Planet IDL-4802 Скачать руководство пользователя страница 6

Safety Instruction

The following is the safety instructions for IP DSLAM before installing.

>>  The  maximum  operating  temperature  of  the  IP  DSLAM  is  65ºC.  Care  must  be 

taken to allow sufficient air circulation or space between units when the IP DSLAM 

is  installed  inside  a  closed  rack  assembly  and  racks  should  safely  support  the 
combined weight of all IP DSLAM.

>>  The  connections  and  equipment  that  supply  power  to  the  IP  DSLAM  should 
be  capable  of  operating  safely  with  the  maximum  power  requirements  of  the  IP 
DSLAM.  In  the  event  of  a  power  overload,  the  supply  circuits  and  supply  wiring 
should not become hazardous.

>>  The  AC  power  cord  must  plug  into  the  right  supply  voltage.  Make  sure  that 
the  supplied  AC  voltage  is  correct  and  stable.  If  the  input  AC  voltage  is  over  10% 
lower than the standard may cause the IP DSLAM to malfunction.

>> Generally, when installed after the final configuration, the product must comply 

with  the  applicable  safety  standards  and  regulatory  requirements  of  the  country  in 
which it is installed. If necessary, consult for technical support.

>>  A  rare  condition  can  create  a  voltage  potential  between  the  earth  grounds  of 
two or more buildings. If products installed in separate building are interconnected, 

the voltage potential can cause a hazardous condition. Consult a qualified electrical 

consultant  to  determine  whether  or  not  this  phenomenon  exists  and,  if  necessary, 
implement  corrective  action  before  interconnecting  the  products.  If  the  equipment 
is to be used with telecommunications circuit, take the following precautions:

-  Never install telephone wiring during a lightning storm.

-  Never  install  telephone  jacks  in  wet  location  unless  the  jack  is  specially  - 

designed for wet location.

-  Never  touch  un-insulated  telephone  wires  or  terminals  unless  the  telephone  line 

has been disconnected at the network interface.

-  Caution when installing or modifying telephone lines (other than a cordless tele-

phone)  during  an  electrical  storm.  There  is  a  remote  risk  of  electric  shock  from 
lightning.

-  Do  not  use  a  telephone  or  other  equipment  connected  to  telephone  lines  to 

report a gas leak in the vicinity of the leak.

Содержание IDL-4802

Страница 1: ...48 Port ADSL 2 2 IP DSLAM IDL 4802 IDL 4802 48 Quick Installation Guide ...

Страница 2: ...are Installation 7 1 Power and Ground Connections 7 2 FAN Cable Connection 9 3 ADSL and POTS Connections 9 4 Uplink Interfaces Connections 10 5 Management Port Connection 11 6 Console Port Connection 11 7 Housekeeping Connection 11 WEB Configuration 13 Further information 19 ...

Страница 3: ...n x 1 IDL 4802 48 IDL 4802 48Unit x 1 DC Power Terminal Block x 1 CD x 1 Quick Installation Guide x 1 2 Meter Telco 50 Cable x 4 Console Cable x 1 Rack mounting Ear x 2 Screw Package x 2 Connect Tenon x 4 RJ 45 Cable for Fan x 1 If any of above items are damaged or missing please contact your dealer immediately Note Using a power supply with a different voltage rating will damage and void the warr...

Страница 4: ...eeping inputs and one alarm contact output Console RS 232 port for system configuration and maintenance 9600 8 N 1 RST A hidden reset button for hardware resetting ACO Alarm Cut Off MGMT Ethernet Port connected to LAN for providing system out band Telnet control interface such as system monitor control or software upgrade Uplink 1 2 Gigabit Ethernet electrical trunk ports SFP 1 2 Gigabit Ethernet ...

Страница 5: ...mit receive data SYS Green Normal Operation Red Self test fail ALM Green Normal Operation Red To indicate the system alarm status DSL status Green On ADSL Port is activated and linked Off ADSL Port is Disabled Flash ADSL Port is activated but not linked Rear Panel The rear panels are shown below IDL 4802 IDL 4802 48 Port Definition Port Description AC PWR AC Power cord plug in 100 240VAC is allowe...

Страница 6: ...ory requirements of the country in which it is installed If necessary consult for technical support A rare condition can create a voltage potential between the earth grounds of two or more buildings If products installed in separate building are interconnected the voltage potential can cause a hazardous condition Consult a qualified electrical consultant to determine whether or not this phenomenon...

Страница 7: ...el as below figure and plug the cord into the external power source The voltage must be 100 to 240V AC With IDL 4802 48 the DC power interface is a 4 pin terminal block with polarity signs on the front panel as below figure It can be powered from two 48V DC power supply The DC power connector is a 4P terminal block 2P is for accommodating one DC power input and other 2P is for accommodating anothe...

Страница 8: ...recommended to connect the grounding screw to CO GND using 14 or 12 AWG wire gauge conductor In Remote Cabinet The IDL 4802 should be grounded by connecting a 14 or 12 AWG conductor between the grounding screw on the rear panel of the DSLAM refer to below figure and the earth ground or main grounding bar The resistance between the chassis and the grounding bar should be less than 25 Ohm Grounding ...

Страница 9: ... POTS Connections The IDL 4802 supports 48 ports ADSL subscribers per box There are four RJ 21 50 pin female connectors on the front panel of the system Two for ADSL lines and two for POTS interfaces To connect the subscriber lines use cables with the RJ 21 50 pin male connectors When installing just plug the end of cable with connector into the LINE and PHONE connectors on the front panel The oth...

Страница 10: ...faces When both electrical and optical ports are connected system will automatically select the interface according to the priority setting Fiber first or Copper first SFP Mini GBIC Prepare a proper SFP module and install it into the optical trunk port Then you can connect fiber optics cabling that uses LC connectors or SC connectors with the use of an optional SC to LC adapter to the fiber optics...

Страница 11: ...onnect the host PC to the console port a RJ45 male connector to RS232 DB9 female connector cable is required The RJ45 connector of the cable is connected to the COM port of the DSLAM the DB9 connector of the cable is connected to the PC COM port 7 Housekeeping Connection The IDL 4802 equips with a RJ 50 port HK on the front panel to provide four housekeeping inputs and one alarm contact output Gen...

Страница 12: ...s don t need to feed 3 3v power into the circuit As to the alarm output there is a relay between ALMOUT and ALMCOM to control the status of the loop to be OPEN or CLOSE to the alarm equipment close between ALMOUT and ALMCOM for alarm open if no alarm HK Port RJ 50 pin assignment Operation diagram of Housekeeping Inputs and Alarm Contact Output ...

Страница 13: ...figure the IDL 4802 please ensure as below Set your computer s IP with the same network segment of the IP DSLAM For example IDL 4802 default MGMT IP is 192 168 1 1 255 255 255 0 Then you can set computer s IP to 192 168 1 x 255 255 255 0 The range for x is from 2 to 253 Step 1 Using your WEB Browser Open web browser and type http 192 168 1 1 in the browser s address box This IP is the default MGMT...

Страница 14: ...gin the IDL 4802 A login page will appear Please type your username password and click Sign in The default username password is admin admin After you login the IDL 4802 you will see the system information as below ...

Страница 15: ...L PVC Go to Bridge Ë Interface Setup Ë ADSL PVC setting screen select the ADSL port and click Create to apply the PVC settings For example create PVC 1 to Port 1 The default VPI VCI is 0 35 You can see the Port has been created ...

Страница 16: ...16 Step 4 Enable the ADSL Port Service Go to System Ë ADSL Port Service setting screen select the ADSL port and Admin is ON Click Modify to make this Port is ON You can see the Admin status became to ON ...

Страница 17: ... Panel and configure it the VPI VCI value must be the same with IDL 4802 After finish setting the CPE will establish the ADSL connection with IDL 4802 You can check the connection status as below figure The Current Status is ON Now the clients can access to Internet through IDL 4802 ...

Страница 18: ...tings will be lost if you power off IDL 4802 Go to Maintenance Ë Database setting screen select the D Save Running Config to Flash System Config There are two partitions on flash select your Partition which you want to save and click Write Running The configuration will save to the Flash Note Default Partition is Partition1 ...

Страница 19: ...Further information For further detail configurations and information can be found in the user s manual CD If you have any other questions please contact the local dealer where you purchasing this product ...

Страница 20: ...This page is intentionally left blank ...

Отзывы: