Planet PL-501 Скачать руководство пользователя страница 2

Copyright

 

Copyright (C) 2011 PLANET Technology Corp. All rights reserved.  
The products and programs described in this User’s Manual are licensed 
products of PLANET Technology, This User’s Manual contains proprietary 
information protected by copyright, and this User’s Manual and all accompanying 
hardware, software, and documentation are copyrighted.  
No part of this User’s Manual may be copied, photocopied, reproduced, 
translated, or reduced to any electronic medium or machine-readable form by 
any means by electronic or mechanical. Including photocopying, recording, or 
information storage and retrieval systems, for any purpose other than the 
purchaser's personal use, and without the prior express written permission of 
PLANET Technology. 

 

Disclaimer 

PLANET Technology does not warrant that the hardware will work properly in all 
environments and applications, and makes no warranty and representation, 
either implied or expressed, with respect to the quality, performance, 
merchantability, or fitness for a particular purpose. 
PLANET has made every effort to ensure that this User’s Manual is accurate; 
PLANET disclaims liability for any inaccuracies or omissions that may have 
occurred. 
Information in this User’s Manual is subject to change without notice and does 
not represent a commitment on the part of PLANET. PLANET assumes no 
responsibility for any inaccuracies that may be contained in this User’s Manual. 
PLANET makes no commitment to update or keep current the information in this 
User’s Manual, and reserves the right to make improvements to this User’s 
Manual and/or to the products described in this User’s Manual, at any time 
without notice. 
If you find information in this manual that is incorrect, misleading, or incomplete, 
we would appreciate your comments and suggestions. 

 

FCC Compliance Statement 

This equipment has been tested and found to comply with the limits for a Class B 
digital device pursuant to Part 15 of the FCC Rules.  These limits are designed to 
provide reasonable protection against radio interference in a commercial 
environment.  This equipment can generate, use and radiate radio frequency 
energy and, if not installed and used in accordance with the instructions in this 
manual, it may cause harmful interference to radio communications.  Operation 
of this equipment in a residential area is likely to cause interference, in which 
case the user, at his own expense, will b required to take whatever measure are 
necessary to correct the interference. 

 

 

2

Содержание PL-501

Страница 1: ...User s Manual PL 501 200Mbps Powerline Ethernet Bridge...

Страница 2: ...cies or omissions that may have occurred Information in this User s Manual is subject to change without notice and does not represent a commitment on the part of PLANET PLANET assumes no responsibilit...

Страница 3: ...cal and electronic equipment should understand the meaning of the crossed out wheeled bin symbol Do not dispose of WEEE as unsorted municipal waste an h to collect such WEEE s d ave eparately Trademar...

Страница 4: ...CONTENTS 6 1 5 SYSTEM REQUIREMENTS 6 1 6 WIRE DIAGRAM 9 CHAPTER 2 INSTALLING 10 2 1 OVERVIEW 10 2 2 RUNNING THE INSTALLSHIELD WIZARD 10 CHAPTER 3 CONFIGURATION 13 3 1 OVERVIEW 13 3 2 MAIN SCREEN 13 3...

Страница 5: ...rk It is simply by plugging the PL 501 into the wall anywhere in the house or office The 128 Bit AES data encryption improves the security and reliability to protect the data leaked by someone else Cu...

Страница 6: ...ng Storage Temperature 10 70 degree C Storage Relative Humidity 5 95 non condensing Power 100 240V AC 50 60Hz 1 4 Package Contents PL 501 x 1 PL 501 x 2 for PL 501 KIT CD ROM x 1 User s Manual Quick G...

Страница 7: ...ower save mode System is resetting System is in the process of security setup Power Off Power is off Green On The device is connecting to other devices via the Ethernet interface but not communicating...

Страница 8: ...s Link Rate 40 Mbps Red Link Rate 20 Mbps Red Blink When the device is scanning other PLC devices the Data indicator blink quickly Data Off The adapter has not found any other compatible power line de...

Страница 9: ...1 6 Wire Diagram 9...

Страница 10: ...ed Questions section in our Web site 2 2 Running the InstallShield Wizard Please verify that no other Powerline Management Utilities are installed before installing this product If other utilities wer...

Страница 11: ...allows you to change the default directory where the program is installed Or go Back If you don t want to change it click on Next to continue the installation Please click on Next to confirm the inst...

Страница 12: ...Powerline Utility is being installed and please waits for installation This screen shows that the installation was completed successfully Click on Close to exit the wizard 12...

Страница 13: ...twork password All your Powerline devices must use the same network password in order to be connected together 3 2 Main Screen Part 1 Scan a Local Powerline device Double click the PowerPacket Utility...

Страница 14: ...Main tab shows all the other Powerline units on your home network It will represent them by MAC Address and will also show the available bandwidth to each unit Units farther away from another Powerlin...

Страница 15: ...creen you don t have to do this with all units If the problem persists try to move the unit closer to this current unit adjacent plugs on the same wall socket is most preferable If the problem still p...

Страница 16: ...t that is currently connected to this computer This network password encrypts all data that is sent from this unit using 128 bit data encryption standard AES Note Every unit on your home network MUST...

Страница 17: ...ind the DEK Device Encryption Key Key located on the bottom of each device Enter this Key into the Device Password area Click Add This Device Key will then appear in the bottom window Add all the DEK...

Страница 18: ...Note The DEK is unique for EACH Powerline device To use this you will need to input the DEK for each unit 18...

Страница 19: ...l shows technical data concerning software and hardware on the host computer used to communicate over HomePlug It shall include the following Operating System Type Version Host Network Name User Name...

Страница 20: ...ate device last scanned 3 5 Security Button This section describes how to use Security button for configuration in the following situations z Establish a new security network Network AB The procedure...

Страница 21: ...R LEDs start to flash 5 After a few seconds the PWR and HP LEDs should be on The connection of Network AB is success z Establish Powerline c to join an existing network Network AB The procedure is as...

Страница 22: ...sed to clear ALL data and restore ALL settings to the factory default values The procedure is as follows 1 Hold the reset Button down while Power On for a few seconds 2 Release the reset button 3 All...

Страница 23: ...BPSK and ROBO Encryption 128 AES LED Indicators Power Power on and off Ethernet Ethernet link and activity Data PLC link and activity Buttons Reset Restore the default factory settings Security Set th...

Отзывы: