3. Wiring the Power Inputs
The Upper Panel of the
LRP Managed Switch
indicates a DC inlet power socket
and consists of one terminal block connector within 6 contacts. Please follow the
steps below to insert the power wire.
1. Insert positive/negative DC power wires into contacts 1 and 2 for Power 1 or 5,
and 6 for Power 2.
LRP-422CST: DC 48~56V
Input DC 48-56V
DC1
DC2
Fault
Figure 3-1: LRP-422CST Upper Panel
2. Tighten the wire-clamp screws for preventing the wires from loosening.
1 2 3 4 5 6
V1+ V1-
V2+ V2-
Power 1
Power 2
Positive (+) Pin
Negative (-) Pin
LRP-422CST
Pin 1/5
Pin 2/6
Note
The wire gauge for the terminal block should be in the range from
12 to 24 AWG.