4.2 Update 

Procedure 

Users can adjust transmission speeds manually through an 
application called the “E2PROM Programmer” created by 
Infineon. This program can be found on “Utility” directory of 
bundled CD.    Before running this program, please note that 
it is only for the following operation systems: 
1.  Windows 95, 98, NT, Me English version. 
2.  Windows 2000 and XP 
However, Windows 2000 and XP should be configured to 
use English as default language settings for the system.    To 
configure this,   

Windows 2000:

 Click “Start” -> “Settings” -> “Control Panel” 

-> “Regional Options” -> “General” tab.    Click “Set default” 
button and select “English [United States] as default 
language settings. 

Windows XP:

 Click “Start” -> “Settings” -> “Control Panel” -> 

“Regional and Language Options” -> “Advanced” tab.    On 
the ”Language for Non-Unicode programs” list, select 
“English [United States]”. 

 

Below are the procedures to change its speed through 
“E2PROM Programmer”.

 

1. Connect VC-101 console port to a PC COM port. (DB9 

to DB9 Cable) 

2. Launch the “E2Prom Programmer” application. 
3. Select “PEF22822 V2.2” option from the drop-down 

menu. 

4. Press the “Continue” button. 

Содержание VC-1015

Страница 1: ......

Страница 2: ...nt generates uses and can radiate radio frequency energy and if not installed and used in accordance with the Instruction manual may cause harmful interference to radio communications however there is...

Страница 3: ...indicators 13 2 1 2 Power Source 14 2 2 Bottom Panel 14 3 INSTALLING AND USING VDSL CONVERTER 16 3 1 Install the Ethernet Over VDSL Converter 16 3 2 LAN to LAN connection 16 3 3 Connect to Multi Port...

Страница 4: ...4 This page intentionally left blank...

Страница 5: ...onverter is a switching architecture with one RJ45 10 100Mbps Fast Ethernet ports and one RJ11 symmetric Ethernet over VDSL port symmetry means upstream and downstream rate are the same or similar It...

Страница 6: ...the burden on the Internet The converter is plug n play without any software to configure and also fully compliant with all kinds of network protocols Moreover the rich diagnostic LEDs on the front p...

Страница 7: ...7 Drawing 1 LAN to LAN connection Drawing 2 Multi port Master Connection...

Страница 8: ...4 5 5 11 11 and 17 15 Mbps adjustable data rate with R4 5 firmware when VC 101S works with VC 412 only Cisco LRE switch CPE compatible with R4 5 firmware Complies with IEEE802 3 IEEE802 3u and IEEE80...

Страница 9: ...UTP Cat 3 4 5 up to 100m 328ft 100Base TX 2 pair UTP Cat 5 up to 100m 328ft VDSL twisted pair telephone or ISDN wires AWG26 or better up to 5000ft 1 5km Protocols and Standards IEEE 802 3 Ethernet IEE...

Страница 10: ...10...

Страница 11: ...11 This page intentionally left blank...

Страница 12: ...ing connection This section describes the hardware features of these Converters For easier control of the converter familiarize yourself with its display indicators and ports Front panel illustrations...

Страница 13: ...f No error Ethernet Ports On Ethernet link is established LNK Ethernet link Green Off No Ethernet link is established On Full Duplex 1 Blinking Half duplex and Transmission collisions have occurred FD...

Страница 14: ...all the time please consider using UPS Uninterrupted Power Supply for your device It will prevent you from network data loss or network downtime 2 In some area installing a surge suppression device m...

Страница 15: ...15 This page intentionally left blank...

Страница 16: ...e same telephone or ISDN lines Two RJ 11 connectors for VDSL port One for voice device connection like telephone and the other one for network link connection Depending on the quality of telephone lin...

Страница 17: ...phone lines When deciding where to put the converter then you must ensure It is accessible and cables can be connected easily Cabling is away from sources of electrical noise such as radios transmitte...

Страница 18: ...Interface Card NIC via regular Cat 5 cable CN 501 5V 2A POWER SYNC ERR VDSL POTS RESET 10 100 LNK X FDX COL ACT 10 100 Base Tx 1 2 3 4 5 6 7 8 9 8 RJ 11 Phone Jack RJ 11 Line Cord CN 501 RT VDSL Modem...

Страница 19: ...91011 12 A B 12x 6x 8x 2x 9x 3x 10x 4x 11x 5x 7x 1x Ethernet A 12x 6x 8x 2x 9x 3x 10x 4x 11x 5x 7x 1x C CN 501 5V 2A POWER SYNC ERR VDSL POTS RESET 10 100 LNK X FDX COL ACT 10 100 Base Tx 1 2 3 4 5 6...

Страница 20: ...stream Mbps Firmware version Line speed Data rate Line speed Data rate Maximum Distance R2 default 12 5 11 38 12 5 11 38 1 2km R4 18 75 17 06 16 67 15 17 1 05km R4 5 1 56 6 25 12 5 18 75 1 43 5 69 11...

Страница 21: ...uage settings for the system To configure this Windows 2000 Click Start Settings Control Panel Regional Options General tab Click Set default button and select English United States as default languag...

Страница 22: ...firmware file to be upload to the VC 101 Note The firmware file should be placed on directory with only English character 6 Locate and open the corresponding version of firmware file to be uploaded 7...

Страница 23: ...o distance restriction or environment factors II Connect the VC 101M and a PC through console port via console cable DB 9 to DB 9 cable III Launch terminal application and set its settings to Baud Rat...

Страница 24: ...e VC 101M S VII Compare the displayed variables with the variable in the table below to determine your VC 101M S s speed Variables for 11 Mbps upstream 11 Mbps downstream R2 32 24 4F 00 Variables for...

Страница 25: ...more than 1 5km 2 Please note you must use 1 VC 101M and 1 VC 101S connect to each other to make it work SYMPTOM Switch Link Act LED not lit after cable is connected to the port CHECKPOINT 1 Verify u...

Страница 26: ...EM VC101V1...

Отзывы: