HD Ultra-mini Bullet IR IP Camera
ICA-3110
Schedule
After complete the schedule setup, the camera data will be
recorded according to the schedule setup.
Snapshot
After enable the snapshot function, user can select the storage
position of snapshot file, the interval time of snapshot and the
reserved file name of snapshot.
Interval
The interval between two snapshots.
3.8.3 I/O Setting
The ICA-
311
0 supports 1 input/1 output. When input is triggered, it can send the video to some
specific mail addresses, transmit the video to remote ftp server, and trigger the relay and
SAMBA.
Alarm Input Setting
The GPIO I/O port input activates related action when I/O input
is triggered.
Interval
For example, if you select "10 sec" here, once the motion is
detected and action is triggered, it cannot be triggered again
within 10 seconds.
Based on the
schedule
When the option box is ticked, only during the selected
scheduled time the I/O is enabled. That is, for example, the
11th hour of Monday has not been colored in the scheduled
table, then no action will be triggered even the camera detects
input signal during 11:00~12:00 on Monday.
GPIO Output Setting
The GPIO I/O port output activates On/Off Switch, Slide Switch
or Pan/Tilt Module for use with relay box.
On Off Switch
The camera triggers the external devise and lasts for 10
seconds. You can turn off the alarm manually by clicking "off" at
the right bottom of the live video page.
Time Switch
The camera triggers the external device and lasts for certain of
time according to the interval setting, and the user is not
allowed to break off the alarm manually.
Please connect to propriety relay box to reduce the risk of electric shock and
damage.