4.2 Link Loss Return (LLR) 

The fiber ports of FST-81x have been designed with an LLR function for troubleshooting a remote connection. LLR works 
in conjunction with LLCF. 

When LLR is enabled*, the port’s transmitter shuts down when its receiver fails to detect a valid receive link. LLR should 
only be enabled on one end of the link and is typically enabled on either the unmanaged or remote device. 

The diagram below shows a typical network configuration with a good link status using FST-81x for remote connectivity. 
Note that LLR and LLCF are enabled as indicated in the diagram. 

 

Management  Switch/Hub         Media                           Media               Switch/Hub   Management 

Station           w/SNMP          Converter               Converter            w/SNMP     Station 

    

 

 

 

 

 LED lit = established link    

 LED unlit = no link 

 

If one of the optical conductors is bad (as shown in the diagram box below), the converter with LLR enabled will return a 
no-link condition to its link partner. With LLCF also enabled, the no-link condition is carried forward to the switch/hub where 
a trap is generated to the management station, and the administrator can then determine the source of the loss. 

 

Management Switch/Hub    Media                        Media        Switch/Hub Management

Station           w/SNMP        Converter                  Converter         w/SNMP        Station

 

 

 

 

 

 LED lit = established link    

 LED unlit = no link 

#

Notice: 

1. The FST-81x is shipped with the default LFP (LLCF/LLR) function disable. This feature can also be turned on on-pu 

pose. If you are familiar with the network installation and for diagnostic purpose (i.e. check which end is broken), you 
can turn it on and the converter will take effect immediately. Otherwise, please remain it in the default position. 

2. LLR must NOT be active on both ends of a configuration. If it is, the link can never be established. 

 

LLCF is ON

 

LLCF is ON

Fiber 

Cable 

 

LLCF is ON

 

LLCF is ON

Port 2

Broken 

Fiber

Port 1 

Link Loss Carried Forward

Link Loss Carried Forward

Link Loss Returned 

Содержание FST-811

Страница 1: ...User s Manual FST 811 FST 812 FST 812S15 812S35 812S50 FST 815A FST 816A20 816B20 10 100Base TX to 100Base FX Smart Media Converter 1...

Страница 2: ...Warning This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection...

Страница 3: ...MR MC 1610MR SERIES CHASSIS INSTALLATION 10 2 3 REAL ETHERNET ENVIRONMENT APPLICATION 11 3 MANAGE THE MEDIA CONVERTER 12 3 1 DIP SWITCH CONFIGURATION 12 3 2 MANAGED MEDIA CONVERTER MODULE THROUGH MC 1...

Страница 4: ...trol function allows FST 81x supported routers and servers to directly connect to FST 81x for fast reliable data transfer The Link Loss Carry Forward LLCF function works with Link Loss Return LLR to d...

Страница 5: ...anagement Provides DIP switch for Flow control Disable Enable and LFP function Disable Enable setting Manageable through Web Smart Managed Media Converter Chassis System MC 1600MR MC 1610MR series Ban...

Страница 6: ...FX 50 125 m or 62 5 125 m multi mode fiber cable up to 2km 9 125 m single mode cable provide long distance for 2 15 20 35 40 50 60km Maximum Cable dis tance MM 2km MM 2km SM 60km MFB F60 SM 15km SM 3...

Страница 7: ...connector vary by model and six LED indicators Left View there is one DC jack for DC 5V power adapter Figure 1 FST 811 Outlook Fast Ethernet Bridge 10 100Base TX to 100Base FX 5V DC Fast Ethernet Bri...

Страница 8: ...link through that port is successfully established Lights Off The link through that port is not established TP LINK ACT Green Lights Blinking Data transmitting or receiving on that port Lights On The...

Страница 9: ...ation in a network to which the FST 81x will be attached Ensure that there is no activity in the network Attach fiber cable from the FST 81x to the fiber network TX RX must be paired at both ends Atta...

Страница 10: ...y expansion slot on the front of the Media Converter Chassis The FST 81x Media Converter board can be installed in any expansion slot Step 3 Slide the FST 81x Media Converter board into the expansion...

Страница 11: ...fferent network applications It is very flexible for the FST 81x working as a standalone device or being installed in the central Web Smart Managed Media Converter Chassis for centralized management W...

Страница 12: ...guration The FST 81x provide DIP switch to setting Flow control Disable Enable and LFP function Disable Enable Please refer to the table below for more detail decription Notice 1 After change the DIP...

Страница 13: ...g of FST 81x such as device Disable Enable LFP Disable Enable TP AN Mode Auto negotiation Force speed 10 100Mbps duplex mode Half Full duplex mode Flow control Disable Enable Item Description Device T...

Страница 14: ...P Disable Enable TP AN Mode Auto negotiation Manual speed 10 100Mbps duplex mode Half Full duplex mode Flow control Disable Enable Item Description Device To enable or disable per FST 81x Converter bo...

Страница 15: ...ansmit receive bandwidth on TP Fiber port of FST 81x Item Description Ingress Rate Limit Define receive rate for bandwidth control from TP and Fiber ports of FST 81x Egress Shaping Define transmit rat...

Страница 16: ...link signal until they receive a link signal from the opposite port The diagram below shows a typical network configuration with a good link status using FST 81x for remote connectivity Note that LLC...

Страница 17: ...h LLR enabled will return a no link condition to its link partner With LLCF also enabled the no link condition is carried forward to the switch hub where a trap is generated to the management station...

Страница 18: ...accept Auto negotiation 10 100Mbps TP Port speed from various devices 10 100Base TX port link LED is lit but the traffic is irregular Solution 1 Check that the attached device is not set to dedicate f...

Страница 19: ...Not used 6 Rx receive Tx transmit 7 8 Not used A 2 RJ 45 cable pin assignment The standard RJ 45 receptacle connector There are 8 wires on a standard UTP STP cable and each wire is color coded The fo...

Страница 20: ...MM Half Node to Node Node to Switch 412 meters MM Full Node to Node Node to Switch 2 kilometers Single Mode Converters FST 81xynn x 2 6 y S A B nn km SM Full Node to Node Node to Switch Depends on mo...

Страница 21: ...tic Compatibility Directive on 2004 108 EC For the evaluation regarding the EMC the following standards were applied Emission EN 55022 2006 Class B Flicker EN 61000 3 3 1995 A1 2001 Immunity EN 55024...

Отзывы: