12
Forbid to switch on/off the Power DIP during
operation. Otherwise, it will damage your IPOE-
171S and remote device. If you want to switch
the output Voltage DIP, please Plug OUT the
“POE In”
cable and wait for 3 seconds until
the POE LED (Power) is completely OFF.
5.2 4-pin Power Output Terminal Block
From top to down, there are Negative (V-), Negative (V-),
Positive (V+) and Positive (V+), and two sets of DC power
output contact.
Power Output
12V
12V 24V
DC Voltage
24V
V+
V+
V
V
Figure 4:
Terminal Block of IPOE-171S
Note
Two DC outputs are sharing 12V 2A or 24V 1A,
totaling 55 watts DC output power
, which
means that DC1 + DC2 cannot be over the 55
watts DC output power. Otherwise, it might cause
the power output to malfunction or damage.