Planet FT-722 Скачать руководство пользователя страница 3

 

 

1

FCC Warning 

This equipment has been tested and found to comply with the 
regulations for a Class A digital device, pursuant to Part 15 of 
the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference when the 
equipment is operated in a commercial environment. This 
equipment generates, uses, and can radiate radio frequency 
energy and, if not installed and used in accordance with this 
user

s guide, may cause harmful interference to radio 

communications. Operation of this equipment in a residential 
area is likely to cause harmful interference, in which case the 
user will be required to correct the interference at his own 
expense. 

CE Mark Warning 

This is a Class A product. In a domestic environment, this 
product may cause radio interference, in which case the user 
may be required to take adequate measures. 

Revision 

User's manual for PLANET Fast Ethernet Converter  

Model: FT-722 
Rev 1.0

 (March.2004) 

Part No.

 2010-000030-000 

Содержание FT-722

Страница 1: ...Fast Ethernet Media Converter 100Base FX Multi mode to Single mode...

Страница 2: ...se PLANET has made every effort to ensure that this User s Manual is accurate PLANET disclaims liability for any inaccuracies or omissions that may have occurred Information in this User s Manual is s...

Страница 3: ...installed and used in accordance with this user s guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interferenc...

Страница 4: ...les representative for more about the 19 media chassis 2 Model List Your Fast Ethernet Converter comes with one of the following models FT 722Sxx two on board SC fiber connectors Sxx represents Single...

Страница 5: ...t single mode on the right and three LED indicators PWR RX Multi Mode Single Mode TX RX TX Fast Ethernet Converter LNK ACT Right View One DIP switch for Link Fault Pass Through LFP feature ON to turn...

Страница 6: ...22 and verify that the Power LED lights up Turn on the power of the device station the LNK ACT LEDs should light when all cables are attached 100Base FX Multi mode Fiber Network FT 722 100Base FX Sing...

Страница 7: ...be within 512bit time in segment To extend the distance you may use switch to break up a collision domain and extend the distance The limitations are as below Duplex Connection Limitation max Multi Mo...

Страница 8: ...on 26 x 70 x 97mm HxWxD Cable Fiber MM 50 125 m or 62 5 125 m optic fiber Fiber SM 8 3 125 8 7 125 9 125 m optic fiber Connecting to Router Bridge or Switch Hub please refer to the device s Technical...

Отзывы: