User’s Manual of WGSD-1022/WGSD-8000
- 206 –
Default Configuration
Flow Control is off.
Command Mode
Interface configuration (Ethernet, port-channel) mode
User Guidelines
Flow Control will operate only if duplex mode is set to FULL. Back Pressure will operate only if duplex mode is set to HALF.
When Flow Control is ON, the head-of-line-blocking mechanism of this port is disabled.
If a link is set to NOT use auto-negotiation, the other side of the link must also be configured to not use auto-negotiation.
To select
auto
, ensure negotiation for Flow Control is enabled.
Example
In the following example, Flow Control is enabled on e5.
Console(config)#
interface ethernet e5
Console(config-if)#
flowcontrol on
5.7.9 mdix
The
mdix
interface configuration command enables automatic crossover on a given interface. To disable automatic crossover,
use the
no
form of this command.
Syntax
mdix {on | auto}
no mdix
on
—Manual mdix
auto
—Auto mdi/mdix
Default Configuration
Automatic crossover is enabled
Command Mode
Interface Configuration (Ethernet) mode
User Guidelines
Mdix Auto :
All possibilities to connect a PC with cross OR normal cables are supported and are automatically detected.
Mdix ON
: It is possible to connect to a PC only with a normal cable and to connect to another switch ONLY with a cross cable.
If MDIX is set to "no mdix", the device works oppostie from the "MDIX On" behavior. It is possible to connect to PC only with
cross cable, and to connect to another switch ONLY with Normal cable
Содержание WGSD-1022
Страница 136: ...User s Manual of WGSD 1022 WGSD 8000 136 ...
Страница 152: ...User s Manual of WGSD 1022 WGSD 8000 152 Figure 4 82 Flash Logs screen ...