INSTALLATION:
The Planet Model ULED arm is designed to be mounted above the immediate work area. Standard mounting fi xtures for Planet Model ULED are:
Ceiling Mount & Wall Mount (specialised mountings are available on application). In all cases the suggested mounting height (measured at swivel
head) is two metres from fl oor level. (refer Fig 1)
To ensure correct balance of the Model ULED movement the lamp must be mounted with the stem, around which it rotates, vertical at all
times.
(refer Fig 1)
WARNING
The qualifi ed electrician who is responsible for the installation of the ULED must include an isolation switch( all -pole discon-
nection ) in the fi xed wiring of the ULED and a cable tie near the terminal block of the primary(240V) wiring (Phase and Neutral) to secure the
cables.
Figures 2 - 4 Refers to wall mount options, Figures 6 - 8 Refers to ceiling mount options, Figures 9 - 11 Refers to maintenance procedures
5.0 WALL MOUNT:
WARNING
Ensure before commencing the installation, that the MAINS power circuit is isolated (off).
CHECK AND ENSURE THE FOLLOWING BEFORE COMMENCING INSTALLATION:
•
You have the appropriate mounting template.
•
You have appropriate tools for the job.
•
Confi rmed mains cable entry is located appropriately.
•
The mounting structure is suitable.
•
The structural loadings and approx product weights (refer Fig12)
•
You have appropriate fi xing attachments. e.g. Dyna bolts, large screws
5.1.0 Using appropriate wall template (template 1) mark mounting holes and mains cable entry. Make sure the bottom of the template
wall mount is 2055mm from the fl oor to maintain 2000mm clearance at the bottom of the swivel. (ref Fig 1)
5.2.0 Drill 4 mounting holes as shown on template 1.
Fig: 2
Fig: 10
Fig: 11
Depress button to
remove or replace light head
Lock Nut
left hand
(heavy) spring tube
Spring tension nut
WARNING
UNDER NO CIRCUMSTANCES SHOULD THE
SPRING TENSION NUTS (TWO) BE COMPLETELY UNDONE
Classifi cation: Non invasive medical