8
2. Tighten the wire-clamp screws for preventing the wires from loos-
ening.
1
2
3
4
5
6
V+
V-
V+
V-
Power 1
Power 2
Positive (+) Pin
Negative (-) Pin
IGS-5225 Series
Pin 1/5
Pin 2/6
Note
1. The wire gauge for the terminal block should be in
the range from
12
to
24 AWG
.
2. Please check the wire AWG Ampere specification
before connecting PLANET Industrial Managed Switch.
Caution
PWR1 and PWR2 must provide the
same DC voltage
for power load balance while operating with dual power
input.
3.1 Grounding the Device
Users
MUST
complete grounding wired with the device; otherwise, a
sudden lightning could cause fatal damage to the device.
PWR1
PWR2
Fault
DI1 DO0 DO1
DI0
GND
GND
DC Input:
48-56V , 6A max.
Max. fault loading: 24V, 1A
1 2 3 4 5 6
1 2 3 4 5 6
Earth Ground