![Planet IPOE-171-60W Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/planet/ipoe-171-60w/ipoe-171-60w_user-manual_1562742010.webp)
10
3.2 Industrial PoE++ Injector Upper Panel
The upper panel of the IPOE-171 series has one terminal block
connector where there are two DC power inputs.
DC Input:
48-54V , 2A max.
Max. Fault Alarm Loading: 24V, 1A
V1+
V2+
PWR1
PWR2
Alarm
1 2 3 4 5 6
Figure 3:
IPOE-171-60W upper panel.
DC Input:
12-54V , 6A max.
Max. Fault Alarm Loading: 24V, 1A
V1+
V2+
PWR1
PWR2
Alarm
1 2 3 4 5 6
Figure 4:
IPOE-171-95W upper panel.
3.3 Wiring the Power Inputs
The 6-contact terminal block connector on the top panel of the IPOE-
171 series is used for two DC redundant power inputs. Please follow
the steps below to insert the power wire.
Step 1:
Insert Positive/Negative DC power wires into Contacts 1 and 2
for POWER 1, or 5 and 6 for POWER 2.
DC Input:
12-54V , 6A max.
Max. Fault Alarm Loading: 24V, 1A
V1+
V2+
PWR1
PWR2
Alarm
1 2 3 4 5 6
Figure 5:
Power input pins.