cable  type  match  the  SFP+  trans

-

ceiver model.

3. Attach the duplex LC connector on the network cable into 

the SFP+ transceiver.

4. Connect the other end of the cable to a device – switches 

with XFP or SFP+ installed, fiber NIC on a workstation or 

a Media Converter.

5. Check  the  LNK/ACT  LED  of  the  XGS3-2SFP+  module. 

Ensure that the SFP+ transceiver is operating correctly.

– 5 –

– 6 –

Appendix A

Fiber Optical Cable Connection Parameters

The wiring details are as below:

Fiber Optical patch Cables:

Standard

Wavelength

Fiber Type

Cable 

Specification

10GBase-SR

850nm

Multi-mode

50/125μm

10GBase-LR 1310nm

Single mode

9/125μm

 