4.2.7.  VLAN Mode (2 modes) 

This menu contains two items for 2  VLAN mode selection:

 

● 

 VLAN is valid for all packets Disable 

● 

 VLAN is valid for broadcast and multicast packets, not for unicast packets. 

● 

 Quit 

 

 

Figure 4-8: VLAN Mode( 2 modes) 

 

4.2.8.  VLAN for CPU (2 VLANs) 

This menu contains two items for 2 VLANs for CPU: 

● 

 Current first VLAN for CPU: VLAN ID 1

Current second 

● 

 VLAN for CPU: None 

● 

Quit 

 

Figure 4-9: VLAN for CPU( 2 VLANs)

 

4.2.9  Secure IP for Telnet and HTTP 

This menu contains seven items for 

Secure IP setting

● 

 Secure IP for Telnet:  Disabled(default value) 

● 

 Secure IP for HTTP:   Disabled (default value) 

● 

 Secure IP 1: 

● 

 Secure IP 2: 

● 

 Secure IP 3: 

● 

 Secure IP 4: 

● 

 Quit 

Содержание MGSW-2402

Страница 1: ...10 100 1000Mbps Intelligent Ethernet Switch MGSW 2402 User s Manaul...

Страница 2: ...is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the Instruction manual may cause harmful...

Страница 3: ...IC ADDRESS 16 3 15 BROADCAST STORM FILTER 17 3 16 PORT MIRRORING 17 3 17 IP CONFIG 18 3 18 SNMP 19 3 19 SAVE REBOOT 19 3 20 UPGRADE 20 4 CONSOLE INTERFACE 22 4 1 CONNECT TO PC 22 4 2 MAIN MENU 22 4 2...

Страница 4: ...telligent Switch Modules and Gigabit 1000Base SX LX Intelligent Fiber Modules With its build in Web based Management managing and configuring the MGSW 2402 Intelligent Switch becomes easier From cabin...

Страница 5: ...MP network management IEEE 802 1Q Tagging VLAN 256 VLAN Group IEEE 802 1D Spanning Tree Protocol STP Port Trunking supported IGMP and Sniffer Port Mirroring supported Port Priority 802 1p TOS Type of...

Страница 6: ...ch Module Gigabit 1000Base SX LX Intelligent Fiber Module 2 1 Front Panel The Front Panel of the MGSW 2402 Intelligent Switch consists of 24x auto sensing 10 100Mbps Ethernet RJ 45 Ports two optional...

Страница 7: ...other port of Switch by following the same process as described in Step2 Notice Cable distance for Switch The cable distance between Ethernet Switch and hub PC should not exceed 100 meter for UTP STP...

Страница 8: ...11 Set Run Unsigned Content to Enable 12 Press OK for all open dialog windows For Internet Explorer 5 1 Click on Tools 2 Pick Internet Options 3 Select the Security tab 4 Select Local Intranet click o...

Страница 9: ...ssigned name of the managed unit System Location The physical location of this managed unit System Contact The contact person for this managed unit System Up Time The time last since the managed unit...

Страница 10: ...the following example 1 port Gigabit 1000Base SX LX Fiber Module and 4 port 100Base FX ST Fiber Module are installed into the Switch Figure 3 3 The Modules Page 3 5 Ports Inside Ports page you can en...

Страница 11: ...will forward this broadcast packet only to those ports belonging to the same VLAN VLAN classification of every packet is done in the following way If the packet is tagged with non zero VLAN id field...

Страница 12: ...nly once to configure the desired VLANs you want Note if you want to set multiple VLANs we suggest that you set Default VLAN ID for each port first in Ports page 3 8 TRUNK Port trunking is the ability...

Страница 13: ...ecalculates the spanning tree topology and activates the standby path Figure 3 8 The STP page If you want to participate in spanning tree have the Enable Spanning Tree Protocol checkbox selected The C...

Страница 14: ...eckbox is uncheck there is no MAC address count restriction for that port Type the number in the Max Allowed MAC Address Count edit for that port The upper bound of this number is the Max Allowed MAC...

Страница 15: ...a low priority 3 12 Port Priority Type of Service Each port can parse the header of an incoming IPv4 header and identify the Type Of Service byte TOS field This is extremely important with the deploym...

Страница 16: ...ntinue to receive the multicast service Figure 3 12 The IGMP page IF you want your switch to support multimedia and IP multicast enable this option default is enabled When this option is enabled this...

Страница 17: ...to unlock this MAC address from that port this MAC address is free again Press Remove All to delete all entries from static address table 3 15 Broadcast Storm Filter Storm Filter can avoid any flooded...

Страница 18: ...ror Target Module and Mirror Target Port choice box Click the corresponding Enabled check box Press Apply button 3 17 IP Config You can change the IP address subnet mask and default gateway of the man...

Страница 19: ...arty s SNMP Simple Network Management Protocol agent Access rights to the SNMP agent are controlled by community strings To set system name system location and system contact you can type the desired...

Страница 20: ...r FTP to download the new version firmware from our website Enter password in the Password edit box Enter the file downloaded in the File Path edit box You can use Browse button to select the file Pre...

Страница 21: ...21...

Страница 22: ...just settings as below 4 2 Main Menu The main menu displays all the sub menus that are available Striking Enter at a highlighted option will confirm the choice of the specified sub menu As shown in Fi...

Страница 23: ...or of this Switch IP Address display and set the IP address of MGSW 2402 Subnet Mask display and set the Subnet Mask of MGSW 2402 Default Gateway display and set the gateway of MGSW 2402 Change User P...

Страница 24: ...or disable VLAN Tagged on each port Default VLAN ID allow set VLAN ID 1 4095 on each port Note set and display the information of each port Quit back to previous menu Figure 4 3 Port Settings 4 2 3 A...

Страница 25: ...Storm Filter This menu contains three items to enable or disable Broadcast Storm Filter Enable Disable Quit Figure 4 6 Broadcast Storm Filter 4 2 6 IGMP This menu contains three items to enable or dis...

Страница 26: ...e 2 modes 4 2 8 VLAN for CPU 2 VLANs This menu contains two items for 2 VLANs for CPU Current first VLAN for CPU VLAN ID 1Current second VLAN for CPU None Quit Figure 4 9 VLAN for CPU 2 VLANs 4 2 9 Se...

Страница 27: ...402 by HTTP enable allow PC of secure IP login in MGSW 2402 4 2 9 3 Secure IP 1 2 3 4 allow to set 4 Secure IP address of 4 PCs Figure 4 10 Secure IP for Telnet and HTTP 4 2 10 Save Current Settings T...

Страница 28: ...Figure 4 12 Factory Default Settings Reboot System 4 2 12 Reboot System This menu provide reboot the Switch Figure 4 13 Reboot System 4 2 13 Quit THIS MENU PROVIDE LOGOUT OUT THE SWITCH Figure 4 14 Q...

Страница 29: ...m a reset When the Boot from NET option is set Bootstrap can start the system with an image residing on a TFTP server on the network In such a setup a console terminal is connected to the console port...

Страница 30: ...ble may be used even when the end station is attached via a patch panel However when attaching another switch or attaching workstations via hubs a crossover cable will need to be used Please see the f...

Страница 31: ...nt RS232 Male connector 1 front Slide in Slot 2 front Indicator PWR LED 1 per unit Diag LED 1 per unit Port LEDs 100M 1 per port LNK ACT 1 per port FDX COL 1 per port Power Input 100 240VAC 50 60Hz En...

Отзывы: