background image

11

6. Getting Started with VCOM Utility

With Industrial Serial Server’s 

VCOM

 administration utility, you can 

easily  install  and  configure  one  or  multiple  ICS  serial  device  servers 

over the network from a remote location. There are several functions 

to configure Industrial Serial Server:

 

Searching device

 

Creating virtual COM port

 

Firmware upgrade

 

Importing or exporting file

PC

COM1 (Port1)
COM2 (Port2)

Ethernet

VCOM

Serial bus

Serial Device 2

Serial Device 1

Serial bus

6.1  Installation of VCOM Utility

The ICS serial VCOM Utility can be downloaded from PLANET Web site. 
Please locate and run the setup program 

“vspsetup.exe”

 and follow 

the on-screen instructions.

download link: https://www.planet.com.tw/en/support/downloads?&met
hod=keyword&keyword=ICS-2&view=6#list

After installing, rebooting your workstation/PC is required.

Note

If you have difficulty in downloading or executing VCOM 
Utility, turn off the firewall and anti-virus software first.

Содержание ICS-2100T

Страница 1: ...Industrial 1 2 4 port RS232 422 485 Serial Device Server Series ICS 2100T ICS 2105AT ICS 2200T ICS 2400T Quick Installation Guide ...

Страница 2: ...agement 8 4 2 Logging in to the Industrial Serial Server 8 5 Remote Telnet Login 10 5 1 Logging in to the Remote Command Line Interface 10 6 Getting Started with VCOM Utility 11 6 1 Installation of VCOM Utility 11 6 2 Searching Serial Device Server 12 6 3 Serial Server Login 12 6 4 Serial Server Setting 13 6 5 COM Port Mapping 14 7 Recovering Back to Default Configuration 15 8 Customer Support 16 ...

Страница 3: ... x 100FX SFP ICS 2200T 2 x DB9 2 x 10 100TX RJ45 DC 12 48V ICS 2400T 4 x DB9 Industrial Serial Server is used as an alternative name in this Quick Installation Guide Open the box of the Industrial Serial Server and carefully unpack it The box should contain the following items The Industrial Serial Server x 1 Quick Installation Guide x 1 Wall Mounting Kit x 1 Dust Cap RJ45 SFP DIN rail Bracket w S...

Страница 4: ...with Ethernet NIC Network Interface Card Network cables Use standard network UTP cables with RJ45 connectors Use standard network UTP cables with RJ45 Use Multi mode or Single mode fiber patch cord with LC connector and 100BASE FX SFP transceiver ICS 2105AT only The above PC is installed with Web browser Note It is recommended to use Internet Explorer 8 0 or above to access the Industrial Serial S...

Страница 5: ...10 100TX RS232 ICS 2100T TxD RxD RS422 485 PWR1 PWR2 Fault Reset LNK ACT Rx Tx 100FX SFP RS232 ICS 2105AT TxD RxD RS422 485 PWR1 PWR2 Fault SYS E2 E1 LNK ACT LNK ACT Rx Tx Rx Tx P1 P2 RS232 422 485 P1 P2 ICS 2400T E2 E1 P1 P3 PWR1 PWR2 I O Fault P1 Rx Tx Rx Tx Rx Tx Rx Tx SYS LNK ACT LNK ACT P3 P2 P4 P2 RS232 422 485 P4 ...

Страница 6: ...6 for Power 2 Figures 3 1 to 3 3 show PWR1 and PWR2 of the Industrial Serial Server ICS 2100T ICS 2105AT 9 48V DC or 24V AC V1 V2 V2 PWR1 PWR2 Fault Max fault loading 24V 1A DC Input 9 48V 1A max AC Input 24V 0 5A max 1 2 3 4 5 6 Figure 3 1 ICS 2100T ICS 2105AT Upper Panel ICS 2200T 12 48V DC V1 V1 V2 V2 PWR1 PWR2 Fault DC Input 12 48V 1Amax 1 2 3 4 5 6 Figure 3 2 ICS 2200T Upper Panel 1A 24V V1 V...

Страница 7: ...reventing the wires from loos ening 1 2 3 4 5 6 V1 V1 V2 V2 Power 1 Fault Power 2 Figure 3 4 PWR1 PWR2 Pins of Terminal Block Note The wire gauge for the terminal block should be in the range from 12 to 24 AWG 3 3 Serial Port PIN Assignment ...

Страница 8: ... the default subnet mask is 255 255 255 0 Ethernet PC Workstation with Web Browser IP Address 192 168 0 x RJ45 UTP Cable ICS Serial Device Server IP Address 192 168 0 100 Figure 4 1 IP Management Diagram 4 2 Logging in to the Industrial Serial Server 1 Use Internet Explorer 8 0 or above for Web browser and enter IP address http 192 168 0 100 the factory default IP address to access the Web interfa...

Страница 9: ...eb page lets you access all the functions and statuses the Industrial Serial Server provides Now you can use the Web management interface to continue the Serial Server management Please refer to the user manual for more Note 1 For security reason please change and memorize the new password after this first setup 2 Only accept command in lowercase letter under web interface ...

Страница 10: ...sks for user name and password for remote login when using Telnet please use the following default IP address username and password for the first time login Default IP Address 192 168 0 100 Default Username admin Default Password admin You will be presented with a text menu displaying the Industrial Serial Server s general settings which you will be able to view and modify Please refer to User Man...

Страница 11: ...porting file PC COM1 Port1 COM2 Port2 Ethernet VCOM Serial bus Serial Device 2 Serial Device 1 Serial bus 6 1 Installation of VCOM Utility The ICS serial VCOM Utility can be downloaded from PLANET Web site Please locate and run the setup program vspsetup exe and follow the on screen instructions download link https www planet com tw en support downloads met hod keyword keyword ICS 2 view 6 list Af...

Страница 12: ...o network as shown below 6 3 Serial Server Login The ICS Serial Server is password protected so user can t modify any settings The user must first log in the ICS serials if the password is correct the status will become Logged in On the contrary if the password is incorrect the status will pop up an error window ...

Страница 13: ...gs to open the target Industrial Serial Server s configuration window Parameters are grouped into tables Click OK to implement changes Please refer to user manual for a description of all functional properties for the Industrial Serial Server ...

Страница 14: ...oft Windows XP and other platforms Adding COM If your Serial Server has been found select it in order to add it to the COM mapping list Click OK to take effect COM Mapping Settings Click Modify COM to configure Serial Server s serial COM port User can manually assign COM number to the ICS serial Serial Server After that user can click the OK button and finally press the OK button to take effect ...

Страница 15: ... 5 seconds After the device is rebooted you can log in the management Web interface within the same subnet of 192 168 0 xx and default password Be noted that all the previous setups will be disappeared after the factory default reset is made PWR1 PWR2 Fault Reset LNK ACT Rx Tx 10 100TX PWR1 PWR2 Fault Reset LNK ACT Rx Tx 100FX SFP Figure7 1 ICS 2100T ICS 2105AT Hardware based Reset Button System R...

Страница 16: ... support faq Switch support team mail address support planet com tw ICS 210x 220x series User s Manual https www planet com tw en support download php method keyword keyword ICS view 3 page 1 list Please select your Industrial Serial Server model from the Product Model drop down menu Copyright PLANET Technology Corp 2020 Contents are subject to revision without prior notice PLANET is a registered ...

Отзывы: