Connect the Fiber Cable
1. Insert the duplex LC connector into the SFP transceiver.
2. Connect the other end of the cable to a device with SFP transceiver installed.
3. Check the LNK/ACT LED of the SFP slot on the front of the 802.3at PoE+
Switch. Ensure that the SFP transceiver is operating correctly.
Remove the Transceiver Module
1. Make sure there is no network activity anymore.
2. Remove the Fiber-Optic Cable gently.
3. Lift up the lever of the MGB module and turn it to a horizontal position.
4. Pull out the module gently through the lever, as the Figure 3-5 shows.
MGB-SX/LX
1
2
Figure 3-5:
How to Pull Out the SFP Transceiver
Note
Never pull out the module without lifting up the lever of the
module and turning it to a horizontal position. Directly pulling out
the module could damage the module and the SFP module slot of
the 802.3at PoE+ Switch.